Laserfiche WebLink
STRUCTURAL NOTES:- CL POLE & SHAFT SPLICE LENGTH <br /> 1. CODES AND STANDARDS: 7. EXCAVATION, SHORING AND BACKFILL: CL POLE & SHAFT 2'-6° 2'-6" OVERLAP, TYP <br /> ALL MATERIALS, WORKMANSHIP, DESIGN AND CONSTRUCTION A. INSTALL AND SHORE EXCAVATION AS NECESSARY TO FOR POLE DETAILS SEE 4'-0" 4'-0" <br /> SHALL CONFORM TO THE DRAWINGS AND THE INTERNATIONAL PROTECT WORKERS, UTILITIES, PAVEMENT AND OTHER ELECTRICAL DRAWINGS 1" CHAMFER ALL (6) #6 L (3 EQUALLY <br /> BUILDING CODE (IBC), 2018 EDITION, WITH CITY OF EVERETT IMPROVEMENTS AGAINST LOSS OF GROUND, ROCKS, EXPOSED EDGES SPACED ON EACH <br /> AMENDMENTS, AND THE PROJECT SPECIFICATIONS. GRAVELS OR CAVING EMBANKMENTS. BACKFILL AND Q SIDE OF ELEC. <br /> COMPACT WITH NATIVE SOIL TO SUBGRADE ELEVATION NO CONDUITS). <br /> 2. DESIGN LOADS SOONER THAN 3 DAYS AFTER COMPLETION OF v= <br /> A. DESIGN LOAD CRITERIA FOR LOW-MAST AND HIGH-MAST FOUNDATION. LOOSE MATERIAL SHALL BE REMOVED FROM SIZE AND PATTERN OF <br /> POLES: THE BOTTOM OF THE SHAFT PRIOR TO CONCRETE ANCHOR BOLTS PER N <br /> EARTHQUAKE LOADS: PER IBC 2018 PLACEMENT. i - - \ MANUFACTURER'S o <br /> WIND LOADS: 98 MPH; EXPOSURE D; IMPORTANCE o V \ #4 VERT TIES AT 12" OC <br /> a RECOMMENDATIONS u <br /> FACTOR OF 1.0 B. MATERIAL REMOVED DURING EXCAVATIONS AND DRILLING <br /> ULTIMATE BASE REACTIONS FOR POLES SHALL BE MAY BE CONTAMINATED SOIL. SEE SPECIFICATIONS FOR - - - <br /> CALCULATED PER AASHTO _RFD LOAD COMBINATIONS. SOIL HANDLING AND DISPOSAL REQUIREMENTS. l <br /> B. ULTIMATE POLE BASE REACTION FOR THE HIGH-MAST POLE C. SHAFT INSTALLATION SHALL BE PERFORMED UTILIZING \ / <br /> FOUNDATION: TEMPORARY CASING. PERMANENT CASING MAY ALSO BE \rttt A (4) #4 HORIZ TIES <br /> OVERTURNING MOMENT M = 50 KIP*FT USED IF APPROVED BY THE ENGINEER PRIOR TO BID. 51.1 51.1 N 3" u <br /> DOWNLOAD N = 2.5 KIPS THE HOLE SHALL BE KEPT DRY AND FREE OF MUD �w CLR <br /> SHEAR V = 1.1 KIPS PRIOR TO REINFORCING CAGE INSTALLATION AND DURING POLE LOCATION WORK LI ELEC CONDUITS, SEE <br /> CONCRETE PLACEMENT. SEE SPECIFICATIONS FOR SOIL SPLICE <br /> POINT SHOWN ON ELEC DWGS FOR <br /> C. ULTIMATE POLE BASE REACTION FOR THE LOW-MAST POLE DISPOSAL AND DEWATERING REQUIREMENTS. o 0 0 0 0 0 o I LENGTH <br /> FOUNDATION: CIVIL DRAWINGS SIZE AND QUANTITY \\ °o°o°o 0 0_0 \%J1 OVERLAP, <br /> //\ 000000 <br /> OVERTURNING MOMENT M = 23 KIP-FT 8. SPECIAL INSPECTIONS: M 1 L\\�\°o°0 000 // TYP <br /> DOWNLOAD N = 1.0 KIP A. A QUALIFIED INSPECTOR SHALL PERFORM CONTINUOUS HIGH-MAST POLE FOUNDATION P LAN ------- <br /> SHEAR V = 0.4 KIPS INSPECTION ON THE FOLLOWING SHAFT AND <br /> MISCELLANEOUS FOUNDATION ITEMS: SCALE: 1/2" = 1'-0" \\ <br /> 3. GEOTECHNICAL DESIGN CRITERIA: <br /> °. ANCHOR BOLTS AND INSERTS <br /> FOUNDATIONS AND RETAINING WALL DESIGN IS IN ACCORDANCE b. PREPARATION OF TEST SPECIMENS <br /> WITH LANDAU ASSOCIATES REPORT DATED DUNE 2021. C. CONCRETE PLACEMENT ULTIMATE BASE REACTION LOADS TOP OF SHAFT FLEXIBLE COUPLER <br /> (M, N, AND V) SEE NOTE 2.B�M 2" NON-SHRINK SEE SPECIFICATIONS <br /> 4. GENERAL: d. DRILLED SHAFTS (BY PROJECT GEOTECHNICAL r <br /> A. THIS DRAWING SHALL BE USED IN CONJUNCTION WITH ENGINEER) GROUT PAD ELEC CONDUITS, <br /> ELECTRICAL AND CIVIL DRAWINGS FOR BIDDING AND POLE BASE PLATE AND ANCHOR SEE ELEC DWGS FOR DRILLED <br /> CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS B. A QUALIFIED INSPECTOR SHALL PERFORM PERIODIC BOLTS ARE CONTRACTOR V SHAFT REINF SEE <br /> DESIGNED AND SUPPLIED. SEE B .S 51.1 <br /> AND CONDITIONS FOR COMPATIBILITY PRIOR TO COMMENCING INSPECTION ON THE FOLLOWING ITEMS: TOP OF LIGHT <br /> WORK. ANY DISCREPANCIES SHALL BE BROUGHT TO THE °. CONCRETE REINFORCING PLACEMENT SPECIFICATIONS FOR DETAILS N S1.1S1.1 POLE BASE B SECTION <br /> ATTENTION OF THE ENGINEER BEFORE PROCEEDING. b. REINFORCING COUPLING n n <br /> PAINT BASE YELLOW 51.1 51.1 SCALE: 1/2" = 1'-0" <br /> B. LIGHT POLES, ANCHOR BOLTS, NUTS AND BASE PLATES AT C. ALL SOIL GRADING, EXCAVATION, FILL, DRILLED SHAFTS PER NOTE 4.F <br /> EACH LOCATION SHALL BE DESIGNED AND SUPPLIED BY THE AND FINAL FOUNDATION PREPARATION SHALL BE <br /> POLE MANUFACTURER. CONTRACTOR SHALL COORDINATE SHOP INSPECTED BY THE PROJECT GEOTECHNICAL ENGINEER. <br /> DRAWINGS TO VERIFY COMPATIBILITY AND BRING ANY FOR POLE BASE B <br /> DISCREPANCIES TO THE ATTENTION OF THE ENGINEER D. ALL INSPECTION SHALL CONFORM TO THE REQUIREMENTS REINF SEE <br /> OF THE IBC. S1.1 S1.1 Y © 3'-0" DIAMETER <br /> C. CONTRACTOR SHALL REFER TO ELECTRICAL DRAWINGS FOR TOP OF <br /> SIZE AND LOCATION OF OPENINGS AND DETAILS NOT SHOWN <br /> 9. DRILLED SHAFT FOUNDATION: PAVEMENT <br /> ON DRAWINGS. A. CAGE RING TEMPLATE SHALL BE DESIGNED AND tt <br /> o 0 0 0 <br /> D. CONTRACTOR SHALL COORDINATE WITH POLE MANUFACTURER SUPPLIED BY THE POLE MANUFACTURER. \\\\ <br /> FOR ALL REQUIREMENTS OF BASE PLATE AND ANCHOR BOLTS B. ADJUSTMENTS MAY BE MADE IN SPACING OF SHEAR 1 L\//\\°o000°o°o o 0°0°00 <br /> FOR EACH POLE AND VERIFY THAT THE ULTIMATE POLE REINFORCEMENT WHERE THERE IS CONFLICT WITH MIDDLE CUT OFF \\//\° ° 000 \/\ <br /> REACTIONS ARE LESS THEN OR EQUAL TO THOSE SHOWN IN CAGE RING SPACING AS APPROVED BY THE ENGINEER. <br /> NOTE 2. ELEVATION ° a <br /> SEE SCHEDULE <br /> C. THE ENDS OF SHEAR REINFORCEMENT SHALL BE <br /> E. CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY ANCHORED ACCORDING TO ACI 318. o <br /> PRECAUTION, ERECTION STABILITY AND TEMPORARY SHORING ~ > 3 <br /> 3" MIN BASE - a Tis <br /> � <br /> AS NECESSARY UNTIL PERMANENT SUPPORT AND STIFFENING FOR PAVING, BACKFILL AND COURSE #4 TIES SEE /R <br /> ARE SHALL w= <br /> BUILDINGS LAND EQUIPMENT OF FROM PROTECT <br /> DURING <br /> DRILLED SHAFT SCHEDULE COMPACTION REQUIREMENTS © > <br /> o CST- TUBE, TYP. <br /> AROUND POLE BASE SEE � = m_ <br /> SHAFT DRILLING. SPECIFICATIONS ¢ SEE SPECIFICATIONS <br /> MIN TIP TOP OF SHAFT MIN PENETRATION <br /> LIGHT �> (11) #8 VERT BARS FOR MATERIAL AND <br /> ELEVATION CUT OFF INTO BEARING a m INSTALLATION <br /> F. ALL EXPOSED CONCRETE SURFACES SHALL BE PAINTED POLE (FT) ELEVATION (FT) LAYER (FT) EVENLY SPACED <br /> SAFETY YELLOW. ¢ REQUIREMENTS <br /> s <br /> 5. DRILLED SHAFT, BASE, AND SPREAD FOOTING MATERIAL: LP-1 -29.89 15.11 45 o z <br /> CONCRETE STRENGTH AT 28 DAYS (f'c) SHALL BE 5000 PSI. CSECTION <br /> LP-2 -29.89 15.11 45 C <br /> THE REINFORCING STEEL SHALL BE GRADE 60 (fy=60,000 PSI) LP-3 -29.89 15.11 45 S1.1S1.1 a 51.1 51.1 SCALE: 1/2" = 1'-0" <br /> CONFORMING TO ASTM A-615. THE MINIMUM CONCRETE COVER s <br /> IS 3 INCHES UNLESS OTHERWISE INDICATED. REFER TO PROJECT LP-4 -29.47 1553 41 NOTE <br /> SPECIFICATIONS. <br /> LP-5 -31.04 13.96 45 <br /> 1. MINIMUM TIP ELEVATION SHALL BE PER THE <br /> 6. NON-SHRINK GROUT- LP-6 -29.04 15.96 45 n DRILLED SHAFT SCHEDULE SHOWN ON THIS <br /> GROUT SHALL BE NON-SHRINK NON-METALLIC CEMENTITIOUS LP-7 -29.04 15.96 45 SHEET AND THE PROJECT SPECIFICATIONS. CALL48HOURS <br /> GROUT CONTAINING NATURAL AGGREGATES DELIVERED TO JOB <br /> SITE IN FACTORY PREPACKAGED CONTAINERS REQUIRING ONLY LP-8 -34.04 15.96 46 3'-0"b DRILLED SHAFT a ACTUAL DEPTH BE DETERMINED BY <br /> GEOTECHNICALGINEER IN FIELD DURING BEFORE YOU DIG <br /> THE ADDITION OF WATER. MINIMUM 28 DAY COMPRESSIVE LP-9 -29.63 15.38 37 INSTALLATION. <br /> ENGINEER <br /> CONTRACTOR SHALL USE <br /> STRENGTH SHALL BE 10,000 PSI OR PER THE LIGHT POLE LP-10 -29.28 15.72 27 TEMPORARY CASING FOR ALL SHAFT DIAL811 .10 <br /> MANUFACTURER'S REQUIREMENTS, WHICHEVER IS GREATER. INSTALLATIONS. SEE NOTE 7.C. <br /> GROUT SHALL BE MIXED, APPLIED AND CURED STRICTLY IN LP-11 -27.07 17.93 45 TIP ELEVATION VERT DATUM: NAVD 88 <br /> ACCORDANCE WITH THE MANUFACTURER'S PRINTED <br /> INSTRUCTIONS. LP-12 -27.07 17.93 45 SEE SCHEDULE 2. EXISTING CONCRETE AND H-PILE FOUNDATIONS CONV TO MLLW = NAVD88+2.0 5 <br /> ;13 n 1 LP-13 1 -27.12 1 17.88 1 32 MAY BE ENCOUNTERED DURING SHAFT HORZ DATUM: NAD 83/91 <br /> �•c LP-14 -33.1 6 16.84 35 A SECT 0 0 N PRIOR TO INSTALLATION <br /> OHAFT AND <br /> NSTALLA NEED <br /> ONTOSEBEE PROJREMOVED W <br /> / SPECIFICATIONS FOR DETAILS. IF SHEET IS LESS THAN 22x34 <br /> m m S1.1 S1.1 SCALE: 1 2" = 1'-0" <br /> a REDUCE SCALE ACCORDINGLY > <br /> mLU <br /> 0 PROJECT ENGINEER: SCALE: <br /> Porto,f �� BEq� N. WATSON B CHECKED B AS SHOWN PORT OF EVERETT DWG. N0 S1 .1 <br /> DRAWN <br /> � Q9M1dor rlyej�� DESIGNEDDBY:BY: DATE: <br /> g�' '& K. PROUGH 0QED2021 NORTON TERMINAL DEVELOPMENT CIE NO. H <br /> & MTCA 3RD INTERIM ACTION 1-8-900-05 V <br /> EURETT 16015th Avenue,Suite 1300 <br /> T. LEMONS S. STORY PROJECT <br /> No P.O. BOX 538 Seattle,Washington 98101 �l87T`�`�+� STRUCTURAL NOTES & HIGH-MAST NO. MT-NT-2021-02.2 GC <br /> N EVERETT, WA 98206 ® O5/07/2021 NW FOR CITY REVIEW �b�pl�b D}1 Z` APPROVED BY: O <br /> N (425) 259-3164 PROJECT NO.01600120z06)382-0500 NO. DATE BY REVISION NO. DATE BY REVISION D5) 1 LIGHT POLE F D N DETAILS SHEET NO. 99 OF 149 1 LL <br />