Laserfiche WebLink
�Traile7rl WA ROOF: <br /> FASTENING SCHEDULE MATERIAL LIST <br /> LLS: <br /> PLATE-TO-STUD MIN. OF 2- 0.121" x 3" NAILS ROOFING,............30 GA. GALV. WITH J-RAIL <br /> BOND ROOF TO STEEL TRANSPORTING FRAME <br /> PANEUNG-TO-STUD .030 THICK x %4 STAPLES AT 6" EDGE, 12" IN FIELD (SENCO K-11 OR EQUAL) WITH TWO- 30 GA, x 4" STEEL STRAPS <br /> SHEATHING-TO-FLOOR 0.131" x 3" NAILS AT 8" cc. (SENCO KC27 OR EQUAL) ONE AT EACH ENDWALL OPPOSITE CORNERS. <br /> LP SMARTSIDE-TO-STUD ®SIDEWALL 0.099 x 2" GALV NAILS AT 6" EDGE, 12" IN FIELD. SHEATHING...........3fs" APA RATED (24/16) <br /> FASTEN SHEATHING under FASCIA TO ALL TRUSS FRAMING (AND AT 4" o.c. TO TOP AND BOTTOM), ALL EDGES SUPPORTED FRAMING.............137' BOW TRUSS AT 24" or. <br /> w/16 GA. x 1 1/2" STAPLES(N-17) ®4" cc. LP SMARTSIDE-TO-STUD ®ENDWALL SEE ENDWALL FASTENING NOTES ON PAGE A-3. <br /> THREE STUD CORNER CONNECTION 0.131" x 3" NAILS AT 8" (SENCO KC27) RIMS.................2 x 10 D.F. #2 WITH <br /> W x 1Y2" x 19" VENT BLOCKS ABOVE AND <br /> SHEATHING 1Y2" x 1h' X CONTINUOUS LUMBER BELOW <br /> FLOOR JOIST-TO-RIM MIN. OF 4- 0.131" x 3" NAILS (SENCO KC27 OR EQUAL) INSULATION..........R-30 CELLULOSE BLOW-IN <br /> FASCIA CLASS "A" BOTTOM COVER-TO-JOIST 16 GA. x %" WIDE CROWN STAPLES AT 12' MAX. EDGES ONLY CEILING..............SUSPENDED T-BAR (PER IBC SEC. 803.9.1.1 <br /> 2x4 BLOCKING FLOOR DECKING-TO-2x JOIST 0.113" x 2%" RING SHANK NAILS (SENCO GE-24 OR EQUAL). & 1621.2.5) <br /> USE CONSTRUCTION ADHESIVE (AFG01) ON JOISTS AS FOLLOWS: VENTING.............EAVES <br /> ALL INTERIOR JOISTS AT 6" EDGE, 12" FIELD. <br /> WALLS: <br /> END TRUSS <br /> ROOF" SIDING...............7is" LP SMARTSIDE WITH GROOVES AT B"oc <br /> ENDWALL SIDING FASCIA,..............%" N.G. DURATEMP <br /> RIM—TO—TRUSSES MIN. 5— 0.131' x 3' NAILS (SENCO KC27 OR EQUAL) <br /> 3/8" OSB TRUSS—TO—TOP PLATE AT ENDWALL 0.131" x 3" NAILS ®6' cc. (SENCO KC27 OR EQUAL) TRIM..................1 x 4 PRIME TRIM AT CORNERS & WINDOWS <br /> BOTTOM ROOF RIM-TO-TOP PLATE 0.131" x 3" NAILS ®8" cc. (SENCO KC27 OR EQUAL) FRAMING.........EXT.,2 x 4 H.F. 'STANDARD" or "STUD" <br /> or BETTER STUDS AT 16"oc <br /> END TRUSS DETAIL SHEATHING-TO-ROOF MEMBERS 1. USE �IIe" APA RATED SHEATHING INSTALLED WITH SEAMS OFFSET 4'-0". EXCEPT*.2 X 6 END WALL <br /> 2. USE CONTINUOUS 2 x 4 MICROLLAM TOP PLATE FOR DIAPHRAGM CHORD. NT:2 X 4 H.F. 1 or. <br /> EXCEPT:2 X 8 & PLUBING WALLS <br /> 3. USE 2 x 3 or 2 x 4 TIGHT FIT BLOCKING AT ALL UNSUPPORTED TOP PLATE..........2 x 4 CONTINUOUS MICROLLAM (LVL 2.OE) <br /> EDGES FOR DISTANCE OF 10'-0" FROM EACH END. <br /> BOTTOM PLATE......2 x 4 H.F. <br /> 4. STAPLE ROOF SHEATHING WITH 16 GA. x 1%7 STAPLES (N-15) <br /> AT 6" EDGE, 12" IN FIELD, 4' o.c. AT VENTED EAVES. INSULATION...........R-13 FIBERGLASS BATT. <br /> INTERIOR FINISH......Y." PANELING AND P.L WAINSCOT PER CODE <br /> STRUCT. SHEATHING..%" A.P.A. RATED SHEATHING UNDER PANELING <br /> LU26 HANGERS AT ALL TRUSSES ABOVE AT END WALLS ONLY <br /> n SIDEWALL OPENINGS w/6- 10d x 1X2" n BELT RAIL............5" X 7/15" NO GROOVE LP SMARTSIDE <br /> Y NAILS TO 2 x 10 ROOF RIM <br /> FLOOR: <br /> COVERING............76" VCT <br /> CAULK AT NOTE:LAY VCT IN "ASHLAR" PATTERN <br /> ROOF RIM/ IN' x W x 19" VENT BLOCK <br /> TOP PLATE CENTERED AT EACH TRUSS AND DECKING.............�7iz" A.P.A. RATED STURD-I-FLOOR <br /> STAPLE TO 2 x 10 ROOF RIM WITH FRAMING.............2 x 8 DF #2 FLOOR JOISTS AT 16"oc <br /> 5- 15 GA. x 2Y2" STAPLES OR <br /> 4- 14 GA. x 3Ys" STAPLES. RIMS.................2 x 8 MICROLLAM CONTINUOUS (LVL 2.OE) <br /> COVER GAP WITH Yi GALV. MESH <br /> PROVIDE CONTINUOUS BRACING INSULATION..........R-25 FIBERGLASS BATT <br /> AT TRUSS BOTTOM CHORD 2 x 4 x D VENT BLOCK <br /> (CENTERED AT EACH TRUSS) <br /> MAY BE LOCATED ANYWHERE BOTTOM COVER......CLASS "A" <br /> I %" x 7Ya" N.G. <br /> THE MIDDLE BAY) DURATEMP FASCIA FRAME <br /> Y <br /> LF— U <br /> 2x10 OF #2 RIM (SPLICE BETWEEN TYPE................TRANSVERSE <br /> CAULK w Jm TRUSSES USING 2x10 BACKER) <br /> AROUND w = MAIN RAIL...........10' JR. I-BEAM <br /> WINDOWS = _j ONE DRY CUP PERM o GALV. SIDING NAILS ®4" cc. USE 11 GA FULL HEIGHT CROSSMEMBERS <br /> 0 a VAPOR BARRIER ON x 1Y2" x 1Y2" CONT. LUMBER AT FRONT& REAR <br /> Z 3 THE WARM SIDE STAPLED TO 2 x 10 RIM WITH <br /> : TYPICAL THRU-OUT. ? 15 GA, x 2Y2" STAPLES AT 8' ox. AXLES...............3-BRAKE, 8:00 14.5 14-PLY TIRES <br /> w WITH ROCKERS <br /> m U J <br /> ti„ a, CAULK ALL CORNERS <br /> to o FROM TOP TO 80TTOM - EAVE DETAIL HITCH................DETACHABLE <br /> I o - 1-� FASTENING REQUIREMENTS: <br /> I FLOOR JOIST TO I-BEAM.....916" x 3" LAGS AT 32" o.c. <br /> m (ALTERNATE SIDE TO SIDE OF EACH I-BEAM) <br /> END CROSSMEMBER CONNECTION TO END RIM JOIST.... <br /> (7) Ns" x 3" LAGS <br /> CAULK AT <br /> FLOOR RIM/ SIDING <br /> IDING <br /> PLATE <br /> "Z" FLASHING <br /> 991" � FLOOR JOIST r7 <br /> 11'-8" 5" X 7//16" NO GROOVE <br /> LP SMARTSIDE PANEL <br /> /� <br /> BELT RAIL <br /> SECTION — A A BELT RAIL DETAIL <br /> 1/2" = 1'-D" <br /> '�..U5T=-n SOP 5 %"'v'/,jLL'?r`�E7,ENG Phi cV' COPYRIGHT 2006,BLAZER INDUSTRIES,INC. ■ MOBILE ` Approved for Const: hb No: 14200-04 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY <br /> OF BLAZER INDUSTRIES.INC.AND SHALL ■■ File Copy: <br /> NOT BE REPRODUCED,USED.OR DISCLOSED 12 X 56 Lease Unit <br /> A=2 <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE '��"-""F"'-"�� Drawn By: /1GY <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. ■■ P.O, Box L89�AUM$VILLE,oa 97325-^uLa9 OR, WA, ID PACIFIC MOBILE 05 BLMP-22 A2 Star.Dale: 1-240! <br />