Laserfiche WebLink
1"PER PLAN <br /> " <br /> BRANCH LINE- 1 ELBOW WET SYSTEM NO. 1 <br /> 20 GAUGE METAL DECK AREA AREA NUMBER OF <br /> + + � DESCRIPTION SO.FOOTAGE SPRINKLERS <br /> 1/4"x 1 5/e"HILTI KH- 1"F.Q.- LEVEL 1 WET 24,731 144 <br /> J4g° SAMMY XP20 <br /> SCREW ANCHOR Z 'H/N EXPRESS SCREW <br /> (3/8"ATR THREADS) <br /> 1p TOLCO FIG.75 SWIVEL <br /> TOLCO FIG.75 SWIVEL <br /> 3/8'ATR W/ SURGE ATR W/ <br /> SURGE CLIP <br /> SURGE CLIP HANGER RING HANGER RING HYDRAULIC CALCULATION DATA <br /> 1"ELBOW <br /> 72"EASY FLEX ACTUAL DENSITY: .10 GPM / 1053.68 SQUARE FEET <br /> ND AT BASE 0 <br /> L1 - L3 L4 <br /> 3304.8 GPM AT 56.16 RISER <br /> ( 0 GPM INSIDE HOSE ALLOWANCE) <br /> DEMAND AT CITY CONNECTION <br /> 554.8 GPM AT 66.8 PSI ( 250 GPM TOTAL HOSE ALLOWANCE) <br /> BRANCH LINE RESTRAINT: CEILING <br /> -BRANCH LINE RESTRAINT REQUIRED AT END HEAD OF BRANCH LINES WITHIN 6"OF END <br /> HANGER THAT IS INSTALLED TO UMIT UPWARD MOVEMENT. SSP / SYSTEM N O. 2 <br /> -RESTRAINT WILL NOT BE REQUIRED WHERE BRANCH LINES ARE SUPPORTED BY RODS <br /> LESS THAN S'LONG. AREA AREA NUMBER OF <br /> -SPACING OF BRANCH LINE RESTRAINT WILL BE AS FOLLOWS: DESCRIPTION SQ.FOOTAGE SPRINKLERS <br /> 1 - 36FEET FLEX DROP <br /> 1 1/4 39 FEET LEVEL 2 WET 17,684 167 <br /> 1 112 - 41 FEET <br /> 2 45 FEET <br /> HYDRAULIC CALCULATION DATA <br /> 1"TEE W/PLUG 1"(04.5)U.N.O. <br /> ACTUAL DENSITY: .10 GPM / 1001.25 SQUARE FEET <br /> DEMAND AT BASE OF RISER <br /> -BRANCH LINE 173.8 GPM AT 30.7 PSI ( 0 GPM INSIDE HOSE ALLOWANCE) <br /> [CEILING DEMAND AT CITY CONNECTION <br /> 273.8 GPM AT 45.5 PSI ( 100 GPM TOTAL HOSE ALLOWANCE) <br /> WALL E 2"PER PLAN 5'-0" <br /> y AFF v <br /> GWB CEILING 1"THIRD.TEE/PLUG <br /> (WHERE OCCURS) ^2"SCH 40(04)TXG <br /> SYSTEM NO. 3 <br /> \ 2"BALL VALVE 6.p <br /> L `DRY HORIZONTAL AFF TYCODD-1 AREA AREA NUMBER OF <br /> L0,_3. SIDE WALL SPRINKLER2"(0-3)SCH 40 NIPPLE DRUM DRIP DESCRIPTION SQ.FOOTAGE SPRINKLERS <br /> F3QR DRY PENDENT 2"45°ELL WITH- L3 WET SYSTEM 18,639 176 <br /> A=F.O. 5.6K SMOOTH BORE BUSHING <br /> MIN. <br /> DRY PENDENT DRY SIDEWALL INSPECTORS TEST LOW POINT DRAIN HYDRAULIC CALCULATION DATA <br /> ACTUAL DENSITY: .15 GPM / 945 SQUARE FEET <br /> DEMAND AT BASE OF RISER <br /> 206.3 GPM AT 48.6 PSI ( 0 GPM INSIDE HOSE ALLOWANCE) <br /> DEMAND AT CITY CONNECTION <br /> 456.3 GPM AT 71.8 PSI ( 250 GPM TOTAL HOSE ALLOWANCE) <br /> MIN.1 1/4" CONCRETE PAN DECK STEEL I BEAM <br /> 1 (MIN.18 GA.) 20 GAUGE METAL DECK <br /> $$ T SAMMY XP20�e 3/8"ANVIL 92 SYSTEM NO. 4 <br /> -� mffi I EXPRESS SCREW 55 _�TOP BEAM CLAMP <br /> T 3//I 8"(0-3)ATR 1/4"x 1 5/8"HILTI KH-EZ ? 3/8"(0-3)ATR AREA AREA NUMBER OF <br /> °w SCREW ANCHOR CZ <br /> DESCRIPTION SQ.FOOTAGE SPRINKLERS <br /> m 10"RETAINER STRA L4 WET SYSTEM 17,067 169 <br /> (3/8"AT THREADS) m 3/8'ATR CTS, (03)ATR <br /> 3/8'ATR CTS- \y\ 3"..ROD COUPLING 3/8"ROD COUPLING <br /> 3/8"ATR CTS <br /> HANGER RING <br /> 3/8"ROD COUPLING 15 <br /> HANGER RING ,.-2.5. HYDRAULIC CALCULATION DATA <br /> HANGER RING ACTUAL DENSITY: .10 GPM / 974.03 SQUARE FEET <br /> DEMAND AT BASE OF RISER <br /> 169.5 GPM AT 44.8 PSI ( 0 GPM INSIDE HOSE ALLOWANCE) <br /> HANGER EZ HANGER XP HANGER TB 2269.5ND GPMIA C070.7CPSI( 100 GPM TOTAL HOSE ALLOWANCE) <br /> n <br /> SYSTEM NO. 5 <br /> `WIDE FLANGE STEEL BEAM WIDE FLANGE STEEL BEAM AREA AREA NUMBER OF <br /> DESCRIPTION SO.FOOTAGE SPRINKLERS <br /> (3)3(2.3)GALV.TOE <br /> TOLCO FIG.828 BEAM CLAMP L2 DRY SYSTEM 17,684 43 <br /> GUARDIAN 64743 HOLE ROUGH BRASS <br /> WALL PLATE"AUTO SPKR&SP <br /> WEBBING OF RIGID FRAMING TOLCO FIG.828 BEAM CLAMP TOLCO FIG.828 BEAM CLAMP _ <br /> ® ® TOLCO FIG.980 SWIVEL END TOLCO FIG.980 SWIVEL END ^ <br /> (3)2.5"GUARDIAN 6418 <br /> (2)TOLCO FIG.980 45° 45° (2)1/2'x11/2"BOLT W/ 45°-59° 45°-59° CLAPPER SNOOT HYDRAULIC CALCULATION DATA <br /> NUT&WASHER FROM VERTICAL FROM VERTICAL <br /> SWIVELEND <br /> (2)1"x(3-6)SCH 40 BRACE PIPE ACTUAL DENSITY: .15 GPM / 1950 SQUARE FEET <br /> DEMAND AT BASE OF RISER <br /> (2)TOLCO FIG 1001 1"(3-6)SCH 40 BRACE PIPE 1"(2-6)SCH 40 BRACE PIPE ® - 2 a 327.6 GPM AT 61.2 PSI ( 0 GPM INSIDE HOSE ALLOWANCE) <br /> FAST CLAMP (2)1"MIN EXCESS PIPE DEMAND AT CITY CONNECTION <br /> THROUGH FAST CLAMP TOLCO FIG.1001 BRACE CLAMP LEVEL 1 0-3 <br /> ALL DR I 577.6 GPM AT 71.6 PSI ( 250 GPM TOTAL HOSE ALLOWANCE) <br /> 1"MIN.EXCESS PIPE THROUGH CLAMP / <br /> TOLCO FIG.4LJ DRY SYSTEM CAPACITY: 225 GALLONS <br /> PIPE CLAMP <br /> EQ 1 EQ 2 EQ 3 FDC DETAIL <br /> 0 2 4 <br /> SCALE 1/2"=1'-O" <br /> FACING SOUTH <br /> CLASS I MANUAL WET STANDPIPE <br /> HYDRAULIC CALCULATION DATA <br /> ACTUAL DEMAND: 500 GPM @ 100 PSI <br /> PLUS 250 GPM FOR ADDITIONAL STANDPIPES <br /> (UP TO A MAXIMUM OF 1000 GPM) <br /> DEMAND AT FDC CONNECTION <br /> 750.0 GPM AT 143.1 PSI <br /> DETAILS <br /> HANGER LEGEND SPRINKLER LEGEND ABBREVIATIONS SYMBOL LEGEND REVISIONS CONTRACT WITH SMITH FIRE SYSTEMS, INC. <br /> SYM MANUFACTURER S.I.N. TYPE MODEL sEriN""Is i" �`��"EON °;'g`£ T1PFA° i°"" O1"'""Y AFF ABOVE FINISHED FLOOR NO. DATE BY REASON FOR REVISION <br /> EN�s, s'g "'TH° Bae BOTTOM OF BEAM 12 CENTERLINE OF PIPE TO REFERENCEDIF IF <br /> STRUCTURE IN INCHES BNBUILDERS 1106 54th AVE EAST <br /> BOD BOTTOM OF DECK BOD TACOMA,WA 98424 <br /> SOU BOTTOM OF JOIST <br /> BOP BOTTOM OF PURUN 2-WAY EARTHQUAKE SWAY BRACE 2601 FOURTH AVE r""wnsN xorory s;ATe..... CONTR.REG.NO.SMITHF81360T <br /> BOT BOTTOM OF TRUSS YHOTECOTIOH eYBIHKLEH 6T6T <br /> CTS cur To surt LETTER INDICATES TYPE 1 FIBe s 1 Bus: (253)926-1880 FAX: (253)926-2350 <br /> Fo FIELD ORDER 4.WAY EARTHQUAKE SWAY BRACE SUITE 350 1 1 <br /> IFOW INSIDE FACE OF WALL . SEATTLE,WA 98121 1 Aaron Stewart Nelson 1 <br /> NM OUTSIDE FACE OF WALL LETTER INDICATES TYPE <br /> NM NO AUTO.SPRINKLERS 1 Smith lFre�stems inc. � 1 <br /> SY COMPASS HEALTH <br /> ueo uNLEss NOTED OTHERWISE f HANGER LOCATION PROJECT MANAGER:ADAM SMITH 1 S/M�ITHFS73�60'T� 31 PHASE 11 <br /> 1-��� '1 <br /> ELEVATION ABOVE REFERENCED PHONE:(206)491-6592 1 B.Pl.e.l <br /> POINT IN FEET AND INCHES 1 zl 3322 BROADWAY <br /> FAX: �s4^��------------J <br /> O HYDRAULIC CALCULATION NODE SUPERINTENDENT: EVERETT,WA 98201 <br /> M FLEXIBLE COUPLING PHONE <br /> FAX: DESIGNER PROJECT MGR DATE SHEET JOB NO. <br /> TOTAL THIS SHEET !I- RIGID COUPLING CERTIFICATE OF COMPETENCY STAMP KEY PLAN ERIC S. NICKG. 1 6/20/24 1 2 OF 8 NC24103 <br />