Laserfiche WebLink
convergjnt' <br /> converg 'hit 450 Shattuck Avenue South,Renton,Washington 98057 <br /> Phone:425-272-2250 Fax:425-251-0949 <br /> This document and the info,maton/depicb,ns mnWinedlshown <br /> is the exclusive property of COn-mint Technologies LLC and shall <br /> be handled as propnetary and wnfld.nti.1 information and must be <br /> retuned upon request.This dowmenl cannot be repradumd by any <br /> rneons without the wrltlen euthodutlon of Convergint Technologies LLC. <br /> COMPASS HEALTH EVERETT Permit# 332 <br /> Site Address: 33222 Broadway <br /> Broadway <br /> Applicant: Cadssa Thomson <br /> FIRE ALARM Application Date:05/O6/2024 <br /> Description: Compass Health-Fire Alarm System <br /> -New Construction <br /> Review Date: 05/08/2024 <br /> 3322 BROADWAY, EVERETT, WA, 98201TW <br /> EVERETT Ev <br /> Everett Fire Permit Review <br /> Dept. <br /> Status:Approved <br /> Reviewed By:KBrown <br /> 05/08/2024 3:21:37 <br /> PM <br /> SYMBOL LEGEND SCOPE OF WORK WIRE LEGEND MOUNTING HEIGHTS - <br /> Everett Fire Dept.Notes A <br /> SYM DESCRIPTION MODEL# MANUFACTURER BACK BOX THIS SCOPE OF WORK INCLUDES: ALL WIRING AND INSTALLATION METHODS SHALL BE IN COMPLIANCE WITH CURRENT RELEVANT (NFPA 72) <br /> NEW EST4 ANALOG ADDRESSABLE FIRE ALARM SYSTEM WITH VOICE NOTIFICATION.RATH 2-WAY NATIONAL AND LOCAL ELECTRICAL CODE ARTICLES AND RELATED SECTION CODE REQUIREMENTS. I f EVERETT <br /> INCLUDED-SEE PANEL DETAILS FOR COMMUNICATIONS SYSTEM.REMOTE ANNUNCIATOR LOCATED IN VESTIBULE C101.DETECTION AND NC SUPPLY DIFFUSER <br /> FACPxK FIRE ALARM CONTROL PANEL EST-4 EST DIMENSIONS NOTIFICATION PROVIDED TO MEET CODE.LEVELS 3 AND 4 WILL BE PRIVATE MODE FOR ROOM WIRING INSTALLATION NOTES: CEILING MOUNTED See Attached Fire Alarm System r <br /> $MOKEIHEAT FLUORESCENT LIGHT I Acceptance Test Checklist. <br /> N TIFI ATI ON WILL ANNUNCIATE AT THE R M AND AT THE NURSES TATI N.LEVEL 4 P O C O00 STATION. S 3& LABEL ALL ZONE WIRES WITH ZONE NUMBER TAG AND DESCRIPTION. <br /> NACxx NAC POWER SUPPLY-5A EBPSGA EST INCLUDED-17"H X 13"W X 3.5"D WILL ALSO BE PARTIAL RELOCATION WITH AN EVAC SIGNAL IN THE COMPARTMENT OF ALARM AND 'LABEL ALL SIGNAL CIRCUIT WIRES WITH SIGNAL CIRCUIT NUMBER TAG AND DESCRIPTION. DETECTOR TYP. T(MIN) <br /> e AN ALERT SIGNAL IN THE ADJACENT COMPARTMENT. 'LABEL ALL NETWORK,ANNUNCIATOR AND 1/0 CONTROL CIRCUIT WIRING WITH CIRCUIT NUMBER No <br /> DMENsloes SHOWN I-24 hour Battery Test-At the time of the <br /> ARE TO THE CLOSEST <br /> ATcxx FIRE ALARM TERMINAL CABINET BYOTHERS BY OTHERS - TAG AND DESCRIPTION. CEILING EDGE OF THE DETECTOR inspection/test provide proof verifying that the i <br /> DESIGN CRITERIA APPLICABLE STANDARDS AND GUIDANCE: •VERIFY WITH OWNER AND GENERAL CONTRACTOR THAT OPEN CABLE IS ALLOWED ON SPECIFIC I panel has been operating on Secondary power <br /> UNIVERSAL INPUT/OUTPUT MODULE 2018 WASHINGTON STATE BUILDING CODE SITE.(FPL,FPLP,RISER,OR 2 HOUR RATED) (battery) <br /> batte for 24 hours.No other problems i <br /> ulo::s U10 EST MOUNTED IN TERMINAL CABINET ( �') <br /> R MOTHERBOARD 2018 WASHINGTON STATE FIRE CODE 'WHERE REQUIRED,OUR DRAWINGS WILL NOTE WIRE OR PATHWAY REQUIRING SURVIVABILITY. I shall be for <br /> on the panel. <br /> 2018 WASHINGTON STATE MECHANICAL CODE SUBSTITUTE THE RELEVANT CABLE WITH AN EQUIVALENT CABLE COMPATIBLE WITH THE MEANS OF 3' <br /> -elss CEILING <br /> -WP RATE COMP HEAT 135° AUDIONISUAL&VISUAL 12" i <br /> 302-ET-135 EST 4"OCTAGON BOX,1-1/2"DEEP SURVIVABILITY.THIS OFTEN INCLUDES;RO OR Cl CABLE(CIRCUIT INTEGRITY),CONCRETE I-Record of Completion-For all new <br /> CEILING MOUNT ONLY DEVICES MAX <br /> 5623-FIXED HEAT 135° OCCUPANCY/USE CLASSIFICATIONS: N ORMATION ENCASEMENT OR OTHER MEANS AS APPROVED BY THE AHJ.REFER TO NFPA 72 FOR FURTHER b' <br /> H 5623 EST 4"OCTAGON BOX,1-1/2"DEEP systems, r Record of Completion is required <br /> CEILING MOUNT B-BUSINESS FIRE ALARM REMOTE MANUAL PULL to be entered into The Compliance Engine I <br /> S-2-STORAGE NON PLENUM: SINGLE COND.: PLENUM RATED: FIREALARM ANNUNCIATOR STATION prior to permit final. <br /> F DOUBLE ACTION PULL STATION SIGA-278 EST SINGLE GANG,2-1/2"DEEP CIRCUIT DESCRIPTION <br /> STANDARD I-1-CONDITION 2 (FPLR,FPL) (THHN,TFFN) (FPLP) CONTROL PANEL I(www.thecomplianceengine.com) I <br /> O SINGLE INPUT RISER MODULE SIGA-CC1S EST 4"SQUARE BOX,1-1/2"DEEP,DOUBLE GANG DOCUMENTATION AVAILABLE TO CONVERGINT TECHNOLOGIES A ZONE/INPUT CIRCUIT BELDEN 5220UL (2)#16 AWG BELDEN 6220UL J __________________J <br /> WITH SYNC OUTPUT COVER 80"MIN.TO BOTTOM Tp� <br /> 780-CHP2-20230501-ASI-02-SET 2 COND.16 AWG [3.850][24pF/FT] [3.850][37pF/F7] OF LENS Q <br /> 4"SQUARE BOX,1-1/2"DEEP,SINGLE GANG 780-CHP2-20230501-ASI-02-SPECIFICATIONS <br /> Q CONTROL RELAY MODULE SIGA-CR EST C NAC CIRCUIT BELDEN 5120UL (2)#14 AWG BELDEN 612OUL OR �+ <br /> COVER HVAC Ducting 780-CHP2-20230501-ASI-02-SET 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] 96"MAX.TO TOP <br /> O CONTROL RELAY MODULE SIGA-CRH EST 4"SQUARE BOX,1-1/2"DEEP,DOUBLE GANG OF LENS 72"AFF ® r=jJ <br /> HIGH VOLTAGE COVER D MASS.NOTIFICATION NAC CIRCUIT BELDEN 5120UL (2)#14 AWG BELDEN 612OUL 60"AFF z <br /> 2 COND.14 AWG [2.43Q][23pF/FT] [2.430][37pF/FT] 48"MAX(ADA) _ <br /> Q SINGLE INPUT MODULE SIGA-CT1 EST 4"SQUARE BOX,1-1/2"DEEP,SINGLE GANG 42"MIN/54"MAX(NFPA) <br /> COVER E DOOR HOLDER/CONTROL CIRCUIT BELDEN5120UL (2)#14AWG BELDEN 6120UL <br /> 4"SQUARE BOX,1-1/2"DEEP,SINGLE GANG CONTACT INFORMATION 2COND.14 AWG [2.430][23pF/FT] [2.430][37pF/F7] <br /> Q DUAL INPUT MODULE SIGA-CT2 EST COVER F FAN/HVAC SHUTDOWN BELDEN 5120UL (2)#14 AWG BELDEN 6120UL FINISHED FLOOR <br /> Q ISOLATOR MODULE SIGA-IM2 EST 4"SQUARE BOX,1-1/2"DEEP,DOUBLE GANG PROJECT MANAGER FIRE ALARM DESIGNER 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] "DEVICES SHOWN DEPICT DEVICE TYPES ONLY. <br /> COVER CARISSA THOMSON HARLAN KIND <br /> 4"SQUARE BOX,1-1/2"DEEP,SINGLE GANG 425-757-3295 512-632-0219 G FUTURE ADA NAC BELDEN 5120UL (2)#14 AWG BELDEN 612OUL <br /> XR REMOTE ALARM LED-CEILING SIGA-LED EST COVER CARISSA.THOMSON@CONVERGINT.COM HARLAN.KIND@CONVERGINT.COM CIRCUIT 2 COND.14 AWG [2.43Q][23pF/FT] [2.430][37pF/FT] <br /> H PHONE CIRCUIT BELDEN 5220FL N/A BELDEN 6220FL '1 <br /> STANDARD ADDRESSABLE SMOKE SALES REPRESENTATIVE x C <br /> 0 SIGA-SB4-STANDARD BASE SIGA-OSD EST 4"OCTAGON BOX,1-1/2"DEEP KEVIN CURREY 2 COND.16 AWG SHIELDED [3.90][65.5pF/FT] [3.850][77pF/FT] m > g J 4 <br /> 206-941-4692 < +. <br /> ADDRESSABLE DUCT DETECTOR J SPEAKER CIRCUIT BELDEN 5220UL (2)#16 AWG BELDEN 6220UL <br /> (� SIGA-SD EST SELF-CONTAINED KEVIN.CURREY@CONVERGINT.COM <br /> 7Y TUBE SIZE:24"(MODEL#SD-T24) 2 COND.16 AWG [3.850][24pF/FTJ [3.850][37pF/FT] <br /> ADDRESSABLE DUCT DETECTOR L ELEVATOR CONTROL BELDEN 5120UL 32rnd$t <br /> TUBE SIZE:36"(MODEL#SD-T36) SIGA-SD EST SELF-CONTAINED (2)#14 AWG BELDEN 612OUL <br /> GENERAL NOTES AUDIO 14 AWG [2.430][23pF/FT] [2.4301[37pF/FTJ <br /> WEATHERPROOF SPEAKER/STROBE-CEILING R 7-7A- EST EST MODEL"757A-WBW" M AUDIO RISER BELDEN 5220FL N/A BELDEN 6220FL <br /> COLOR:WHITE,MARKING:FIRE,LENS:CLEAR RS70W 2 COND.16 AWG SHIELDED [3.90][65.5pF/FT] [3.850][77pF/FT] Y <br /> WEATHERPROOF SPEAKER STROBE-CEILING 7 <br /> COLOR:WHITE,MARKING:FIRE,LENS:CLEAR RS70W EST EST MODEL"757A-WBW N NETWORK COMMUNICATIONS BELDEN 1583A N/A BELDEN 1585A" THE FOLLOWING NOTES ARE INTENDED TO BE GENERAL IN NATURE AND ARE NOT SPECIFIC TO EACH e <br /> PROJECT.THESE NOTES ARE TO BE FOLLOWED WHERE APPLICABLE TO INDIVIDUAL PROJECTS AND CATS OR BETTER <br /> WEATHERPROOF STROBE-WALL MOUNT SHOULD NOT BE TAKEN AS SCOPE OR DIRECTION WHERE THEY CONFLICT WITH INFORMATION FOUND <br /> yyy COLOR:RED,MARKING:FIRE,LENS:CLEAR CS405-7A-T EST EST MODEL"449" ELSEWHERE IN THIS DRAWING SET. P 24VDC AUX.POWER BELDEN 5120UL (2)#14 AWG BELDEN 612OUL 33rd St i <br /> SPEAKER/STROBE-CEILING MOUNT GCSVWN EST 4"SQUARE W/EST MODEL"GRSW-10" 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] <br /> F+XrNal <br /> COLOR:WHITE,MARKING:NONE,LENS:CLEAR WIRING PLATE 1. ALL WIRE AND CONDUIT SHALL BE INSTALLED IN ACCORDANCE WITH PLANS AND p <br /> Q VESDA NET BELDEN 9841 N/A BELDEN 89841 <br /> C SPECIFICATIONS AND SHALL MEET ALL APPLICABLE CODES. a' F A SPEAKER-CEILING MOUNT GCSWN EST 4"SQUARE W/EST MODEL"GRSW-10" 2 COND.22 AWG [240][12.SpF/FT] [240][12pFIFTJ '+oxY N . <br /> COLOR:WHITE,MARKING:NONE WIRING PLATE 2. ALL WIRE AND CABLE SHALL BE RATED FOR FIRE ALARM USE PER THE LATEST REVISIONS OF D <br /> R REMOTE LED CIRCUIT BELDEN 5220UL (2)#16 AWG BELDEN 6220UL <br /> .0 STROBE-CEILING MOUNT 4"SQUARE W/EST MODEL"GRSW-10" THE NATIONAL ELECTRICAL CODE(NEC)SECTION 760.THIS IS A POWER LIMITED FIRE ALARM <br /> Cl.COLOR:WHITE,MARKING:NONE,LENS:CLEAR GCVWN EST WIRING PLATE SYSTEM.ALL CABLE MUST BE MARKED FPL,FPLP,FPLR OR CI FURTHER NEC,REQUIRES ALL 2 COND.16 AWG [3.850][24pF/FT] [3.850][37pF/FT] <br /> 7707PIRE BE RATED FOR THE ENVIRONMENT FOR WHICH IT IS INSTALLED.ANY REFERENCES TO S ADDRESSABLE DATA SLC LOOP BELDEN 5220UL (2)#16 AWG BELDEN 6220UL 3411.St <br /> FACAE MESH RADIO WITH CONTACT ID ULP-M AES INCLUDED-13"H X 8.5"W X 2.5'D WIRE DESIGNATIONS ASSUME ELECTRICAL CONTRACTOR WILL SUBSTITUTE APPROPRIATE 2 COND.16 AWG [3.85Q][24pF/FT] [3.85Q][37pF/FT] to <br /> WIRE TO MEET CODE. o <br /> s® MR101 EST INCLUDED-6.125"H X 3.25W X 2.5"D MULTI-VOLTAGE CONTROL RELAY N/A T1 ANALOG TWO-WAY COMM.CABLE N/A RATH RP66010001 a 3 <br /> C <br /> tut SINGLE POLE-DT 3. ALL CONDUCTORS SHALL TEST FREE OF GROUNDS AND SHORTS BEFORE MAKING ANY 2 COND.18 AWG [2-HOUR CIC] <br /> ® LOW AIR SWITCH BYOTHERS BYOTHERS - CONNECTION TO THE FIRE ALARM CONTROL PANEL. T2 ANALOG TWO-WAY COMM.CABLE RATH 66120 N/A WA D DESIGNER OF RECORD <br /> 4. TO RETAIN WARRANTY,THE FIRE ALARM EQUIPMENT MUST BE POWERED UP UNDER THE 2 COND.18 AWG [2-HOUR] r<P <br /> PI POST-INDICATING VALVE BYOTHERS BYOTHERS - SUPERVISION OF A QUALIFIED MANUFACTURERS TECHNICIAN. TP ANALOG TWO-WAY POWER CABLE N/A RATHR66010001 35t1St D TIVND <br /> 2 COND.18 AWG N/A [2-HOUR CIC] n FIRE ALARM SYSTEMS <br /> Ps PRESSURE SWITCH BYOTHERS BYOTHERS 5. THE INSTALLING ELECTRICAL CONTRACTOR SHALL COORDINATE ALL FIELD CHANGES WITH THE 2 n <br /> U SUPPRESSION RELEASING CIRCUIT BELDEN 5120UL 2#14 AWG BELDEN 6120UL :4 J"r <br /> FIRE ALARM CONTRACTOR.THIS INCLUDES CHANGES IN DEVICES,WIRE,CONDUIT RUNS AND () m D m .ERTIFIUTION we4ses <br /> OPERATION OF THE SYSTEM.FIRE ALARM CONTRACTOR SHALL NOT BE HELD RESPONSIBLE 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FTJ m < ExPIRE DATe.oenvzaza <br /> vs TAMPER SWITCH BYOTHERS BYOTHERS FOR UNDOCUMENTED CHANGES OR THE RESULTS OF THOSE CHANGES. A - FOR VERIFICATION,P-SE VISIT:W vNICET.ORG <br /> W SINGLE MODE FIBER NETWORK BUDGET SMXL02/SMXHI2:15/25 dBm D Q D q <br /> ,y <br /> WATER FLOW SWITCH BY OTHERS BY OTHERS - 6. FIRE ALARM NOTIFICATION DEVICES SHALL BE AUDIBLE THROUGHOUT THE SPACE AND SHALL 8.3p SM CONNECTOR:DUPLEX SC <br /> HAVE A SOUND PRESSURE LEVEL NOT LESS THAN 15db ABOVE THE AVERAGE AMBIENT SOUND X MULTIMODE FIBER NETWORK BUDGET MMXVR:10 dBm <br /> �s FIRE SMOKE DAMPER BYOTHERS BYOTHERS - LEVEL OR 5db ABOVE THE MAXIMUM SOUND LEVEL,MEASURED AT 5'0"ABOVE THE FINISHED 50/125p,62.5/125p OR 100/140p MM CONNECTOR:ST <br /> FLOOR. VICINITY MAP convergjnt" <br /> 2WAY SMARTRESCUE MASTER STATION Y TWO-WAY COMMUNICATIONS BELDEN 1583A IN BELDEN 1585A <br /> AxcM 2500-210B RATH INCLUDED-15.07"H X 12"W X 6"D 7. MAIN BUILDING FIRE ALARM&SUPPRESSION SYSTEMS SHALL BE CLASS"B"WIRING. CAT5E-(4)PAIR 22 AWG <br /> 5 ZONE,SURFACE MOUNT <br /> PRE-ACTION&DELUGE ALARM SYSTEMS SHALL BE CLASS"A"WIRING.CLASS"A"APPLICATIONS Z FIRE/SMOKE DAMPER INTERFACE BELDEN 5120UL 2#14 AWG BELDEN 6120UL <br /> ARxx 2WAY SMARTRESCUE POWER SUPPLY 2500-PWR24U RATH INCLUDED-8.78"H X 12.29"W X 2.81"D SHALL MAINTAIN A MINIMUM SEPARATION OF 48 INCHES HORIZONTALLY&12 INCHES () <br /> RP7700104 VERTICALLY BETWEEN OUTGOING AND RETURN CIRCUITS. 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] <br /> © 2WAY SMARTRESCUE SUB STATION 2100-956SR RATH INCLUDED-7.25"H X 4.75W X 1.875"D NOTE:ALL LISTED RESISTANCE AND CAPACITANCE ARE CONDUCTOR TO CONDUCTOR.ALL <br /> STAINLESS STEEL,SURFACE MOUNT 8. ALL PULL STATIONS AND NOTIFICATION DEVICES SHALL BE MOUNTED AT HEIGHTS SPECIFIED RESISTANCE VALUES ARE PER 1000 FEET. ABBREVIATIONS <br /> PER NFPA 72 AND ADA REQUIREMENTS. <br /> 9. ALL DETECTOR SPACING SHALL BE PER NFPA 72&LOCAL CODES. AC-ABOVE CEILING FSD-FIRE SMOKE DAMPER(THIRD PARTY) <br /> AFF-ABOVE FINISHED FLOOR HVAC-HEATING,VENTILATION,AND AIR <br /> 10. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ROUGH-IN LOCATIONS WITH OTHER Sheet List Table ADA-AMERICAN DISABILITIES ACT CONDITIONING(THIRD PARTY) <br /> TRADES. Sheet Number Sheet Title AHJ-AUTHORITY HAVING JURISDICTION LA-LOW AIR(THIRD PARTY) <br /> FA-0-1 COVER SHEET AHU-AIR HANDLING UNIT(THIRD PARTY) N/A-NOT APPLICABLE <br /> FA-0-2 NOTES ASD-ASPIRATION SMOKE DETECTION NAC-NOTIFICATION APPLIANCE CIRCUIT <br /> 11. ALL FIRE ALARM DEVICES SHALL BE SECURELY FASTENED TO WALLS OR CEILINGS. FA-1-1 LEVEL 1 CD-CANDELA(EX.15CD) NFPA <br /> FA-1-2 LEVEL2 NIC- <br /> -NATIONAL FIRE PROTECTION ASSOCIATION <br /> 12. SMOKE DETECTORS SHALL NOT BE LOCATED CLOSER THAN 36"TO ANY AIR REGISTER OR FA-1-3 LEVEL 3 CIS-COMMON INTELLIGIBILITY SCALE <br /> DIFFUSER. FA-1-4 LEVEL 4 DH-DOOR HOLDER(THIRD PARTY UNO) NTS-NOT IN CONTRACT <br /> NOT TO SCALE <br /> FA-2-1 RISERS EF-EXHAUST FAN(THIRD PARTY) PS-POWER SUPPLY <br /> FA-3-1 FIRE PANEL DETAILS ELEV-ELEVATOR(THIRD PARTY) RTU-ROOF TOP UNIT(THIRD PARTY) <br /> 13. HEAT DETECTORS SHALL NOT BE LOCATED CLOSER THAN 36"TO ANY AIR REGISTER OR FA-3-2 ANNUNCIATOR DETAILS EOL-END OF LINE SLC-SIGNALING LINE CIRCUIT <br /> DIFFUSER. FA-4-1 DEVICE DETAILS <br /> FA-4-2 DEVICE DETAILS EPF-ELEVATOR PRESSURIZATION FAN(THIRD PARTY) SPF-STAIR PRESSURIZATION FAN(THIRD PARTY) <br /> FA-4-3 UIO DETAILS FA-FIRE ALARM STI-SPEECH TRANSMISSION INDEX <br /> 14. PER NFPA 72,CHAPTER 17;SMOKE DETECTORS INSTALLED PRIOR TO FINAL CLEAN MUST BE FA-5-1 CALCULATIONS FAA-FIRE ALARM ANNUNCIATOR TYP-TYPICAL <br /> CLEANED AND VERIFIED TO BE OPERATING IN ACCORDANCE WITH THE LISTED SENSITIVITY,OR FA-5-2 CALCULATIONS FACP-FIRE ALARM CONTROL PANEL UNO-UNLESS NOTED OTHERWISE <br /> THEY SHALL BE REPLACED PRIOR TO THE FNAL COMMISSIONING OF THE SYSTEM. FA-5-3 I CALCULATIONS FACU-FIRE ALARM CONTROL UNIT VAV-VARIABLE AIR VOLUME(THIRD PARTY <br /> CONVERGINT BEARS NO RESPONSIBILITY FOR LABOR OR MATERIAL ASSOCIATED WITH FA-6-1 TYPICAL RISER-2-WAY COMMUNICATION (T ) <br /> CLEANING,SENSITIVITY TESTING OR REPLACEMENT OF SMOKE DETECTORS INSTALLED PRIOR FA-6-2 DETAILS&BOM-2-WAY COMMUNICATION FA7C-FIRE ALARM TERMINAL CABINET VFD-VARIABLE FREQUENCY DRIVE(THIRD PARTY) <br /> FB0-FURNISHED BY OTHERS W/-WITH <br /> TO FINAL CLEANING. FCU-FAN COIL UNIT(THIRD PARTY) W-WATT(EX.1/2W) <br /> 15. HEAT DETECTORS SHALL NOT BE LOCATED CLOSER THAN 36"TO ANY HEAT GENERATING FFT-FIREFIGHTER'S TELEPHONE WP-WEATHERPROOF <br /> DEVICE(FUSES,BOILERS,WATER HEATERS,ETC.)IN MECHANICAL ROOMS. FM-FACTORY MUTUAL XP-EXPLOSION PROOF <br /> RIEV JON-DESCRIPTION DATE <br /> 16. HEAT DETECTORS SHALL NOT BE LOCATED CLOSER THAN 18"TO ANY PART OF ANY LIGHT FLOOR PLAN KEY ISEUED FOR PERMITJM <br /> FIXTURE. <br /> DEVICE ADDRESS KEY DETAIL BUBBLE KEY <br /> 17. HEAT DETECTORS SHALL BE MOUNTED WITHIN 24"OF A SPRINKLER HEAD WHEN USED FOR <br /> ELEVATOR SHUNT TRIP IN ELEVATOR MACHINE ROOMS&SHAFTS. L DETAIL NUMBER <br /> FIRE ALARM PANE # <br /> 18. INITIATING AND SIGNALING CIRCUITS MAY BE RUN IN SAME CONDUIT. DEVICE ADDRESS 4DETAIL <br /> s ////19. ALL CONDUCTORS SHALL BE LABELED BY ZONE OR SLC LOOP NUMBER. z-x-xxzz-x LOCATION I- SAME SHEET) <br /> p 20. THESE DRAWINGS ARE INTENDED TO SHOW PROJECT SPECIFIC PANELS,DEVICES AND WIRING DATACARD, _ISOLATED <br /> REDBRANCH <br /> U DEPICTED DIAGRAMMATICALLY.WIRING SHOWN IS NOT INTENDED TO DEPICT RACEWAY OR LOGICAL ADDRESS (A ) JPMES M. <br /> p PATHWAY LOCATIONS.DEVICE AND PANEL LOCATIONS SHALL BE COORDINATED BY INSTALLING PROJECT DESIGNER: <br /> JCONTRACTOR AS PART OF THE CONSTRUCTION PROCESS. <br /> Q NOTIFICATION DEVICE CIRCUIT KEY DRAWING SHEET INDEX KEY Dsa J <br /> U 21. ALL REFERENCES TO INTERNATIONAL BUILDING CODE(IBC)ARE FROM THE 2015 EDITION.ALL As slJowN DATer <br /> oa-is-zoz< <br /> U REFERENCES TO NFPA 72 ARE FROM THE 2013 EDITION AS CURRENTLY ADOPTED BY IBC.THE SPEAKER CIRCUIT NUMBER FIRE ALARM �LEVEUFLOOR/AREA <br /> Q ADOPTED VERSION FOR THE PROJECT JURISDICTION MAY BE DIFFERENT AND UPON REQUEST CIRCUIT <br /> In CONVERGINT WILL PROVIDE UPDATED REFERENCE SECTIONS TO MATCH ADOPTED VERSION. CIRCUIT NUMBER SIR FA-X.XX COMPASS HEALTH EVERETT <br /> XXW <br /> � THE SCOPE SECTION OF OUR DRAWINGS WILL PROVIDE THE VERSION REFERENCED FOR THE POWER SUPPLY FIRE ALARM <br /> SUFFIX Eel! � <br /> FIRE ALARM DESIGN. � 0=COVER SHEET 3322 BROADWAY <br /> 7 NX-.X.X 1=FLOOR PLANS <br /> x 22. AS THE FIRE ALARM VENDOR UTILIZED FOR THIS BUILDING,NFPA 72 REQUIRES WE KEEP `\ 2-RISER DIAGRAMS EVERETT,WA,98201 <br /> ACCURATE RECORD DRAWING INFORMATION.AS SUCH,IT IS NECESSARY THAT WE DEPICT LOGICAL DEVICE NUMBER 3=FIRE PANEL DETAILS <br /> EXISTING DEVICES AND WIRING IN ADDITION TO THOSE COMPONENTS ASSOCIATED WITH YOUR 4 5-DEVICE DETAILS <br /> =CALCULATIONS <br /> � SCOPE WHERE APPLICABLE.UNLESS OTHERWISE NOTED,IT IS ASSUMED EXISTING 6=2-WAY COMMUNICATION <br /> 0 COMPONENTS WILL REMAIN UN-DISTURBED BY YOUR OFAID IN IDENTIFYING <br /> Z NEW S.EXSTNG,WE WILL TURN EXISTING CO PONEN SPTOALIGHTERSHADE.REMOVAL F COVER SHEET <br /> U THE EXISTING DEVICES AND WIRING MAY OTHERWISE IMPACT THE CONTEXT OF THE <br /> COMPLETE,CODE REQUIRED FIRE ALARM SYSTEM,THEREFORE THEY CANNOT BE OMITTED <br /> Z FROM OUR DRAWING PACKAGE. FIRE ALARM SYSTEM <br /> WING. <br /> o FA-0-1 <br /> tL <br />