Tenant Name
COMPASS HEALTH
Permit
E2311-160
Year
2023
Notes
ELECTRICAL FOR New buildout of Compass Health building
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHEET NOTES: FLAG NOTES OX : INNp <br /> A. ALL RECEPTACLES IN AREAS ACCESSIBLE TO CLIENTS ANDI OR THE 1. 50%OF RECEPTACLES IN OFFICE AREAS,PRINTER LOCATIONS,STAFF 7. FIELD VERIFY ALL RECEPTACLE LOCATIONS IN STAFF LOUNGE WITH 15. PROVIDE GFCI PROTECTION FOR ALL RECEPTACLES IN LAUNDRY ROOM. <br /> PUBLIC ARE TO BE UL LISTED TAMPER RESISTANT AS PER THE BREAK ROOMS AND CONFERENCE AND MEETING ROOMS ARE TO BE CABINETRYAND FINALAPPLIANCE LOCATIONS. PROVIDE GFCI-TYPE BREAKERS FOR WASHERS AND DRYERS.SEE PANEL <br /> REQUIREMENTS OF NEC 406.12(5). SWITCHED. SCHEDULE.FIELD VERIFY FINAL APPLIANCE LOCATIONS WITH <br /> 8. PROVIDE 20-AMP,125V,TAMPER-RESISTANT DUPLEX RECEPTACLES WITH ARCHITECT. <br /> B. SEE MECHANICAL CONNECTIONS PLANS FOR CONNECTION FOR NON-GFCI AND NON-USB DEVICES,RECEPTACLES ARE TO BE TWO USB TYPE A CHARGING OUTLETS AT RECEPTACLE LOCATIONS <br /> REQUIREMENTS FOR ALL MECHANICAL AND PLUMBING EQUIPMENT. HALF-SWITCHED.SWITCHED PORTIONS OF RECEPTACLES ARE TO BE INDICATED. :16. PROVIDE FLUSH-MOUNTED REMOTE GENERATOR/ATS ANNUNCIATOR. Ay <br /> AUTOMATICALLY CONTROLLED PER ENERGY CODE REQUIREMENTS VIA FIELD VERIFY LOCATION WITH ARCHITECT.ANNUNCIATOR TO BE FED VIA <br /> C. AREAS ABOVE CEILINGS IN PROJECT ARE BEING USED AS RETURN AIR THE LIGHTING CONTROL SYSTEM OCCUPANCY SENSOR.SWITCHED 9. COORDINATE INSTALLATION OF RECEPTACLE WITH CABINETRY. DC CIRCUIT FROM GENERATOR;CONNECT COMPLETE PER CODE AND <br /> PLENUMS.CONTRACTOR TO USE PLENUM RATED CABLE/INSTALLATION OUTLETS ARE TO BE LABELED WITH MANUFACTURER-INSTALLED MANUFACTURER'S INSTRUCTIONS. <br /> TO MEET CODE REQUIREMENTS. ENGRAVED POWER SYMBOL AND"CONTROLLED"TEXT. 10. INSTALL AND CONNECT COMPLETE MAGNETIC HOLD OPEN AT ELEVATOR <br /> SMOKE DOORS/CURTAINS.COORDINATE EXACT CONNECTION 17. INSTALL AND CONNECT COMPLETE MAGNETIC HOLD OPEN ON DOOR. <br /> AT GFCI TYPE RECEPTACLES AND RECEPTACLES WITH USB CHARGING REQUIREMENTS AND LOCATIONS WITH ARCHITECT.COORDINATE WITH COORDINATE EXACT CONNECTION REQUIREMENTS AND LOCATIONS WITH <br /> OUTLETS,PROVIDE A FULLY SWITCHED AND FULLY UNSWITCHED FIRE ALARM CONTRACTOR;SMOKE DOORS/CURTAINS TO BE CONNECTED ARCHITECT.COORDINATE WITH FIRE ALARM CONTRACTOR;CONNECT TO <br /> RECEPTACLE ADJACENT TO EACH OTHER PER ENERGY CODE TO THE FIRE ALARM SYSTEM PER CODE AND AHJ REQUIREMENTS. THE FIRE ALARM SYSTEM PER CODE AND AHJ REQUIREMENTS. 4 • S <br /> REQUIREMENTS.RECEPTACLES MARKED'C'INDICATE FULLY <br /> isan <br /> CONTROLLED DUPLEX RECEPTACLES 11. PROVIDE RECEPTACLE FOR BELOW COUNTER MICROWAVE IN CABINETRY 18. PROVIDE POWER CONNECTION FOR MOTORIZED FIRE CURTAIN AT <br /> SHELVING,+24'AFF.SEE ARCHITECTURAL ELEVATIONS.FIELD VERIFY PHARMACY WINDOW;INSTALL AND CONNECT COMPLETE PER CODE AND 38 NORTHWEST DAVIS,SUITE 300 <br /> 2. PROVIDE FLUSH-MOUNTED 2-GANG FLOOR BOXES WITH ROUND EXACT LOCATION WITH CABINETRY. MANUFACTURER'S INSTRUCTIONS.CONFIRM CONNECTION PORTLAND,OR 97209 <br /> ACTIVATION;LEGRAND WIREMOLD RFB2E OR PRE-APPROVED EQUAL. REQUIREMENTS AND LOCATIONS WITH EQUIPMENT PROVIDERS PRIOR TO 503,245,7100 <br /> CONTRACTOR TO PROVIDE REMOVABLE BARRIERS IN EACH FLOOR BOX 12. PROVIDE FLUSH-MOUNTED 4-GANG FLOOR BOXES WITH ROUND ROUGH-IN.LOW VOLTAGE CONTRACTOR TO CONNECT TO FIRE ALARM <br /> AND 1-INCH CONDUIT WITH PULLSTRING FROM EACH FLOOR BOX TO ACTIVATION;LEGRAND WIREMOLD RFB4E OR PRE-APPROVED EQUAL. SYSTEM PER CODE AND AHJ REQUIREMENTS. ® 1506 STH AVE,SUITE 300 <br /> NEAREST FURRED OUT WALL THEN UP INTO ACCESSIBLE CEILING SPACE CONTRACTOR TO PROVIDE REMOVABLE BARRIERS IN EACH FLOOR BOX SEATTLE,WA 98101 <br /> FOR TELECOM SYSTEMS INSTALLATION.IDENTIFY THE SPECIFIC FLOOR AND 1-INCH CONDUIT WITH PULLSTRING FROM EACH FLOOR BOX TO 206.576.1600 <br /> BOX SERVED WITH PERMANENT LABELS ON THE END OF EACH CONDUIT NEAREST FURRED OUT WALL THEN UP INTO ACCESSIBLE CEILING SPACE 1014 HOWARD STREET <br /> USING POSITION RELATED TO GRID LINES AS IDENTIFIERS.CONFIRM LOW FOR TELECOM SYSTEMS INSTALLATION,IDENTIFY THE SPECIFIC FLOOR SAN FRANCISCO,CA M103 <br /> VOLTAGE SYSTEM REQUIREMENTS WITH LOW VOLTAGE DESIGN-BUILD BOX SERVED WITH PERMANENT LABELS ON THE END OF EACH CONDUIT 415.252.7063 <br /> CONTRACTOR.COORDINATE DEVICES LOCATIONS AND ROUTING OF USING POSITION RELATED TO GRID LINES AS IDENTIFIERS.CONFIRM LOW mANKROM MOISAN ARCHITECTS,INC. <br /> CONDUITS WITH STRUCTURAL AND ARCHITECT.SEE ARCHITECTURAL VOLTAGE SYSTEM REQUIREMENTS WITH LOW VOLTAGE DESIGN-BUILD <br /> FLOORPLANS FOR DIMENSIONED LOCATIONS. CONTRACTOR.COORDINATE DEVICES LOCATIONS AND ROUTING OF SIDER+BYERS ASSOCIATES,INC. <br /> CONDUITS WITH STRUCTURAL AND ARCHITECT.SEE ARCHITECTURAL �(�\ <br /> 3. FIELD VERIFY RECEPTACLE LAYOUT IN EXAM ROOMS WITH FINAL FLOORPLANS FOR DIMENSIONED LOCATIONS. MECHANICAL AND ELECTRICA <br /> EQUIPMENT LOCATIONS.COORDINATE WITH ARCHITECT.TYPICAL. 192 NICKERsoN,SUITE 300 <br /> SEATTLE,WA 98109 <br /> 13. FIELD VERIFY FINAL LOCATION OF RECEPTACLE FOR MONITOR WITH 2O6.265.2966 <br /> 4. PROVIDE GFCI TYPE BREAKER FOR REFRIGERATOR,MICROWAVE, ARCHITECT. <br /> DISPOSAL,AND DISHWASHER CIRCUITS.CONFIRM EXACT RECEPTACLE <br /> LOCATIONS WITH FINAL APPLIANCE LOCATIONS AND CABINETRY 14. ALL ELECTRICAL DEVICE COVER PLATES IN AREAS ACCESSIBLE TO <br /> INSTALLATION. PATIENTS ON LEVELS 3 AND 4 ARE TO BE HIGH-ABUSE.COVER PLATES <br /> ARE TO BE HIGH STRENGTH POLYCARBONATE OR POLYCARBONATE/ <br /> S. FIELD VERIFY EXACT LOCATION OF RECEPTACLE FOR UC REFRIGERATOR NYLON BLEND WITH TAMPERPROOF SCREWS IN EACH CORNER OF THEPASS <br /> WITH CABINETRY AND EQUIPMENT PROVIDER.. COVER PLATE.PROVIDE CORTECH USA TIGER PLATES OR 1 v PRE-APPROVED EQUAL COMPATIBLE WITH DEVICES TO BE INSTALLED IN <br /> 6. REFRIGERATOR RECEPTACLE EXEMPT FROM ENERGY CODE THESE AREAS. Health <br /> CONTROLLED RECEPTACLE REQUIREMENTS.RECEPTACLE TO BE - <br /> UNCONTROLLED. U <br /> 0LUT S <br /> ^ development partners <br /> L3-32 L�3V _ _ _ _ _ _ _ 3Pd7 L3P-47 F�9 3Pd9 L P51 L3P-53 P: -- L3P-7 L3P59 _ _�p <br /> 6 L3P 9032 6 c 13-28 OP•67 _ ___ L3P•53 L3P- L3P <br /> C,L3P,32 L3P-$9 -- L3P-20 7 L3P19 L3P-51 L3P 53 L3P-55 Lt il <br /> -59 <br /> g I_L3P-30 gg <br /> 3 C,L3P-32 L3P58 C'L32- _- L3Pd - L3P-67 L3P571 L3P57 <br /> , C,L3P-38 L3P-67 <br /> I - $P-65 G L3P•50 <br /> �J g L3 30 L P.: <br /> L3P-L3P <br /> - L3P <br /> L3P40 t] FI <br /> L3P-73 _ <br /> L3P7 =_ L3P-28' L3P-20 P-20 __ 53 L3P-73 L3P 4 -_- _- OL3P-25- L3P-50 <br /> L3P-32 GFI- - L3P I OP-61 P-73 OP•73 ' 702 GFI <br /> - _ GFI _--_ GFI 0-54 L3P <br /> GFI 7 L3 0 IL3 GFI L3P-67 1 - 1 L3P-50 <br /> L3P-28 L3P-L3P ' GFI L3P-73 L3P-73 I L3P-54 <br /> -- .. 15 43P-2_ L3P-20 = L3P-6 L3P-77 5 <br /> I <br /> N „' - <br /> E5.01 <br /> _ <br /> 5 UC FRIDGE - pP-24,28 L3P-7 L3P-T7 1 _ OP•52 L3P5 — <br /> 702,OL3P-20 -. _ L3P•20� <br /> LP <br /> W� 702 <br /> _ <br /> 10 L3P-18 L3P L3P-04 L3P-46 L17� 3P52 y <br /> •15 M=1 <br /> -—-—- - - - - - - - .._.. L 56�,5 ,,55 L3P-04 2 3P L2P-0 = N\ / L3P L3P-44 j 3P�8 _ L3P-58 L3P-5fi YL3 i18 \ 1 -L_ -- <br /> / \ L3P-18 L3P-46 -� L3P-58 DN/ \ L3P 6 V <br /> LAM 10 LAM , L P•7 1_,I' L8 L3P-58 L3P-56L30.8 1 L3P48.iOP-48 L3 GF6 -- _j ILL <br /> mW_ <br /> xs _� <br /> _ _ L3P-189� <br /> L3P-13 OL 1 QQ <br /> 31 13R-1- - - SECURITYF c --- _ 74 E5.04 OL3P-29 13 Tv,+.11 Q Q <br /> Ip -P-11 TYPICAL O DD 0_ <br /> L3P-13 <br /> N 0 <br /> M CJ <br /> L3P �OL3P-29 1 m M U <br /> - 13 N,+72- OL3P-27 <br /> 1 L3P-15 00P-27 -- - <br /> 17i' L3P 1 REVISION DATE REASON FOR ISSUE <br /> 9 2 OB.08.22 `PERMIT REVISIONS - <br /> L3P-9 L3P-3 OL3P-29 - <br /> 'I S 0920.22 GMP ADDENDUM <br /> '�F 4 1020.22 A51-01 <br /> DN L3P-15 10 P•19 L PFI `J - <br /> n <br /> 21 X II 702 <br /> }_-_ --- - `- --J _-' ` - - �� OCI APPROVAL STAMP <br /> ,. S <br /> 13 N,+72' OL3P-5 OL3P•19 <br /> L3P-7 �P-70P 3P-7 P 7 - 13 AB,702 ® 70 1 <br /> OL3M-31 702 70 <br /> 18 702 OL3P-13 L3P-23 L3P- <br /> C,702 <br /> OL3P-1 OL3P-1 1 OL 1 L 1 OL3P -- P-15 <br /> 702 `'- 702 7 70 70 P502 7 702 O 02 21 J` J L3 1-13 P-17, L3P-17 3P-31 - L3P.35 9 L3P-33 <br /> LLL70 OL3P-15 702 p <br /> ' 702 iD 0 P-15 70 - L3P-23F25 1 L3P5 <br /> L3P�5__ 0 - p., L3P-27,29 L3P� LEVEL 3 FLOOR <br /> 0P.13 Q 16 1 N,+72"13 <br /> Li 2OL3P-9 3P-31 L3P. -35 <br /> UC,702 OL3P-15 043P.17 OL3P-13 L3P-17 �-79`e� OP-31 QP-35 PLAN- POWER <br /> U - - - - - - -- - - - - - - - - 00P-7_ _ --- _L3�PT21 - - - - 3P� riff -—-—O PLAN <br /> 1 1 1 1 15 1 ASI-04 SET <br /> A 6 <br /> D C DATE PROJECT NUMBER <br /> N LEVEL 3 FLOOR PLAN - POWER PLAN �qaq 10.20.2022 21o1B - <br /> SHEET ' <br /> SCALE:1/S'=1'-0' KEY PLAN NUMBER <br /> E2.03 <br /> 0 4 6 16 32 <br />