Laserfiche WebLink
NA r <br /> �N <br /> Ali <br /> Do400 s9 <br /> lL <br /> ��^U7 <br /> ANAL <br /> 1 <br /> TELEVISION,WALL-MOUNTED aQP <br /> 4 38 NORFMN BT MNS,51111E 300 <br /> FINISHED GRADE/PAVING AND SUBSTRATES PORTIAND,OR 972M <br /> Q FFA-C-Pl PER CIVILI ARCHITECTURAL PLANS 503.245.7100 <br /> ALL DEVICES SHOWN WITHIN ONE _ 1505 51H AVE,sunE 300 <br /> Ppp STUD BAY OF EACH OTHER BUT AT �� sEA7U.WA M101 <br /> DIFFERENT MOUNTING HEIGHTS — zoas7a.16o0 <br /> WWW ARE TO BE VERTICALLY ALIGNED <br /> JN — — _ 1014 HOWARD STREET <br /> 4$44vvv� UNLESS CODE OR ARCHITECT ��—I CONDUT SAN FRANOSOO,CA 94103 <br /> ( )��� 84" 86" REQUIRES OTHERWISE. w :. III—� �— 415.zsz.7063 <br /> ABOVE COUNTER AB 78" F _F III—III—III— <br /> z>— z2 COMPACTED BACKFILL.SEE EARTHWORK <br /> ®ANNROM MOIWI AR01ffECR,INC <br /> MATCH DOOR LEVER HEIGHT fib" swz� sws= —HI=lIII-II� <br /> �fw� SPECIFICATIONS FOR REQUIREMENTS. <br /> cl . 9�— �_IIl= SIDER+BYERS ASSOCIATES,INC. <br /> 44" 48' iSo zSJo —I—_ E[�\ <br /> �pFU �p�U MEONNIp1 ANO EtfQRIG1 „ <br /> 36" III—III—III 192 NORSON,SUITE 300 <br /> wv34� VP -I II III FOIL-BACKED MARKER TAPE TO BE INSTALLED ALONG THE ENTIRE SFAT E WA9N109 <br /> III=I EMI57,U1= FINISHED GRADE.LABEL"DANGER:HIGH VOLTAGE CABLE"OR TYPE LB CONDUIT BODY WITH GASKET 206.295.2966 <br /> 18" LENGTH OF THE CONDUIT.CENTER ON TRENCH 18-INCHES BELOW <br /> I FINISHED FLOOR — — <br /> "WARNING:UNDERGROUND CABLE"AS APPLICABLE. SEAL COUNTER FLASHING <br /> 00 <br /> WEATHERTIGHT TO CONDUIT <br /> DETAIL NOTES: 8-INCHES OF CLEAN SAND ORPRE-APPROVED CLEAN EARTH CUSHION <br /> EAL <br /> I_ NE PIECE COLLAR <br /> A. THIS DETAIL IS DIAGRAMMATIC AND MEANT TO SHOW GENERAL LOCATIONS ONLY;NOT ALL PARTS AND PIECES ARE SHOWN. 3"MIN. - _ SPECIFICATIONS AND UTILITY PROVIDER REQUIREMENTS. SEAL WEATHERTIGHT <br /> THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL PARTS,PIECES,SUPPORTS,ETC REQUIRED FOR A COMPLETE AND O S <br /> AROUND CONDUIT(S)IN ALL DIRECTIONS.SEE EARTHWORK C MPASS <br /> FULLY OPERATIONAL SYSTEM. =III OOFING BY GENERAL <br /> CONTRACTOR <br /> B. MOUNTING HEIGHTS SHOWN IN THE ARCHITECTURAL DRAWING SET TAKE PRECEDENCE OVER THOSE SHOWN HERE.THE —_ �p� <br /> CONTRACTOR SHALL REFER TO THE ARCHITECTURAL DRAWINGS PRIOR TO ROUGHING IN ANY DEVICES.INFORM ENGINEER -I I I=I I I' —� -III EE PLANS AND RISERS l.. <br /> AND ARCHITECT OF CONFLICTS. <br /> 3 FOR QUANTITIES AND SIZES <br /> C. MOUNTING HEIGHTS SHOWN HERE ARE TO THE TOP OF DEVICE BOXES UNLESS NOTED OTHERWISE. DETAIL NOTES: MIN. NOTES: CONDUIT—"' <br /> D. WHERE DEVICES ARE SHOWN ON THE PLANS ABOVE DOORS,SAID DEVICES SHALL BE CENTERED HORIZONTALLY ON THE A. BEE PLANS AND RISER DIAGRAMS FOR QUANTITIES AND SIZES OF CONDUIT AND CONDUCTORS. LOT U S <br /> DOOR OPENING UNLESS OTHERWISE NOTED OR DIRECTED BY THE ARCHITECT. A. ELECTRICAL CONTRACTOR TO PROVIDE ARCHITECTIROOFING CONTRACTOR <br /> B. ALL UTILITY INFRASTRUCTURE IS TO BE INSTALLED PER CODE AND UTILITY REQUIREMENTS.SEE APPROVED CONDUIT COLLAR AND FLASHING. d2V2(O(JR1ent partners <br /> E. ALIGN THE TOPS OF ALL BOXES INDICATED AS BEING INSTALLED MOUNTED AT THE SAME MOUNTING HEIGHT. TPU STANDARD C-UG-1100.COORDINATE TELECOM UTILITY PROVIDER REQUIREMENTS WITH <br /> TELECOM UTILITIES. B. USE THIS DETAIL ONLY WHERE REQUIRED.STUB-UP THROUGH MECHANICAL <br /> EQUIPMENT ROOF CURBS WHEREVER POSSIBLE. <br /> C. THE CONTRACTOR SHALL COORDINATE WITH THE UTILITY SERVICE PROVIDERS FOR INSPECTION <br /> OF ALL UTILITY INFRASTRUCTURE PRIOR TO COVER AS REQUIRED BY THE SERVICE PROVIDERS. <br /> ELECTRICAL DEVICE MOUNTING DUCT BANK INSTALLATION CONDUIT ROOF PENETRATION <br /> N.T.S. N.T.S. N.T.S. <br /> 2"X4"HANDHOEL POLE AS SPECIFIED <br /> WITH COVER ROUND LUG INSIDE POLE WITH <br /> #8 AWG SOLID CU CONDUCTOR <br /> BOLT COVER TO GROUND ROD <br /> OOFTOP MOUNTED <br /> NUT AND WASHER TO PLUMB POLE ",,---BASE ATE AND ANCHOR MECHANICAL EQUIPMENT <br /> (TWO EACH PER ANCHOR BOLT) BOLTS BY MANUFACTURER <br /> �_---(2)#4 TIES WITHIN TOP 5"OF PIER OOFTOP EQUIPMENT W <br /> LIQUID TIGHT FLEXIBL CURB CAP <br /> 2'-0"MAX WIRING TO MOTOR = o <br /> BY DIV.26 N <br /> a � <br /> FINISH Q <br /> GRADE UILT-UP ROOF CURB V <br /> +a' ELECTRICAL CONDUITS O <br /> f J Of <br /> W <br /> AS REQUIRED CONDUIT FOR CCTV CAMERA WHERE SHOWN m <br /> ON ELECTRICAL SITE PLAN AND SPARE CONDUIT > <br /> BY STRUCTURAL RISER DIAGRAM W F <br /> ENGINEER EATHERPROOF DUPLEX GFI Q } <br /> CONCRETE FOUNDATION RECEPTACLE-FEED THROUGH <br /> Q <br /> BACK OF BOX.INSTALL WHERE 2 <br /> SHOWN ON PLANS Q DIV.26 FURNISHED STARTER, Of <br /> INSTALLED AND CONNECTED BY O m d <br /> 3/4"x 10'-0"COPPER CLAD DN.26 ON OUTSIDE OF UNIT O <br /> STEEL GROUND ROD 21 CUTE CONDUITS INSIDE <br /> NOTES: BUILT-UP ROOF CURB <br /> A. LUMINAIRES TO HAVE A FINAL MOUNTING HEIGHT OF AS INDICATED IN LUMINIAIRE SCHEDULE. <br /> gEVISION GATE _PEASON FO,i ISSUE <br /> B. THIS DRAWING IS DIAGRAMMATIC TO SHOW DESIGN INTENT FOR LIGHT POLE BASES.THE NOTES: _2 Ds 20 22 GNP ADDENDUM <br /> ELECTRICAL CONTRACTOR SHALL HIRE A STRUCTURAL ENGINEER CURRENTLY REGISTERED IN A. MAINTAIN CODE CLEARANCE IN FRONT OF ALL DISCONNECT SWITCHED AND JUNCTION BOXED.DO <br /> THE STATE OF WASHINGTON TO ENGINEER ALL LIGHT POLE BASES(POLES,ANCHOR BOLTS, NOT MAINTAIN <br /> BLO C ACCESS PANELS,DOORS OR ALL DISCONNTENA WI ACCESS. <br /> FOUNDATIONS,ETC)TAKING INTO ACCOUNT SCHEDULED LUMINAIRE,MANUFACTURER'S <br /> INSTALLATION INSTRUCTIONS,SOILS CONDITION,ETC.FOR LIGHT POLES WITH PROVISIONS FOR B. ROUTE ALL CONDUIT(POWER AND CONTROLS)UP THROUGH EQUIPMENT CURB.SEAL CONDUITS <br /> FUTURE CCTV CAMERAS,THE CONTRACTOR'S STRUCTURAL ENGINEER SHALL ALSO TAKE THIS TO PREVENT WATER ENTERING BUILDING. SDO APPROVAL STAMP <br /> EQUIPMENT INTO ACCOUNT IN THEIR CALCULATIONS AND DESIGN.THE CONTRACTOR SHALL <br /> INCLUDE STAMPED FINAL POLE/POLE FOUNDATION DESIGN WITH THE LUMINAIRE SUBMITTAL. C. ALL ROOF TOP ELECTRICAL EQUIPMENT SHALL BE LISTED FOR WET LOCATIONS. <br /> POLE-MOUNTED <br /> LUMINAIRE POLE BASE DETAIL ROOFTOP HVAC EQUIPMENT WIRING <br /> C N.T.S. N.T.S. <br /> DETAILS <br /> GMP SET <br /> DATE PROIER NUMBER <br /> 09.20.2022 21016 <br /> SHEET NUMBER <br />