NOTES: 114 <br /> 2"IRRIGATION TO 1.SECURE BACKFLOW PREVENTION <br /> ROOF TERRACES DEVICES TO WALL AND PROVIDE <br /> SEE PLUMBING PLANS NORMALLY CLOSED REQUIRED CLEARANCE WALL BLOCKING PER STRUCTURAL ENGINEER <br /> 2.MOUNT RPBA'S AT A HEIGHT THAT 7106 <br /> ALLOWS THEIR DRAINS TO BE ROUTED WALL----,,, m�g°ti <br /> I r 1 LINE TO HUB DRAIN TO DRAIN. JOISTS OR STRUCTURE ONAV <br /> (FOR DRAINING INTERIOR SYSTEM) <br /> r 1¢ RPBA#2 tCpda ACE FITTING EQUAL <br /> IPI <br /> IRR I(J � # 90°-120 BR <br /> ° <br /> r UNION(TYP) PRESSURE GAUGE(TYP) TO GRINNELL FIG.112- <br /> 2"INCOMING IRR— iHII�Q�� f 1/2"0 BOLT TO YZ 1"N.P.T.(TYP,OF 4) 15/1 <br /> TM <br /> IRRIGATION ��DCVA#1 LRPBA <br /> BALL OR BUTTERFLY VALVE(TYP) INSULATION CONTINUOUS ��1"CHANNEL STRUCTURE 1"0 GALV.SCH.40SERVICE 1 THROUGH PIPE CLAMPS W/ TYP.OF 4I "UNISTRUT"OR ( ) PIPE I LENGTH)NON-COMPRESSABLE EQUALSUIT(TYP.OF 4)4"INCOMING r4"BUILDING INSULATEDINSERT. 1/2"0 BOLTBRACE FITTING EQUALWATER bl IIt�IIIDOMESTIC SECURE (TYP.OF 4) �Q�P TO BRACE <br /> FITTING <br /> FIG.UAL 38 NORTHWEST DAVIS,SUITE 300 <br /> SERVICE / ~SERVICE PIPING TO SUPPORTS �p�E G PORTLAND,OR 97209 <br /> - 12"MIN. HANGER RODS WITH"UNISTRUT"PIPE RN SQE 1"N.P.T.(TYP.OF 4) 503.245.7100 <br /> STRAINER(TYP) p'(E S• <br /> 60"MAX. CLAMP OR EQUAL. �MF� Q2 <br /> ROUTE DRAIN TO HUB DRAIN,� gE 1505 STH AVE,SUITE 300 <br /> ONE PER RPBA FLOOR 1-5/8"P-1001 2"X1/8"GALV.FLAT SEATTLE,WA 98101 <br /> 2"OUTGOINGS, HUB DRAIN "UNISTRUT"CHANNEL BAR AROUND WTR.HTR. NOTE:DO NOT STRAP AROUND WATER 206.576.1600 <br /> OR EQUAL.(TYPICAL) (TYP.OF 2 BANDS ONE HEATER'S INTEGRAL CONTROL PANEL.IRRIGATION HIGH,ONE LOW) <br /> 014 HowARD STREET <br /> TO LANDSCAPE POINT <br /> SAN FRANCISCO,CA 94103 <br /> OF CONNECTION NOTE:QUANTITY OF PIPES SHOWN REPRESENTATIVE ONLY, 415.252.7063 <br /> SEE LANDSCAPE. WATER SERVICE SCHEDULE PROVIDE QUANTITY OF PIPES REQUIRED. ©ANKROM MOISAN ARCHITECTS,INC. <br /> MARK MAKE MODEL SIZE NOTES SIDER+BYERS ASSOCIATES,INC. <br /> NOTE:VERIFY SIZING FOR SPECIFIC APPLICATION W/STRUCTURAL ENGINEER. MECHANICALAND <br /> ELECT192 RICAL <br /> SUITE 300 <br /> RPBP#1 AND#2 WATTS LF009 3" DUPLEX CONFIGURATION LEAD FREE SUSPENDED ELECTRICAL <br /> DCVA#1 WATTS LF007 2" FOR IRRIGATION,LEAD FREE WATER HEATER/ SEATTLE,WA 98109 <br /> z PIPE SUPPORT 206.265.2966 <br /> P4.03 N.T.S. 3 STORAGE TANK SEISMIC BRACING <br /> 4.03 N.T.S. <br /> INCOMING WATER SERVICE DETAIL C <br /> T4.03 N.T.S. ASJ <br /> Heallth <br /> L(JT U S <br /> V <br /> development partners <br /> INSULATION CONTINUOUS <br /> _ SUPPORT FROM STRUCTURE _______-_ � CONTROLLER W/24HR THROUGH PIPE CLAMPS. 1-5/8" <br /> TIME CLOCK W/NONCOMPRESSABLE CHANNEL <br /> EQUIPMENT = TEMPERATURE BALL VALVE(TYP) INSULATEDINSERT. <br /> SENSOR <br /> ISECURE <br /> PIPWTING TO H"NITRUT PPE <br /> RTS <br /> HOTWATER CHECK VALVECLAMP OR EQUAL <br /> RECIRC.LINE CIRC.PUMPFLE UNION(TYP)CO18" NOTE:QUANTITY OF PIPES SHOWN REPRESENTATIVE ONLY, <br /> PROVIDE QUANTITY OF PIPES REQUIRED. <br /> 5 DOMESTIC CIRC. PUMP DETAIL PIPE SUPPORT <br /> DRIP LEG — P4.03 N.T.S. <br /> P4.03 N.T.S. <br /> W <br /> GAS LINE Q <br /> 4 CONNECTION DETAIL a 00 <br /> P4.03 N.T.S. Y < <br /> 0 <br /> H <br /> J w <br /> Co0-1 <br /> w <br /> � w = <br /> H <br /> GRAVITY DRAINAGE TEMP SENSOR WELL TYP 3 Q J <br /> ( )PIPE SLOPED @ 4"STAINLESS STEEL GAS VENT(TYP) 3: W <br /> 1/8"PER FOOT 2 4"STAINLESS STEEL OMB.AIR TYP 0 _ <br /> (TYP) <br /> EMERGENCY BOILER Q U)1/4"PUMP OUTLET BALANCING VALVE#1 <br /> \\\ SHUT-OFF(BY E.C.) Q <br /> .� CP 0 ED a- <br /> d <br /> C4 2i <br /> 3"CW m O <br /> CEILING ----- �F- —120°HW------ m <br /> CHECK VALVE 3, <br /> — (TYP) <br /> 1/4"OUTLET TUBE r r� THERMOMETER(TYP) <br /> IN WALL —IUF®- v -----I-----------�-- ------------------------------------- ----- <br /> WALL MOUNTED SPLIT _ _ _ _ _ ___ _ <br /> BREATHER TUBE 2"HWC G G REVISION DATE REASON FOR ISSUE <br /> SYSTEM HEAT PUMP 3"CW r------ 1- --------- ------------ - T--- ---- 1 <br /> 3"HW ------ ��- 140°HW-------------- � i � 2 09.20.22 GMP ADDENDUM <br /> Q (2)1 1 4 G I I G G— <br /> C n I i I <br /> I I I`I ICI <br /> I I �}I <br /> SDCI APPROVAL STAMP <br /> EVAPORATOR COIL I 3"HW MAIN <br /> WATER SUBMETER.TO BE CONNECTED TO I I o- <br /> THE BUILDING ENERGY METER SYSTEM, <br /> COORDINATE CONNECTION WITH ELECTRICAL. V ! 3, <br /> CONDENSATE I r--- REDUCER I SET OUTPUT I SET OUTPUT I <br /> f(TYP) I TEMP.TO I SEISMIC BRACING TEMP.TO <br /> DRAIN TRAY <br /> DET 140°F. � PER UPC. (TYP) 140°F. � I <br /> — --------- I I 6"DIRT I <br /> L------_—_—_—_—_ 1—_—_—_J FD 2 ! LEG(TYP) i LJ 44"HOUSEKEEPING DETAILS <br /> PAD <br /> INLET TUBE W/FUNNEL I °I— -___J ! I °I— _---J <br /> MV-1 MV-2 J _ =j___ <br /> MANUFACTURER'S CONDENSATE PUMP o--RESERVOIR AT EACH UNIT <br /> r T/P RELIEF DRAIN GMP SET <br /> TO FLOOR DRAIN <br /> FD-2(TYP) CONDENSATE TO FLOOR A B <br /> WALL MOUNTED SPLIT SYSTEM 2"W,WITH 1-1/2"V DRAIN TO FLOOR DRAIN FD-2(TYP) <br /> r CONDENSATE DETAIL DRAINED-2(TYP) A <br /> D C DATE PROJECT NUMBER <br /> P4.03 N.T.S. m® S09 20.BER 21016 <br /> � CENTRAL PLANT - WATER HEATER DETAIL KEYPLAN <br /> 4.03 N.T.3. I o Everett Permit Services P4.O <br /> EVERETT Reviewed for Permit 04/15/2025 0 8 16 32 64 <br />