My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2600 FEDERAL AVE 2021 Plans 2025-09-29
>
Address Records
>
FEDERAL AVE
>
2600
>
Plans
>
2600 FEDERAL AVE 2021 Plans 2025-09-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2025 10:58:44 AM
Creation date
9/29/2025 10:55:41 AM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
2600
Permit
E2111-063
Year
2021
Notes
ELECTRICAL & COMMUNICATIONS & SITE LIGHTING-NORTON TERMINAL
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
x <br /> GENERAL NOTES <br /> 1. THIS PORTION OF SITE IS ACTIVE, THE OPERATION OF THE <br /> FACILITY WILL TAKE PRECEDENCE OVER THE WORK OF THE <br /> CONTRACTOR. IT IS THE RESPONSIBILITY OF THE <br /> CONTRACTOR TO COORDINATE CONSTRUCTION WITH OWNER'S <br /> PERSONNEL TO MINIMIZE DISRUPT10N TO THE FACILITY. <br /> 1. 5 TYPICAL i 2. OUTAGES ARE TO BE MINIMIZED. PROVIDE NOTIFICATION TO <br /> 2 I 1 OWNER'S PERSONNEL OF ANY IMMINENT POWER OR <br /> VS7C 1 N <br /> COMMUNICATIONS OUTAGES A MINIMUM OF 48 HOURS PRIOR <br /> 7 ° VS7P �9 4 TO OUTAGE. PROCEED WITH EACH OUTAGE ONLY AFTER <br /> E4.8 E5.6 1 / APPROVAL FROM OWNER'S PERSONNEL IS GIVEN. <br /> 3. DEMOLITION OF COMMUNICATIONS CABLING TO EXISTING <br /> COMMUNICATIONS POLE BY OTHERS. <br /> 6 CP10 �� `J - �� '� • - e —� x �— <0 4. CLEAN AND MANDREL ANY EXISTING CONDUIT PRIOR TO <br /> --•-- - r �-- -h - $ 8 _ -- - - - RE-USE. <br /> EXISTING FENCE I 2 EXISTING FENCE <br /> .. . . . <br /> KEYED NOTES <br /> --0.5 aS QS OS OS OS OS OS aS �S� QS� 6 OS OS OS �s 7.�� O$ <br /> (D DEMOLISH EXISTING HANDHOLES AFTER NEW <br /> \ � 1 COMMUNICATIONS POLE IS IN SERVICE. <br /> O SALVAGE EXISTING PORT COMMUNICATIONS POLE AND <br /> RETURN TO OWNER AFTER NEW COMMUNICATIONS POLE IS <br /> IN SERVICE, ABANDON POLE FOUNDATION IN PLACE. <br /> ¢�� s CL— O3 DEMOLISH THIS PORTION OF EXISTING CONCRETE ENCASED <br /> `< DUCT BANK WITH (1) 2"C POWER AND (1) 2' <br /> At COMMUNICATIONS. DEMOLISH PORTION OF CIRCUIT (2#8, <br /> w w W W 1#10G) FROM EXISTING COMMUNICATIONS POLE (KEYED <br /> _ NOTE 2) TO NEAREST HANDHOLE AS SHOWN ON E1.1 <br /> -- COORDINATE WITH OWNER FOR DE-ENERGIZING EXISTING <br /> CIRCUIT GS-NI-11 PRIOR TO DEMOLITION. <br /> i / <br /> Cv O DEMOLISH THIS <br /> PORTION EXISTING <br /> INTERFERES WITH NEW GATE INSTALLATION, OTHERWISE <br /> ABANDON IN PLACE. <br /> FEDERAL AVENUE ELECTRICA�C PLAN 1 —` Q5 PROVIDE STRUCTURAL BOLLARD PER SHEET C2.3. <br /> E1.1 E4.8 BOLLARDS SHALL BE SPACED A MAXIMUM OF 5-0" FROM <br /> EACH OTHER. SHOULD BELOW GRADE OBSTRUCTIONS <br /> INTERFERE WITH PLACEMENT, INCREASE QUANTITY OF <br /> - - BOLLARDS TO MAINTAIN SPACING REQUIREMENTS. <br /> © LOW-MAST COMMUNICATIONS POLE. <br /> �7 PROVIDE COMBINATION TRANSFORMER AND PANELBOARD <br /> (MPZ). CIRCUIT 2#8, #8G IN 2`C TO 4S1-2,4. <br /> ® PROVIDE ELECTRICAL CONNECTION TO GATE CONTROLLER. <br /> SEE SHEET C6.2 FOR FURTHER INFORMATION. COORDINATE <br /> WITH GATE SUPPLIER FOR CONNECTION REQUIREMENTS. <br /> FOR BIDDING PURPOSES PROVIDE 4#10 IN 1-C TO PANEL <br /> 4S1. <br /> O9 PROVIDE (1) 2-C POWER AND (1) 2"C COMMUNICATIONS <br /> WITHIN DUCT BANK. PORTION OF EXISTING DUCT BANK <br /> MAY BE REUSED IN LIEU OF NEW DUCT BANK IF EXISTING <br /> IS IN SATISFACTORY CONDITION. <br /> � 2 <br /> 8 16 <br /> , <br /> scale feet <br /> a <br /> s <br /> N � <br /> N EXISTING HANDHOLE PHOTO► IF SHEET IS LESS THAN 22x34 N Know what's below. REDUCE SCALE ACCORDINGLY <br /> _o Call before you dig. <br /> 0 <br /> mPROJECT ENGINEER: SCALE: <br /> E PORT OF EVERETT °"G " E4 8 � <br /> D. SIATERLIS AS NOTED <br /> Porto 1 E�CON Qti�a'�c°�p�!n DDIGSIATERLIS 05/07/2021 NORTON TERMINAL DEVELOPMENT CIP NO. <br /> ASSOCIATES,INC. �! 1—s-soo-05 0 <br /> ..w,u ENGINEERS—CONSULTANTS �` DRAWN M I CHECKED BY: Vl M T C A 3 R D INTERIM ACTION u. <br /> k,ms wnni��veim C. SMITH S. BARTKOSKE PROJECT Z <br /> of P.O. BOX 538 vzocl aaz osm�u l>.os)"�-0500 163DO HRJSTE wWOAJD,S E330 6/21/202 DKS FOR C FOR BID <br /> ��� ENLARGED ELECTRICAL PLAN Na. MT-NT 2021 02.2 <br /> naccrno.�rmua 16300 CHRISTENSEN ROAD,STE 330 / /07/202 OKS FOR Cltt REVIEW s�ONAL APPROVED�' FEDERAL A V E SHEET N0. 1 16 OF ,50 O <br /> (425)EVERE 2 WA 98206 SEATTLE,WA 98188 <br /> / (425) 259-3164 NO- DATE BY REVISION N0. DATE BY REVISION (�/$/2I <br />
The URL can be used to link to this page
Your browser does not support the video tag.