My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2600 FEDERAL AVE 2021 Plans 2025-09-29
>
Address Records
>
FEDERAL AVE
>
2600
>
Plans
>
2600 FEDERAL AVE 2021 Plans 2025-09-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2025 10:58:44 AM
Creation date
9/29/2025 10:55:41 AM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
2600
Permit
E2111-063
Year
2021
Notes
ELECTRICAL & COMMUNICATIONS & SITE LIGHTING-NORTON TERMINAL
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4- SQUARE TUBESTEEL <br /> FORMED STEEL CHANNEL <br /> n <br /> TYPICAL 4 FUSED I <br /> TYPICAL 2 SWITCH I INSTALL I I <br /> MANUFACTURER I�--- T r---� JFLIITYPICAL 3 (STAINLESS PROVIDED PUMP IIETERMPZ STEEL) STATION CONTROLI I I RANS <br /> PANEL III I I <br /> 5kVA I _Hp VFDs with III 1 1 1 1 <br /> REACTORS I I I <br /> 6' MIN 16"x16"x6" III I I I <br /> MINIMUM III u I I <br /> J-BOX 111 --- i L__-J 1 PROVIDE 100A 480/277V DISCONNECT, <br /> NEMA 4X I I I CIRCUIT TO TRANSFORMER VIA 2#1/0, <br /> I I t---, r--� <br /> III I I 1 #8G IN 1-1/2-C <br /> r6- MIN (TYPICAL) I I L—_J L_—J I PROVIDE ADDITIONAL I 1 4 SUPPORT AS <br /> PROVIDE 50 kVA 480-240/120V <br /> I I <br /> #2G -- A--------- i NECESSARY TO MOUNT 10 TRANSFORMER <br /> ISZ #4G IN 2"C <br /> CONTROL PANEL ABOVE <br /> -----_� SEAL OFF FITTINGS PROVIDE 200A 240/120V DISCONNECT, <br /> fft CIRCUIT TO TRANSFORMER VIA 3#3/0, <br /> GROUND WELL <br /> GENERAL NOTES <br /> 3/4'x10' <br /> SEAL OFF 0. 1. ALL TUBESTEEL AND FORMED STEEL CHANNEL SHALL BE <br /> GROUND FlTTING (TYP) <br /> ROD 6 HOT DIPPED GALVANIZED AFTER FABRICATION UNLESS NOTED <br /> L •�' SPARE CONDUff CAP (TYP) OTHERWISE. <br /> POWER CONDUITS ` 4s= 2. ALL BOLTS, NUTS, WASHERS AND OTHER MOUNTING <br /> SEE CIVIL PLANS SHALL BE SEPARATED <br /> FROM INTRINSICALLY s HARDWARE SHALL BE STAINLESS STEEL UNLESS NOTED <br /> NOTES: SAFE ZONE (ISZ) ® OTHERWISE_ <br /> '< 1. DETAIL MAY BE MIRRORED CONDUITS 3. PAINT ALL EXPOSED METAL SURFACES AND OVER TOP OF <br /> GALVANIZED ITEMS. <br /> 4. QUANTITY OF CONDUITS PER PLANS/ONE-LINE DIAGRAMS. <br /> TREATMENT ELECTRICAL KEYED NOTES <br /> COMPONENT MOUNTING ELEVATION K_1 � PORTABLE TRANSFORMER SKID <br /> E4.6 E5.3 E4.S E5.3 Ol PROVIDE CONCRETE PAD PER SHEET 51.3. <br /> O2 PROVIDE FLAT PLATE FITTINGS AS REQUIRED. <br /> O3 PROVIDE END CAPS ON ALL ENDS. <br /> ® PROVIDE CAPS. <br /> O5 PROVIDE 100A 3W 480V RECEPTACLE, SHALL MATCH <br /> RECEPTACLE AT PANEL 4P1. PROVIDE 50' OF #1/0 <br /> PORTABLE <br /> PROVIDE 5#10 IN 2" CONDUIT REECEPTACLEORD WITH MATCHING PLUGS TO THESE <br /> S. <br /> BETWEEN GUARD SHACK CONTROL PROVIDE 5#12 IN 2" CONDUIT BETWEEN <br /> PANEL AND GATE CONTROL CABINET GUARD SHACK CONTROL PANEL AND © PROVIDE 200A 4W 240V RECEPTACLE. PROVIDE 50' OF <br /> EACH GATE CONTROL CABINET #3/0 PORTABLE CORD WITH MATCHING PLUG AT ONE END, <br /> COORDINATE WITH OWNER WITH CORD REQUIREMENTS FOR <br /> 3 THER N ^ <br /> GUARD SHACK, COORDINATE LOCATIONPROVIDE CONTROL PANEL 7O PROVIDE SKID WITH GALVANIZED TYPE C STEEL CHANNEL <br /> OPEN OPEN OPEN AND GATE LABELS WITH OWNER FRAME AND DOUBLE GALVANIZED STEEL CHANNELS TO <br /> PUSHBUTTON, TYPICAL O O O SUPPORT EQUIPMENT (TRANSFORMER AND SWITCHES), <br /> CLOSE CLOSE CLOSE COORDINATE WITH OWNER FOR SKID REQUIREMENTS, <br /> EQUIPMENT HEWf1T SOUTH SOUTH GROUND CABLING REQUIREMENTS.REQU REMENTSGEMENT AND EPARATELY DERIVED <br /> SLIDING SLIDING ARM THE CONTRACTOR SHALL DESIGN A SKID FRAME THAT IS <br /> fl STAMPED BY A REGISTERED PROFESSIONAL ENGINEER IN <br /> THE STATE OF WASHINGTON AND SUBMITTED TO THE <br /> ENGINEER FOR APPROVAL. THE SKID FRAME SHALL BE <br /> uSUFFICIENTLY RIGID TO ALLOW TRANSPORT OF THE <br /> GATE CONTROL PANEL REQUIRED ELECTRICAL EQUIPMENT BY FORKLIFT. THE SKID <br /> o FRAME SHALL BE HOT-DIPPED GALVANIZED AFTER <br /> m E4.3 E5.3 FABRICATION AND COATED WITH 2 COATS OF WHITE PAINT. <br /> 0 8 PRO IDE 2 COMP SI 'SEM�S, WITH E 48 <br /> AND ONE 240V PORTABLE CORDS EACH. <br /> N L <br /> IF SHEET IS LESS THAN 22x34 W <br /> REDUCE SCALE ACCORDINGLY N <br /> N <br /> PROJECT ENGINEER SCALE, PORT OF EVERETT °W° NO. E5 3 "� <br /> 3 EIcO A I g•S� ED.S SIATERLIS NONE <br /> Porto I V d DEIGNED 9Y DATE <br /> 1 4 �N D. SIATERLIS os�o7/20z, NORTON TERMINAL DEVELOPMENT �,P No <br /> g ASSOCIATES,INC. o, 1-8-900-05 0 <br /> ri 7/26,2021 OKS ADDENDUM 4 r DRAWN BY: CHECKED BY: & M T C A 3 R D INTERIM ACTION LL <br /> sa�sm..�,�o sm�iwo ENGINEERS-CONSULTANTS Z <br /> o C. SMITH S. BARTKOSKE PROJECT <br /> MOT `"�'°`"�'°' '/2"202t °� AOD�DD�3 ELECTRICAL DETAILS <br /> No. MT-NT-2021-02.2 <br /> I a�l�� o R�13e:asoo (206)2435022 www.elcon.wm i /21/202 DI6 1411(D FOR BID iee� ti <br /> o P.O. BOX 538 aaEcr no.�smua /07/202 DKS FOR CITY REVIEW .1'ONA.L APPROVED BY: U <br /> N 16300 CHRISTENSEN ROAD,S1E 330 <br /> N EVERETT, WA 9820E 9EAITLE,WA 981 BB <br /> (425) 259-3164 No. DATE BY REVISION No. DATE BY REVISION b/18/21 SHEET N0. 120 OF 1 SO <br />