POWER LIGHTING ONE-LINE DIAGRAM ABBREVIATIONS DRAWING CONVENTIONS <br /> FOR RECEPTACLES IN THIS SECTION, WP DENOTES SEE LUMINAIRE SCHEDULE FOR FURTHER ALL DEVICES THIS SECTION TO BE 3 POLE LINO, A AMMETER, AMPERE M MAGNETIC COIL A TITLE <br /> WEATHERPROOF WHILE-IN-USE BOX AND GFI INFORMATION. RATINGS AS INDICATED. AC ABOVE COUNTER MCB MAIN CIRCUIT BREAKER DETAIL/SECTION TITLE UNDERLINE, <br /> AF AMPERE FRAME MCC MOTOR CONTROL CENTER o E1 SCALE: 1 4-1 -O" E1 = SHEET WHERE REFERENCED <br /> RECEPTACLE. FOR ALL OTHER DEVICES, WP TRANSFORMER, SECONDARY AFF ABOVE FINISHED FLOOR MH MANHOLE, METAL HALIDE / <br /> DENOTES NEMA 3R ENCLOSURE LINO. `� VOLTAGE. PHASE AND RATING AFG ABOVE FINISHED GRADE MIN MINIMUM <br /> CONVENIENCE RECEPTACLE - fb7 POLE MOUNTED LUMINAIRE 'Y1"'''` INDICATED AS APPUCABLE. AHJ AUTHORITY HAVING JURISDICTION MISC MISCELLANEOUS A A A = DETAIL/SECTION NUMBER <br /> DUPLEX LINO, MOUNTING HEIGHT WALL SWITCH, SYMBOL INDICATED AIC AMPERE INTERRUPTING CAPACITY MLO MAIN LUGS ONLY E2 E2 E2 = SHEET WHERE SHOWN <br /> �3 TO BE 18" AFF UNO WALL SWITCH LOCATION. SEE J_ GROUND AL ALUMINUM MOV METAL OXIDE VARISTOR <br /> 3 = CIRCUIT NUMBER LIGHTING CONTROL SCHEDULE - ANN ANNUNCIATOR MPZ COMBINATION TRANSFORMER AND <br /> CONVENIENCE RECEPTACLE - ° FOR WALL SWITCH TYPE AND FUSE ASYM ASYMMETRICAL PANELBOARD <br /> AT AMPERE TRIP MTD MOUNTED N NORTH ARROW <br /> FOURPLIX FEATURES. � 400 ATS AUTOMATIC TRANSFER SWITCH MTG MOUNTING <br /> SIMPLEX RECEPTACLE WITH ❑D REMOTE LED DRIVER �400— CIRCUIT BREAKER AUX AUXILIARY MTS MANUAL TRANSFER SWITCH <br /> ® BRASS FLOORPLATE AND SCREW BLDG BUILDING N NEUTRAL, NEW <br /> CAP © REMOTE 0-10V LIGHTING 3O NOTE <br /> —O� SWITCH BRKR BREAKER NO NORMALLY CLOSED <br /> CONTROLLER 400 C CONDUIT NEUT NEUTRAL <br /> ® DUPLEX RECEPTACLE - FLUSH Pc PHOTOCELL CONTACTOR RELAY M REVENUE GRADE METER AND CAN CABLE TELEVISION NO NORMALLY OPEN, NUMBER 0 REVISION REFERENCE <br /> MOUNTED IN FLOOR ENCLOSURE CB CIRCUIT BREAKER NIC NOT IN CONTRACT <br /> FOURPLEX RECEPTACLE - FLUSH CCTV CLOSED CIRCUIT TELEVISION NP NAMEPLATE EQUIPMENT ID TAG - <br /> ® CURRENT TRANSFORMER CDF CONTROLLED DENSITY FILL 0 PHASE, DIAMETER SEE EQUIPMENT SCHEDULE FOR <br /> MOUNTED IN FLOOR III CKT CIRCUIT P PANEL, POLE XXX FURTHER INFORMATION, <br /> QJ JUNCTION BOX a p It CENTER LINE PB PUSH-BUTTON = COORDINATE EQUIPMENT LOCATION <br /> d TRANSFER SWITCH CL CURRENT LIMITING PF POWER FACTOR WITH ASSOCIATED MECHANICAL, <br /> SPECIAL PURPOSE RECEPTACLE, CLF CURRENT LIMITING FUSE PH PHASE CIVIL, ETC. PLANS <br /> DESIGNATION AND AMPERAGE AS MOTOR CONNECTION CLR CLEAR PIR PASSIVE INFRARED <br /> ®.A= INDICATED, OR SHOWN IN CM CIRCULAR MILS PIV POST INDICATOR VALVE <br /> SCHEDULE, SEE SPECIFICATIONS FEEDER TAG - SEE FEEDER COMM COMMUNICATIONS PNL PANEL <br /> CONNECTION POINT TO XX SCHEDULE FOR FURTHER CONC CONCRETE POMB POSITION ORIENTED MOGUL BASE <br /> EQUIPMENT SPECIFIED FURNISHED INFORMATION CONST CONSTRUCTION (SOCKET) GENERAL NOTES <br /> AND INSTALLED BY OTHER CENT CONTINUED PS PRESSURE SWITCH <br /> ® CPT CONTROL POWER TRANSFORMER PUD SNOHOMISH PUD <br /> TRADES. RACEWAY, CONDUCTOR OR CONTROL RELAY R RELAY 1. MEET ALL REQUIREMENTS OF THE NEC AND AHJ FOR <br /> AND CONNECTION BY ELECTRICAL CT CURRENT TRANSFORMER REC RECEPTACLE(S), RECESSED INSTALLATION AND CONSTRUCTION. <br /> CONTRACTOR. CONDUIT AND RACEWAY CTRL CONTROL RM ROOM 2. VERIFY LOCATION OF ALL LIFT STATION AND TREATMENT <br /> NONFUSED DISCONNECT SWITCH. CU COPPER SCH SCHEDULE EQUIPMENT WITH CIVIL CONTRACTOR PRIOR TO ROUGH-IN. <br /> Lam' SIZE 30A UNLESS INDICATED ALL CONDUCTORS INCLUDING NEUTRAL AND DOC DEDICATED DIALER CIRCUIT SO SMOKE DETECTOR COORDINATE EXACT CIRCUIT BREAKER, FUSE AND WIRE SIZE <br /> OTHERWISE, 3 POLE UNO GROUND SHALL BE SIZED TO MATCH OR EXCEED OEM DEMAND SF SQUARE FEET WITH CIVIL PRIOR TO ROUGH-IN. <br /> OVERCURRENT PROTECTION DEVICE PER NEC, 2#12, DEMO DEMOLITION SHT SHEET 3. ALL EXTERIOR DEVICES TO BE CIRCUITED WITH #10 WIRE <br /> FUSED DISCONNECT SWITCH. DIM DIMENSION SNOPUD SNOHOMISH PUD <br /> SIZE INDICATED, (60 = SWITCH 1#12G MINIMUM UNO. ALL CONDUITS SHALL BE DISC DISCONNECT SPD SURGE PROTECTIVE DEVICE MINIMUM UNLESS NOTED OTHERWISE. <br /> Ip SIZED TO MATCH OR EXCEED QUANTITIES AND ON DOWN SUPV SUPERVISOR 60/40 RATING, 40 = FUSE RATING) 3 SIZES OF CONDUCTORS PER NEC, 3/4- MINIMUM <br /> POLE LINO LINO. DS DISCONNECT SWITCH SW SWITCH 4. ALL WIRING SHALL BE COPPER UNLESS NOTED OTHERWISE. <br /> DWG DRAWING SWBD SWITCHBOARD 5. VERIFY LOCATIONS OF OTHER UTILITIES PRIOR TO <br /> COMBINATION MOTOR STARTER HOME RUN, DESTINATION DZ DAYLIGHT ZONE SWGR SWITCHGEAR COMMENCING WORK, PROVIDE REQUIRED CLEARANCES FROM <br /> AND DISCONNECT, SIZE PER SHOWN, CIRCUIT NUMBERS E EMPTY, EXISTING SYM SYMMETRICAL OTHER UTILITIES, BUILDINGS, AND FREESTANDING <br /> P1-1,3 PRECEDED BY PANEL NAME, <br /> MANUFACTURER REQUIREMENTS, EF EXHAUST FAN T THERMOSTAT STRUCTURES, DURING INSTALLATION OF CONDUITS, CABLES, <br /> NUMBER OF POLES AS REQUIRED SEE PANEL SCHEDULE, ARROW ELEC ELECTRICAL TB TERMINAL BLOCK, TRANSFORMER BANK ETC. <br /> DOES NOT ALWAYS POINT TO ELEV ELEVATION, ELEVATOR TEL TELEPHONE <br /> PANEL. EMT ELECTRICAL METALLIC TUBING 6. USE ELECTRICAL PLANS FOR DETERMINING LUMINAIRE AND <br /> PANEL TTB TELEPHONE TERMINAL BOARD DEVICE COUNTS. QUANTITIES SHOWN WITHIN CALCULATION <br /> �T EXIST EXISTING TYP TYPICAL TRANSFORMER IJ ,FU FUSE UG UNDERGROUND CONDUIT WITH MEDIUM F AND CONTROL SCHEDULES SHALL NOT BE USED FOR BID <br /> VOLTAGE CONDUCTORS COUNTS. <br /> FACP FIRE ALARM CONTROL PANEL UH UNIT HEATER <br /> ❑H HANDHOLE, SIZE AS NOTED FBOIC FURNISHED BY OTHERS INSTALLED BY UL UNDERWRITERS LABORATORIES 7. NOT ALL COMPONENTS OF THE ELECTRICAL SYSTEMS ARE <br /> CONDUIT WITH LINE VOLTAGE SHOWN (FOR CLARITY). PROVIDE MATERIALS AND LABOR <br /> T THERMOSTAT a CONDUCTORS CONTRACTOR LINO UNLESS NOTED OTHERWISE <br /> O FLUOR FLUORESCENT UPS UNINTERRUPTIBLE POWER SUPPLY NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM. <br /> GROUND ROD CONDUIT WITH LOW VOLTAGE FSA FIRE SYSTEM ANNUNCIATOR V VOLTMETER, VOLT <br /> T FT FOOT VA VOLT AMPERE(S) 8. THE AC OF THE PANELS SHOWN ARE TENTATIVE AND GIVEN <br /> CONDUCTORS FB FLUIDIZED THERMAL BACKFILL FOR BIDDING PURPOSES ONLY. CONTRACTOR SHALL <br /> © GENERATOR VP VAPORPROOF <br /> J CONDUIT DOWN FVNR FULL VOLTAGE NON-REVERSING W WIRE, WATT CALCULATE THE PANEL AIC BASED UPON FINAL CONDUIT <br /> GROUND TEST WELL G,GND GROUND W/ WITH ROUTING AND TRANSFORMERS AND FUSES SUBMITTED. <br /> CONDUIT UP GA GAUGE WAC WASHINGTON ADMINISTRATIVE CODE <br /> GALV GALVANIZED 9. PROVIDE ALL SNOHOMISH COUNTY PUD (SNOPUD) VAULTS <br /> CONDUIT STUBBED AND GA GROUND FAULT CIRCUIT INTERRUPTER WHD WATTHOUR DEMAND METER PER SNOPUD STANDARDS, SEE SHEET E6.7 FOR FURTHER <br /> CAPPED AS SHOWN GFP EQUIPMENT GROUND FAULT PROTECTION W/o WITHOUT INFORMATION. <br /> GRC,GRS GALVANIZED RIGID STEEL WP WEATHERPROOF <br /> WSEC WASHINGTON STATE ENERGY CODE 10. SEE SHEET C4.17 FOR PRECAST VAULT BEDDING DETAILS <br /> CONDUIT CONTINUED HH HANDHOLE XFMR TRANSFORMER AND SUBGRADE PREPARATION. ALL PRECAST VAULTS <br /> HP HORSEPOWER SUBJECTED TO TERMINAL LOADS SHALL BE CONTRACTOR <br /> EXPOSED FLEX CONDUIT HIPS HIGH PRESSURE SODIUM 3P 3-POLE DESIGNED TO MEET THE UNDERGROUND UTILITY STRUCTURE <br /> HVAC HEATING, VENTILATION, AIR CONDITIONING LOADING CRITERIA SHOWN ON SHEET G1.3. SEE <br /> HWH HOT WATER HEATER SPECIFICATIONS FOR FURTHER DETAILS. <br /> IC INTERRUPTING CAPACITY <br /> JB,J-BOX JUNCTION BOX 11. PROVIDE INTEGRAL LOCKS OR PADLOCK EYES FOR ALL <br /> _ K KELVIN ENCLOSURE DOORS. PROVIDE LOCKABLE HANDLES FOR ALL <br /> KCM THOUSAND CIRCULAR MILS DISCONNECTS. <br /> KV KILOVOLT 12. PROVIDE NEMA 4X STAINLESS STEEL HOUSINGS FOR ALL <br /> E KVA KILOVOLT AMPERE(S) SWITCHBOARDS, PANELBOARDS, TRANSFORMERS, <br /> a / KW KILOWATT(S) DISCONNECTS, COMMUNICATIONS CABINETS AND COMBINATION <br /> o s LC LIGHTING CONTACTOR TRANSFORMER-PAN ELBOARDS UNLESS NOTED OTHERWISE. <br /> LED LIGHT EMITTING DIODE <br /> N / IF SHEET IS LESS THAN 22x34 <br /> Know whaYs be I,I.I <br /> N REDUCE SCALE ACCORDINGLY U) <br /> low. <br /> Call before you dig. 0 <br /> a <br /> m PD. SI ENGINEER SCALE PORT OF EVERETT DWG. NO. EO 1 W <br /> EICO N ^ X.S� ES SIATERLIS NONE <br /> Porto . a DESIGNED BY DATE <br /> � .� `�`°Ao�. NORTON TERMINAL DEVELOPMENT CIP N0. <br /> i ljY'�'� c � N D. SIATERLIS 05/07/20Z1 <br /> o ♦♦♦\\++ �i ASSOCIATES INC. - O <br /> o 1-a—soo—os <br /> DRAWN BY: CHECKED BY: & M T C A 3 R D INTERIM ACTION LL <br /> rn aca�sme�,�ewro.voo ENGINEERS—CONSULTANTS <br /> o s.mew n vun o C. SMITH S. BARTKOSKE PROJECT <br /> EVERMuaal 3azasw Fu l�osl xansao (206)243-5022 ww Acon.com 6 21 202 DIGS ISSUE)FOR BID tDT� 1 N0. <br /> P.O. BOX 538 „ En„o.,N F.( 16300 CHRISTENSEN ROAD,STE 330 g �07�202 OKS FOR CRY RENEW 9�O1VAL APPROVED BY: ELECTRICAL LEGEND MT-NT-2021-02.2 Q <br /> EVERE0 (425) 2 WA 98206 SEATTLE,WA 98188 & ABBREVIATIONS SHEET N0. 103 OF 150 <br /> (425) 259-3164 N0. DATE BY REVISION N0. DATE Bi REVISION <br />