Laserfiche WebLink
3EEONOTE EX A4 <br /> (DECOMMISSIONED)PH PATH, PORT GARDNER BAY <br /> EAST WATERWAY <br /> \�\ 2j,. "'"• �.,��•�\ CLEAR&GRUB AREA WEST OF EX JERSEY <br /> BARRIER TO EX SHORELINE ROCKERY. <br /> G ;\'• \\ REMOVE AND DISPOSE OF TOP 6"OF SOIL <br /> AND REPL W/4"STREAMBED COBBLES <br /> �\ „l.�•. :• \\\\ EX CONC BASE/ <br /> �7) �,• ., �� TRANSMISSION POLE, PIP <br /> EX CONC STEPS, �•' �'' "�• _\ DEMO EX POWER EQUIPMENT <br /> EMO EX <br /> PIP,TYP(6) \\\ ".., . ;�'• •'•"'� \\ 3EE PHOTORI2 <br /> 1 _ — <br /> DEMO EX CB, <br /> SEE NOTE 1 &5 CUT,CAP&ABAN ' "'. ,. .'•• .. .. ,. :"- '•__ <br /> EX 10°SD PIPE, EX JERSEY •, .^ c'.• oP �%;\. •-L'•'• <br /> EX 6' HIGH CSBC RIM=14.88 "`o�"P� o' '�: ,.•a,• �. <br /> SEE DETAIL X ON SHT XX BARRIER, PIP 'p'• •�'•, �•t �\ <br /> PRE-LOAD AREA IE=13.1 (10"E) 6' -; •• •••��••.:. • V`\.,;'�. \11 <br /> -� EX MONITORING 17 �•... •, ?.• 1 <br /> IE=13.1 (10"N) �LL�IP,TYP <br /> \ EX ASPH ROAD <br /> DEMO EX MH, s DEMO EX <br /> so EX EDP <br /> j GVL PATH <br /> SEE NOTE 1 &/5 » ` <br /> v. <br /> RIM-15.38 x x x 16 12 i :•.•+ �• .•. - <br /> �. IE 11.5(10" EX MONITORING <br /> --� ` ( ( '��,t•.. w•;\� '._'v:• WELL PIP,TYP. <br /> \ FILL EX 10"SD w/CDF `-J SEE NOTE 8 <br /> \ &ABANDON-IN-PLACE r x\ \ EX BERM <br /> \ \ ?" �••.` END OF CLEAR <br /> I )) EX PUD SUBSTATION /� SUBSTATION �' <br /> I \ "J ••FENCE,PIP .:• &GRUB AREA <br /> o r / � ,;r r � \ 'b7 <br /> DEMO EX MH, " /-/ l \?4- �'•%�' \~ <br /> SEE NOTE 1 &5 (/ .:^;.' +. .�,. \\\\\ EX ROCK <br /> BULKHEAD <br /> \ RIM=15.81 x / ^ / \ �� I \ \ ..:, L 6 l 1 BU D <br /> x-C_�x x / / R(TPER �- ` . <br /> LINE <br /> DEVOLMON NOTES DEMOLMON DETAIL LEGEND <br /> = <br /> 1. THE EXISTING UTILITY LOCATIONS AND DEPTHS SHOWN ON D 1.1 D 1.6 SCALE: 1" 30' DEMO EX ASPHALT <br /> THESE PLANS ARE APPROXIMATE. NO REPRESENTATION IS MADE 5. CONTRACTOR SHALL DEMO EXISTING CB AND MH STTRUCTURES <br /> '" E`AS TO THE ACCURACY OR COMPLETENESS OF THE TO ELEVATION 14' OR LOWER. FILL REMAINING STRUCTURES •;rr,',!,�� DEMO EX GRAVEL <br /> INFORMATION. THE CONTRACTOR SHALL POTHOLE OR OTHERWISE AND PIPE WITH CDF. PLACE GEOGRID OVER EXISTING SD CLEAR & GRUB AREA <br /> CONFIRM EXISTING CONDITIONS PRIOR TO START OF WORK. IF STRUCTURES BEFORE BACKFILL PLACEMENT AND COMPACTION. UPSTREAM MH EX GRADE DOWNSTREAM MH <br /> CONDITIONS DIFFER FROM THOSE SHOWN ON THE PLANS, THE EXTEND GEOGRID 3' MIN ON ALL SIDES EXCEPT EXTEND TO <br /> CONTRACTOR SHALL NOTIFY THE ENGINEER AND SHALL NOT EXISTING FENCE ON NORTH SIDE. SEE SHEET C3.21. SAWCUT LINE <br /> BEGIN CONSTRUCTION UNTIL THE CHANGED CONDITIONS HAVE CONTRACTOR SHALL USE CARE TO PROTECT THE ADJACENT \/�\��\ ° <br /> BEEN EVALUATED. THE CONTRACTOR SHALL TAKE SNOHOMISH PUD FENCE, BUILDING AND EQUIPMENT FROM �^ ��'���������..........�������� \�j�\�j�\�j�\�j�\�j�\�j�\�j�\� /���j���j���j���j XX LOCATION & DIRECTION OF PHOTO. SEE <br /> PRECAUTIONARY MEASURES TO PROTECT FROM DAMAGE OR DAMAGE. DAMAGE TO PUD INFRASTRUCTURE BY THE SHEETS D3.1 TO D3.3 <br /> DESTRUCTION ALL UTILITIES AS SHOWN AND ALL UTILITIES NOT CONTRACTOR SHALL BE REPAIRED AT NO COST TO THE PORT <br /> SHOWN THAT MAY BE ENCOUNTERED DURING CONSTRUCTION TO THE SATISFACTION OF THE PUD. a EXISTING MONITORING WELL, <br /> DUE TO NO RECORD OF THEIR EXISTENCE. °Q 5X PIPE DIA MIN 5X PIPE DIA MIN ° PROTECT—IN—PLACE, SEE NOTE 6 <br /> 6. CLEARING, GRUBBING & DEMOLITION ACTIVITIES SHALL NOT <br /> 2. UTILITIES, STRUCTURES AND SITE FEATURES NOT INDICATED FOR DISTURB AN AREA WITHIN ABOUT 1' AROUND PERIMETER OF <br /> DEMOLITION SHALL BE PROTECTED—IN—PLACE. EXISTING MONITORING WELLS TO PROTECT THE WELLS IN PLACE. a <br /> BRUSH AND WEEDS TALLER THAN 12 INCHES THAT ARE <br /> 3. ALL ITEMS MARKED FOR DEMOLITION (DEMO) SHALL BE LOCATED WITHIN THE 1' OF UNDISTURBED AREA AROUND EACH <br /> DEMOLISHED AND REMOVED FROM THE SITE AND DISPOSED OF MONITORING WELL SHALL BE REMOVED BY HAND WITH SHOVEL. q <br /> AT AN APPROVED UPLAND DISPOSAL SITE IN ACCORDANCE WITH VEGETATION REMOVAL SHALL INCLUDE REMOVAL OF ROOTS. ° ° a 4 <br /> THE SPECIFICATIONS. ANY FEES REQUIRED FOR DISPOSAL ARE ad a CALL48HOURS <br /> THE RESPONSIBILITY OF THE CONTRACTOR. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR REVIEW OF THE BEF0REY0UDIG <br /> EXISTING SHORELINE CONDITIONS AND SHALL CHOOSE THE NON—EX PIPE SHRINK SHRINK G OUT FILL EX PIPE GROUT EX CDF PLUG, TYP DIAL811 <br /> 4. EXISTING ASPHALT PATH IS APPROXIMATELY 4" THICK. APPROPRIATE EQUIPMENT TO CLEAR, GRUB AND PLACES KEY N 0 T E S <br /> CONTRACTOR SHALL FIELD VERIFY THICKNESS AND REMOVE THE STREAMBED COBBLES SO AS TO NOT DAMAGE OR TRIGGER10 <br /> FULL THICKNESS OF ACE MARKED FOR DEMO. FAILURE OF THE SHORELINE ROCKERY. DAMAGE TO THE <br /> ROCKERY CAUSED BY THE CONTRACTOR SHALL BE REPAIRED iO EXPOSE AND BREECH EXISTING PIPE 5. PIPE DIAMETERS VERT DATUM: NAVD 88 <br /> BY THE CONTRACTOR AT NO COST TO THE PORT, TO THE FROM UPSTREAM AND DOWNSTREAM MANHOLES. IF PIPE PLUG CONV TO MLLW = NAVD88+2.03 <br /> PORT'S SATISFACTION. 2 GRAVITY PIPE ABANDON-IN-PLACE DETAIL IS ENCOUNTERED, EXPOSE AND BREECH PIPE AN ADDITIONAL HORZ DATUM: NAD 83/91 <br /> 2 PIPE DIAMETERS FURTHER FROM STRUCTURE UNTIL AN IF SHEET IS LESS THAN 22x34 W <br /> C.X.X CX.X SCALE: NTS UNOBSTRUCTED SECTION OF PIPE IS BREECHED EACH END. REDUCE SCALE ACCORDINGLY > <br /> PROJECT ENGINEER: SCALE: PORT OF EVERETT W <br /> DWG. N0. D W <br /> 4A�p4'dsa�9A N. WATSON AS SHOWN . <br /> 5�16 , NpoJO DESIGNED BY: DATE: <br /> Port of �g _ >� J. BECKER 06/21/2021 NORTON TERMINAL DEVELOPMENT CIP No. H <br /> T)^ 7�M & MTCA 3RD INTERIM ACTION 1-8-900-05 V <br /> EVERETT DRAWN BY CHECKED S <br /> L L 16015th Avenue,Suite 1300 sroia a K. EDWARDS, D. YU N. WATSON PROJECT <br /> P.O. BOX 538 Seattle,Washington 98101 �� eel � DEMOLITION DETAILS NO. MT—NT-2021-02.2 <br /> EVERETT, WA 98206 ® 06/21/2021 NW NEW SHEET 97oNaL � b�' APPROVED BY: C O <br /> (425) 259-3164 (206)382-061 Fax(206)382-0500 (3 0 r 4) SHEET NO. 1 6 OF 1 49 LL <br /> PROJECT NO.1600120 N0. DATE BY REVISION N0. DATE BY REVISION <br />