My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1717 13TH ST 2024 MEDICAL CENTER Plans 2025-09-29
>
Address Records
>
13TH ST
>
1717
>
MEDICAL CENTER
>
Plans
>
1717 13TH ST 2024 MEDICAL CENTER Plans 2025-09-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2025 1:17:05 PM
Creation date
9/29/2025 1:11:36 PM
Metadata
Fields
Template:
Address Document
Street Name
13TH ST
Street Number
1717
Tenant Name
MEDICAL CENTER
Permit
E2408-072
Year
2024
Notes
Replacement of PET CT Machine
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 2 1 3 1 4 1 5 1 6 1 7 18 9 10 1 11 <br /> GENERAL NOTES: <br /> 1. NEW RECEPTACLES SHALL BE HOSPITAL GRADE,ALL EMERGENCY RECEPTACLES AND <br /> 5.15.2 \6 / n COVER PLATES SHALL BE RED WITH CIRCUITING LABEL INDICATING PANEL AND CIRCUIT NUMBER. tg b architects <br /> 2. MAINTAIN EXISTING SYSTEMS NOT IDENTIFIED FOR DEMOLITION.MAINTAINING EXISTING <br /> SYSTEMS INCLUDES RELOCATING THE SYSTEMS TO COORDINATE WITH WORK OF THIS <br /> CONTRACT,WHEN WORK OF THIS CONTRACT CANNOT BE DONE WHILE THE EXISTING <br /> SYSTEM IS IN ITS PRESENT LOCATION. t 425.778.1530 21911 76th Ave W.Ste 210 <br /> 3. ANY EXISTING WIRING SERNNG DEVICES TO REMAIN IN SERVICE AND WHICH MAY BE f 425.774.7803 Edmonds WA 98026 <br /> C.2 AFFECTED BY WORK PERFORMED UNDER THIS CONTRACT SHALL BE REROUTED TO info@tgbarchitecls.com <br /> D2NL3-32 ® Q D2NL3-30 MAINTAIN CIRCUIT CONTINUITY.CONTRACTOR SHALL ASSUME THE RISK OF MAINTAINING www.tgbarchitects.com <br /> EXISTING SYSTEMS,EXCEPT RELOCATION OF#2 AWG AND ABOVE SHALL BE CONSIDERED <br /> D2NL2-30 AN ADDITIONAL COST IF NOT SHOWN TO BE RELOCATED.IF SUCH WIRING IS FOUND THE <br /> ____ <br /> D2N 2-30 1 CD CONTRACTOR SHALL NOTIFY ARCHITECT OF WIRING LOCATION,REASON IT MUST BE <br /> G I D2NL2-30 MOVED AND COST OF RELOCATION AND RECEIVE THE OWNER'S APPROVAL BEFORE <br /> I Q1 PROCEEDING WITH THE WORK. <br /> HQLp.2_______I HOLD HOT <br /> INJECT-GURNEY INJECT GURNEYLABo 4. EXAMINE DRAWINGS OF ALL DISCIPLINES TO DETERMINE WHERE WORK OF OTHER TRADES <br /> zoo.os oo lz WILL OR IS LIKELY TO REQUIRE RELOCATION OF EXISTING SYSTEMS.REMOVE AND <br /> RELOCATE ELECTRICAL EQUIPMENT IN THE WAY OF WORK OF OTHER TRADES.EXACT <br /> RELOCATION REQUIREMENT OF EXISTING SYSTEMS TO REMAIN TO BE BASED ON DETAILED EVIDENCE <br /> D2NL2-30 COORDINATION WITH OTHER TRADES.CONTRACTOR TO PROVIDE PROPOSED LOCATIONS OF <br /> D2NL4-5� r%=1q: RELOCATED DEVICES TO OWNER FOR APPROVAL PRIOR TO COMMENCEMENT OF WORK. BASED <br /> L3-34 <br /> �WD ® ® O D2NL2-20 Dz DESIGN <br /> 5. RELOCATION OF ANY SYSTEM SHALL BE PERMANENT. DI SERVICES .....Da.,.,..,.,a <br /> 6 ` 6. REROUTE EXISTING CIRCUITS THAT ARE AFFECTED AS A RESULT OF THIS CONTRACT THAT <br /> I+30" SERVE DEVICES TO REMAIN IN SERVICE. <br /> NI -17 D2NL 21 <br /> ' FLAG NOTES: <br /> DEMOLISH EXISTING RECEPTACLE.PULL BACK EXISTING BRANCH CIRCUIT AND MAINTAIN <br /> FOR RECONNECTION. REFER TO FLAG NOTE 1 ON SHEET E1.21-PET FOR RECONNECTION <br /> ® D2NL3-32 RR-U-ADA s PPLv LEAN SOIL D HOLD REQUIREMENTS. <br /> zoo.lo 200.11 a.o7 © REMOVE EXISTING NURSE CALL DEVICE AND MAINTAIN EXISTING CIRCUIT. REFER TO FLAG <br /> NOTE 2 ON SHEET E1.21-PET FOR NEW LOCATION OF DEVICE AND RECONNECTION <br /> REQUIREMENTS. <br /> D2 L3-32 D2NL2-20 © REMOVE EXISTING LIGHT FIXTURE AND MAINTAIN FOR RELOCATION. PULL BACK BRANCH y <br /> G W CIRCUIT AND MAINTAIN FOR RECONNECTION.REFER TO FLAG NOTE 5 ON SHEET <br /> E1.21—PET FOR NEW FIXTURE LOCATION AND RECONNECTION REQUIREMENTS. <br /> 57724�,cp <br /> PETICT ® DISCONNECT AND PULL BACK EXISTING LIGHTING BRANCH CIRCUIT AND MAINTAIN FOR IST65`" <br /> z z O RECONNECTION.REFER TO FLAG NOTE 6 ON SHEET E1.21—PET FOR RECONNECTION ZONAL ' <br /> ® CORRIDOR REQUIREMENTS. wloelz92a <br /> D2NL4-15 200.05 <br /> +48'• © DISCONNECT EXISTING DATA OUTLET AND MAINTAIN FOR RECONNECTION.REFER TO FLAG <br /> NOTE 3 ON SHEET E1.21—PET FOR RECONNECTION REQUIREMENTS. <br /> DN © DISCONNECT AND REMOVE EXISTING ENCLOSED CIRCUIT BREAKER AND MAINTAIN <br /> $D2NL4-13 HOLD FEEDERS.REFER TO FLAG NOTE 4 ON SHEET E1.21—PET FOR RECONNECTION <br /> INJECT-GURNEY REQUIREMENTS. <br /> D2NL4-11 200.13 OFFICE CANCER <br /> 0 TR O � DISCONNECT EXISTING X—RAY ON LIGHT AND MAINTAIN FOR RECONNECTION. REFER TO <br /> UP FLAG NOTE 7 ON SHEET E1.21—PET FOR RECONNECTION REQUIREMENTS. <br /> D2NL4-9 (� <br /> a 6° (c'' <br /> RR-U-ADA <br /> +45" 2® �D2NL4-7 <br /> "D2NL2-20 +36" CONON®L O <br /> 4© <br /> _ D2NL2-26 <br /> D.6 ® D.6 <br /> LEVEL 2 - ENLARGED PET CT POWER AND SYSTEMS DEMOLITION PLAN 0 2' 4' 8' <br /> SCALE:1/4" = l'—O" E1.00—PE7 N 1" PLOTTED PROVIDENCE <br /> COLBY PET CT <br /> 1717 13th St <br /> Everett,WA 98201 <br /> 5.15.2 l l l <br /> CONSTRUCTION <br /> DOCUMENTS <br /> UEEEE <br /> c:2 <br /> D3NL5-6a D3NL5-6a D3NL5-8b ® _ <br /> O O O D2NH1-7b,c I D2tJH1-76,c I D2NH1-7 <br /> HQLjI,z <br /> m i I 4 LEVEL 2 - PET CT <br /> __ I D2 H1-7 Hor <br /> NJE°0006 NE 2-1 "EY ELECTRICAL <br /> 3NL5-6a 3 L 6 D3NL5-86 a D2NH1-7a <br /> a <br /> DEMOLITION PLANS <br /> r�'o® ISSUANCE <br /> OD2NH1-7 D3EH1-2 D2NH1-5 D EH No. Description Dab <br /> PERMIT SET 07/0912074 <br /> D3NL5-6a ❑ ❑ <br /> LL���JII o <br /> D3NL5-8b <br /> ICI D3EH1-2 <br /> D3EH1-4c u�u. <br /> R-U-ADA 5 N SOIL D HOLD <br /> D3NL5-6a D3NL5-8b z 1 z 11 7 <br /> O 0 D2NH1-5 <br /> c <br /> b <br /> a <br /> PETIT D3NL5-8b <br /> 00 oz O O <br /> LE) D3NL5-86 CORRIDOR <br /> m <br /> D3EH1-2 <br /> DN g =� <br /> a HOLD 1 <br /> 13 INJECT-OUR NEv <br /> F2NH1-7 200.13 OFFICE CANCER <br /> O CTR DID <br /> ❑D Dols <br /> UP ❑ it IT, <br /> RRR® ❑ D3EHI-2 <br /> D _ D3EH1— CONTROL D3EH1-4 <br /> 200 04 PROJECT INFORMATION <br /> WAITING PROJECT NUMBER: B24-1032 <br /> gala <br /> PROJECT LEAD: JGG <br /> a DRAWN BY: CMB <br /> D.6 D.6 <br /> LEVEL 2- ENLARGED PET CT LIGHTING DEMOLITION PLAN e 0 2' 4' 8' SHEET NO <br /> Ei.t1 SCALE:1/4" = l'—O" E1.00—PET N 1" PLOTTED I NEIIII E 1 .11 -PET <br /> 1 2 3 4 5 6 7 6 9 10 11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.