Laserfiche WebLink
1 2 1 3 1 4 1 5 1 6 1 7 18 9 10 1 11 <br /> GENERAL NOTES: <br /> 1. NEW RECEPTACLES SHALL BE HOSPITAL GRADE,ALL EMERGENCY RECEPTACLES AND <br /> 5.15.2 \6 / n COVER PLATES SHALL BE RED WITH CIRCUITING LABEL INDICATING PANEL AND CIRCUIT NUMBER. tg b architects <br /> 2. MAINTAIN EXISTING SYSTEMS NOT IDENTIFIED FOR DEMOLITION.MAINTAINING EXISTING <br /> SYSTEMS INCLUDES RELOCATING THE SYSTEMS TO COORDINATE WITH WORK OF THIS <br /> CONTRACT,WHEN WORK OF THIS CONTRACT CANNOT BE DONE WHILE THE EXISTING <br /> SYSTEM IS IN ITS PRESENT LOCATION. t 425.778.1530 21911 76th Ave W.Ste 210 <br /> 3. ANY EXISTING WIRING SERNNG DEVICES TO REMAIN IN SERVICE AND WHICH MAY BE f 425.774.7803 Edmonds WA 98026 <br /> C.2 AFFECTED BY WORK PERFORMED UNDER THIS CONTRACT SHALL BE REROUTED TO info@tgbarchitecls.com <br /> D2NL3-32 ® Q D2NL3-30 MAINTAIN CIRCUIT CONTINUITY.CONTRACTOR SHALL ASSUME THE RISK OF MAINTAINING www.tgbarchitects.com <br /> EXISTING SYSTEMS,EXCEPT RELOCATION OF#2 AWG AND ABOVE SHALL BE CONSIDERED <br /> D2NL2-30 AN ADDITIONAL COST IF NOT SHOWN TO BE RELOCATED.IF SUCH WIRING IS FOUND THE <br /> ____ <br /> D2N 2-30 1 CD CONTRACTOR SHALL NOTIFY ARCHITECT OF WIRING LOCATION,REASON IT MUST BE <br /> G I D2NL2-30 MOVED AND COST OF RELOCATION AND RECEIVE THE OWNER'S APPROVAL BEFORE <br /> I Q1 PROCEEDING WITH THE WORK. <br /> HQLp.2_______I HOLD HOT <br /> INJECT-GURNEY INJECT GURNEYLABo 4. EXAMINE DRAWINGS OF ALL DISCIPLINES TO DETERMINE WHERE WORK OF OTHER TRADES <br /> zoo.os oo lz WILL OR IS LIKELY TO REQUIRE RELOCATION OF EXISTING SYSTEMS.REMOVE AND <br /> RELOCATE ELECTRICAL EQUIPMENT IN THE WAY OF WORK OF OTHER TRADES.EXACT <br /> RELOCATION REQUIREMENT OF EXISTING SYSTEMS TO REMAIN TO BE BASED ON DETAILED EVIDENCE <br /> D2NL2-30 COORDINATION WITH OTHER TRADES.CONTRACTOR TO PROVIDE PROPOSED LOCATIONS OF <br /> D2NL4-5� r%=1q: RELOCATED DEVICES TO OWNER FOR APPROVAL PRIOR TO COMMENCEMENT OF WORK. BASED <br /> L3-34 <br /> �WD ® ® O D2NL2-20 Dz DESIGN <br /> 5. RELOCATION OF ANY SYSTEM SHALL BE PERMANENT. DI SERVICES .....Da.,.,..,.,a <br /> 6 ` 6. REROUTE EXISTING CIRCUITS THAT ARE AFFECTED AS A RESULT OF THIS CONTRACT THAT <br /> I+30" SERVE DEVICES TO REMAIN IN SERVICE. <br /> NI -17 D2NL 21 <br /> ' FLAG NOTES: <br /> DEMOLISH EXISTING RECEPTACLE.PULL BACK EXISTING BRANCH CIRCUIT AND MAINTAIN <br /> FOR RECONNECTION. REFER TO FLAG NOTE 1 ON SHEET E1.21-PET FOR RECONNECTION <br /> ® D2NL3-32 RR-U-ADA s PPLv LEAN SOIL D HOLD REQUIREMENTS. <br /> zoo.lo 200.11 a.o7 © REMOVE EXISTING NURSE CALL DEVICE AND MAINTAIN EXISTING CIRCUIT. REFER TO FLAG <br /> NOTE 2 ON SHEET E1.21-PET FOR NEW LOCATION OF DEVICE AND RECONNECTION <br /> REQUIREMENTS. <br /> D2 L3-32 D2NL2-20 © REMOVE EXISTING LIGHT FIXTURE AND MAINTAIN FOR RELOCATION. PULL BACK BRANCH y <br /> G W CIRCUIT AND MAINTAIN FOR RECONNECTION.REFER TO FLAG NOTE 5 ON SHEET <br /> E1.21—PET FOR NEW FIXTURE LOCATION AND RECONNECTION REQUIREMENTS. <br /> 57724�,cp <br /> PETICT ® DISCONNECT AND PULL BACK EXISTING LIGHTING BRANCH CIRCUIT AND MAINTAIN FOR IST65`" <br /> z z O RECONNECTION.REFER TO FLAG NOTE 6 ON SHEET E1.21—PET FOR RECONNECTION ZONAL ' <br /> ® CORRIDOR REQUIREMENTS. wloelz92a <br /> D2NL4-15 200.05 <br /> +48'• © DISCONNECT EXISTING DATA OUTLET AND MAINTAIN FOR RECONNECTION.REFER TO FLAG <br /> NOTE 3 ON SHEET E1.21—PET FOR RECONNECTION REQUIREMENTS. <br /> DN © DISCONNECT AND REMOVE EXISTING ENCLOSED CIRCUIT BREAKER AND MAINTAIN <br /> $D2NL4-13 HOLD FEEDERS.REFER TO FLAG NOTE 4 ON SHEET E1.21—PET FOR RECONNECTION <br /> INJECT-GURNEY REQUIREMENTS. <br /> D2NL4-11 200.13 OFFICE CANCER <br /> 0 TR O � DISCONNECT EXISTING X—RAY ON LIGHT AND MAINTAIN FOR RECONNECTION. REFER TO <br /> UP FLAG NOTE 7 ON SHEET E1.21—PET FOR RECONNECTION REQUIREMENTS. <br /> D2NL4-9 (� <br /> a 6° (c'' <br /> RR-U-ADA <br /> +45" 2® �D2NL4-7 <br /> "D2NL2-20 +36" CONON®L O <br /> 4© <br /> _ D2NL2-26 <br /> D.6 ® D.6 <br /> LEVEL 2 - ENLARGED PET CT POWER AND SYSTEMS DEMOLITION PLAN 0 2' 4' 8' <br /> SCALE:1/4" = l'—O" E1.00—PE7 N 1" PLOTTED PROVIDENCE <br /> COLBY PET CT <br /> 1717 13th St <br /> Everett,WA 98201 <br /> 5.15.2 l l l <br /> CONSTRUCTION <br /> DOCUMENTS <br /> UEEEE <br /> c:2 <br /> D3NL5-6a D3NL5-6a D3NL5-8b ® _ <br /> O O O D2NH1-7b,c I D2tJH1-76,c I D2NH1-7 <br /> HQLjI,z <br /> m i I 4 LEVEL 2 - PET CT <br /> __ I D2 H1-7 Hor <br /> NJE°0006 NE 2-1 "EY ELECTRICAL <br /> 3NL5-6a 3 L 6 D3NL5-86 a D2NH1-7a <br /> a <br /> DEMOLITION PLANS <br /> r�'o® ISSUANCE <br /> OD2NH1-7 D3EH1-2 D2NH1-5 D EH No. Description Dab <br /> PERMIT SET 07/0912074 <br /> D3NL5-6a ❑ ❑ <br /> LL���JII o <br /> D3NL5-8b <br /> ICI D3EH1-2 <br /> D3EH1-4c u�u. <br /> R-U-ADA 5 N SOIL D HOLD <br /> D3NL5-6a D3NL5-8b z 1 z 11 7 <br /> O 0 D2NH1-5 <br /> c <br /> b <br /> a <br /> PETIT D3NL5-8b <br /> 00 oz O O <br /> LE) D3NL5-86 CORRIDOR <br /> m <br /> D3EH1-2 <br /> DN g =� <br /> a HOLD 1 <br /> 13 INJECT-OUR NEv <br /> F2NH1-7 200.13 OFFICE CANCER <br /> O CTR DID <br /> ❑D Dols <br /> UP ❑ it IT, <br /> RRR® ❑ D3EHI-2 <br /> D _ D3EH1— CONTROL D3EH1-4 <br /> 200 04 PROJECT INFORMATION <br /> WAITING PROJECT NUMBER: B24-1032 <br /> gala <br /> PROJECT LEAD: JGG <br /> a DRAWN BY: CMB <br /> D.6 D.6 <br /> LEVEL 2- ENLARGED PET CT LIGHTING DEMOLITION PLAN e 0 2' 4' 8' SHEET NO <br /> Ei.t1 SCALE:1/4" = l'—O" E1.00—PET N 1" PLOTTED I NEIIII E 1 .11 -PET <br /> 1 2 3 4 5 6 7 6 9 10 11 <br />