Laserfiche WebLink
NOTE: <br /> Roof Secondary consolidation used can be noted in the 1 2 3 4 5 6 s 9 <br /> Secondary Part Schedule and the accompanying diagram. If <br /> consolidation needs to be done on a bay per bay basis client <br /> is responsible for additional increases in price and weight. <br /> a E7 E8 E9 E10 E9 E9 E9 E12 <br /> v r r r r r rl r r rl r rl r <br /> I <br /> P2 P7 <br /> I I <br /> I <br /> Secondary Part Schedule 17 <br /> Mark Part Thick. Depth Lap Detail <br /> E1 00108ES2511414BOI 0.0790 8 1/2" RS12PH,RSI2PA I P2 P7 <br /> E10 08E2711411DDB01 0.1130 8 1/2" RS12PA <br /> Ell 00208ES2611411BOl 0.1130 8 1/2" RS12PH,RSI2PA <br /> E12 00308ES2611411BOl 0.1130 8 1/2" RS12PH,RS12PA <br /> E7 00408ES2511414BOl 0.0790 8 1/2" RS12PH,RSI2PA I I <br /> E8 08E2511411DDB01 0.1130 8 1/2" RS12PA <br /> E9 08E2611411DDB01 0.1130 8 1/2" RS12PA P3 (TYP• ) P6(Typ.) <br /> P1 08Z2911413A5BO 0.0880 8 1/2" 3'-10 1/2" RS02T1,RSOlT1 I P1 (Typ. )— —__ P2____ P4 (TYP• PS (TYP• P4 (T YP' P6(T P8 (Typ•) I <br /> ) ) -- -- )-- --. yp•) P7 _ <br /> P2 08Z331141155BO 0.1130 8 1/2" 3'-10 1/2" RSO1T1 o P1 (Typ. ) -P2 P4 (T -- -- <br /> P3 08Z331141455B0 0.0790 8 1/2" 3'-10 1/2" RSO1T1 I YP• )-- --P5 (Typ. ) P4 (Typ. ) P6 (Typ.) P7-- — -P8 (Typ.) <br /> I <br /> P4 08Z321141544B0 0.0730 8 1/2" 2'-10 1/2" P3(TYP• ) P6 (TYP•)RSO1T1 <br /> P5 08Z351141355BO 0.0880 8 1/2" 3'-10 1/2" RS01T1 <br /> P6 08Z321141444BO 0.0790 8 1/2" 2'-10 1/2" RSO1T1 <br /> I <br /> P7 08Z321141144BO 0.1130 8 1/2" 2'-10 1/2" RSO1T1 <br /> P8 08Z3011413A5B0 0.0880 8 1/2" 3'-10 1/2" RS02T1,RSO1T1 <br /> P2 P7 <br /> I <br /> I I <br /> O Secondary Bracing Schedule I I <br /> I I <br /> Id Qty Mark No Spacing P2 P7 <br /> — <br /> 1 78 PBA0502 4'-9 15/16" <br /> See S E D: a rl rl r rl rl 1 rl ti r IS G. r N I <br /> BR09K5, BR09JG, BR09RY, BR09RZ, BR09K2 E1 E8 E9 E10 E9 E9 E9 Ell <br /> O I I I O <br /> 251-0"- 1 261-0" 271-0" 281-0" 271-0" 271-0" 271-011 26'-0" 1 <br /> 215'-0" I I <br /> BL BL <br /> W ES <br /> ROOF SECONDARY PLAN O��pF WAS `sE`� <br /> OPart Mark Key <br /> 1 RCHB15 56 92 <br /> T <br /> NAIL <br /> 1 <br /> 04/08/2019 <br /> Dimension Key <br /> Shape Name=Cadman 1 PERMIT SET-For Building Dept.Approval <br /> THE VP ENGINEER'S SEAL APPLIES ONLY THIS DRAWING,INCLUDING THE INFORMATION HEREON,REMAINS THE PROPERTY OF <br /> 1.UNLESS NOTED,USE 1/2 X 1 1/2 A325T BOLT(49080)AND NUT(47120) TO THE WORK PRODUCT OF VP AND VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBEDBI <br /> VP Buildings <br /> W/O WASHERS.SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS. DESIGN AND PERFORMANCE IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT 3200 Players Club Cirde Memphis TN 38126 ROOF SECONDARY PLAN <br /> 2.FLANGE BRACES ARE AN INTEGRAL PARTOF THE STABILITY OF THE REQUIREMENTS SPECIFIED BY VP. THE PURPOSE. IT SHALL NOT BE MODIFIED,REPRODUCED OR USED FOR ANY OTHER <br /> S <br /> STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION VP ENGINEER'S SEAL DOES NOT APPLY PURPOSE WITHOUT PRIOR N APPROVAL F VP BUILDINGS. REV DATE BY DE CRPTION BULDER 18- <br /> CHG Building Systems,Inc. 18-040734 <br /> OF WALL AND ROOF SHEETS. TO THE PERFORMANCE OR DESIGN OF THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE CUSTOMERCadman <br /> DATE <br /> ANY OTHER PRODUCT OR COMPONENT GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS Everett,Washington VP BUILDINGS <br /> 3.REMOVAL OR ALTERATION OF ANY COMPONENT IS PROHIBITED. LocnnoN 4.5.2019 <br /> FURNISHED BY VP EXCEPT TO ANY DRAWING,DETAILS REFERENCED IN THIS DRAWING,ALL APPLICABLE VP BUILDINGS DRAWWCHECK <br /> DESIGN OR PERFORMANCE ERECTION GUIDES,AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, PRaecT Cadman Everett Bldg 1 tE jaC <br /> REQUIREMENTS SPECIFIED BY VP. INCLUDING THE CORRECT USE OF TEMPORARY BRACING. NITS JBULOERS Pap 28103 VPC VERBION: 2018.2b PAGE 16 <br /> 4/4/2019 16:47:10 FILENAME:Cadman 1-APD a tllNalan of BlwSwpe Buildings North Amanoa,ho. <br />