My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
17 E MARINE VIEW DR 2019 Plans 2025-09-29 (4)
>
Address Records
>
E MARINE VIEW DR
>
17
>
Plans
>
17 E MARINE VIEW DR 2019 Plans 2025-09-29 (4)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2025 2:05:41 PM
Creation date
9/29/2025 1:39:18 PM
Metadata
Fields
Template:
Address Document
Street Name
E MARINE VIEW DR
Street Number
17
Permit
B1904-034
B1904-035
Year
2019
Notes
SOIL REMEDIATION RECYCLING FACILITY BY CADMAN
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Codes and Loads <br /> WHEN MULTIPLE BUILDINGS ARE INVOLVED, SPECIFIC LOAD FACTORS FOR DIFFERING OCCUPANCIES, BUILDING DIMENSIONS, <br /> HEIGHTS, FRAMING SYSTEMS, ROOF SLOPES, ETC., MAY RESULT IN DIFFERENT LOAD APPLICATION FACTORS THAN <br /> INDICATED BELOW. SEE CALCULATIONS FOR FURTHER DETAILS. WIND LOADS ARE APPLIED TO OVERALL BUILDING ENVELOPE. <br /> COMMON WALLS BETWEEN CONNECTED SHAPES ARE NOT SUBJECT TO EXTERNAL WIND LOADS. <br /> City: Everett County: Snohomish State: Washington Country: United States <br /> Building Code <br /> Building Code: 2015 International Building Code Structural: 10AISC - ASD Rainfall: I: 4.00 inches per hour <br /> Building Risk/Occupancy Category: II (Standard Occupancy Structure) Cold Form: 12AISI - ASD f'c: 3000.00 psi Concrete <br /> Dead and Collateral Loads Material Dead Weight Roof Live Load <br /> Roof Live Load: 20.00 psf Reducible <br /> Collateral Gravity:5.00 psf Roof Covering + Second. Dead Load: 1.89 psf p <br /> Collateral Uplift: 3.00 psf Frame Weight (assumed for seismic) :3.60 psf - USR <br /> Wind Load Snow Load <br /> Seismic Load <br /> Wind Speed: Vult: 110.00 (Vasd: 85.21) mph Ground Snow Load: pg: 25.00 psf Lateral Force Resisting Systems using Equivalent Force Procedure <br /> The 'Envelope Procedure' is Used Flat Roof Snow: pf: 18.90 psf Mapped MCE Acceleration: Ss: 142.00 %g <br /> 54 S1 ti <br /> Mapped MCE Acceleration: : .10 �g <br /> Wind Exposure: C - Kz: 0.998 Design Snow (Sloped) : ps: 18.90 psf Y <br /> Parts Wind Exposure Factor: 0.998 Rain Surcharge: 0.00 Site Class: Stiff soil (D) <br /> Wind Enclosure: Free Roof - Clear/Obstr Specified Minimum Roof Snow: 25.00 psf (USR) Seismic Importance: Ie: 1.000 <br /> Topographic Factor: Kzt: 1.0000 Exposure Factor: 1 Fully Exposed - Ce: 0.90 Design Acceleration Parameter: Sds: 0.9467 <br /> Snow Importance: Is: 1.000 <br /> Design Acceleration Parameter: Shc: 0.5410 X <br /> NOT Windborne Debris Region Thermal Factor: Unheated - Ct: 1.20 Seismic Design Category: D <br /> Base Elevation: 0/0/0 Ground / Roof Conversion: 0.70 Seismic Snow Load: 0.00 psf <br /> Primary Zone Strip Width: 2a: 32/4/0 <br /> Snow Used in Seismic: 0.00 Cadman 1 <br /> Parts / Portions Zone Strip width: a: 12/0/0 <br /> Diaphragm Condition: Flexible Roof: B <br /> Basic wind Pressure: q: 26.27 psf Fundamental Period Height Used: 32/4/0 <br /> Cadman 1 <br /> Roof: A <br /> Transverse Direction Parameters <br /> Ordinary Steel Moment Frames <br /> Redundancy Factor: Rho: 1.30 X <br /> Fundamental Period: Ta: 0.4517 <br /> R-Factor: 3.50 Y <br /> Overstrength Factor: Omega: 2.50 <br /> Deflection Amplification Factor: Cd: 3.00 <br /> Base Shear: V: 0.2705 x W <br /> Longitudinal Direction Parameters <br /> Ordinary Steel Concentric Braced Frames <br /> Redundancy Factor: Rho: 1.30 <br /> Fundamental Period: Ta: 0.2712 <br /> R-Factor: 3.25 <br /> Overstrength Factor: Omega: 2.00 <br /> Deflection Amplification Factor: Cd: 3.25 <br /> Base Shear: V: 0.2913 x W C <br /> Snow Buildup <br /> Shape Surface Description X Location Y Location Magnitude �� wss� <br /> Cadman 1 Roof: A Unbalanced Snow Load 1, Shifted Left Roof: A 0.0 ft 24.0 ft 12.9 psf <br /> 0.0 ft 0.0 ft 12.9 psf y <br /> 215.0 ft 0.0 ft 12.9 psf <br /> 215.0 ft 24.0 ft 12.9 psf <br /> Cadman 1 Roof: B Unbalanced Snow Load 1, Shifted Right : Roof: B 0.0 ft 24.0 ft 12.9 psf 56 92 <br /> 0.0 ft 0.0 ft 12.9 p s f min '�'C(WEi <br /> 215.0 ft 0.0 ft 12.9 psf �s`s� )NAIL <br /> 215.0 ft 24.0 ft 12.9 psf <br /> 1. The Snow Buildup loading shown is in addition to the flat or sloped roof snow. 04/08/201Q <br /> 2. The X and Y Location dimensions are from the point of origin of each surface. <br /> PERMIT SET-For Building Dept.Approval <br /> THE VP ENGINEER'S SEAL APPLIES ONLY THIS DRAWING,INCLUDING THE INFORMATION HEREON,REMAINS THE PROPERTY OF <br /> TO THE WORK PRODUCT OF VP AND VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED VP Buildings BI <br /> DESIGN AND PERFORMANCE IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT 3200 Players Club Circle Memphis TN 38125 CODES AND LOADS <br /> REQUIREMENTS SPECIFIED BY VP. THE PURPOSE. IT SHALL NOT BE MODIFIED,REPRODUCED OR USED FOR ANY OTHER <br /> VP ENGINEER'S SEAL DOES NOT APPLYPURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP REVI DATE I ByDESCPON BULDER <br /> CHG Building Systems,Ina oe a <br /> TO THE PERFORMANCE OR DESIGN OF THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE CUS70MIR Cadman DATE <br /> LOCATION Everett,Washington 4.5.201 <br /> 18-040734 <br /> ANY OTHER PRODUCT OR COMPONENT GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS VP BUILDINGS 9 <br /> FURNISHED BY VP EXCEPT TO ANY DRAWING,DETAILS REFERENCED IN THIS DRAWING,ALL APPLICABLE VP BUILDINGS DRAW5.201K <br /> DESIGN OR PERFORMANCE ERECTION GUIDES,AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, PRGJECT Cadman Everett Bldg 1 jac <br /> REQUIREMENTS SPECIFIED BY VP. INCLUDING THE CORRECT USE OF TEMPORARY BRACING. NITS 1BULDERS PC# 28103 VPC VERSION: ZO1 S.2h PAGE2 <br /> 4/4/2019 16:46:50 FILENAME:Cadman 1 a diAslon of BlusScope Buildings NoMAnsdca,Ic. <br />