Z—PURLIN GENERAL NOTES <br /> Z—PURLIN Z—PURLIN <br /> ONNECTION TO PR IN 1, CONCENTRATED LOADS GREATER THAN 5001bs ON ANY SINGE PURLIN MUST BE EXPLICITLY LOCATED AND DESIGNED <br /> NO UT BY BLUESCOPE� ONNECTION TO PUR IN FOR DURING DESIGN OF BUILDING SYSTEM. <br /> ANGLE HANGER NOT BY BLUESCOPE) <br /> ONNECTION TO PUR IN 2. SPECIFIED COLLATERAL OADS MAY BE CONVERTED TO SAFE CONCENTRATED LOADS AS FOLLOWS, WHERE P = MAX <br /> NOT BY BLUESCO CONCENTRATED LOAD Ibs ; W = UNIFORM COLLATERAL LOAD (PSF) x PURLIN SPACING (ft) = Ibs/ft; L = PURLIN <br /> NLENT PLATE OR STRAP SPAN (ft). HANGERS SHOULD BE SPACED APPROX. EQUAL <br /> 1 HANGER LOAD HANGER LOAD I OT BY BLUESCOPE) I iIP I P IP 1 P I P <br /> `HANGER LOAD P MAX= 0.5w1 P MAX= 0.4wl P MAX= 0.25w1 <br /> WEB HANGERS <br /> POURLIN MUST BEBEBOLT TO SPECIFICALLY PURLIN <br /> DESICONNECTION— <br /> OR LOADSX HANGER GREATER THAN 500 GLIbs <br /> B. SEE NOTE #2. 1P p �P p r 1P lP �P IP 6 OR MORE HANGERS PER PURLIN <br /> + i i P MAX= W x HANGER SPACING <br /> P MAX= 0.2wl P MAX= 0.15w1 <br /> WIDE THROAT BEAM EXAMPLE; A PIPE IS SUSPENDED FROM A PURLIN AT 3 LOCATIONS EQUALLY SPACED <br /> C—CLAMP MUST NOT BAY SPACING = 24'-0" PURLIN SPACING = 6-0" <br /> BEND OR CONTACT <br /> PURLIN LIP (NOT Z—PURLIN SPECIFIED COLLATERAL LOAD = 5 PSF <br /> BY BLUESCOPE) HALF FLANGE W = 5 PSF x 5 FT = 25 PLF L = 24'-0* <br /> WIDTH HALF FLANGE PMAX — 0.25 x 25 PLF x 24'—D" — 150 LEIS AT EACH LOCATION <br /> WIDTH FIELD DRILL HOLE THE PURLIN CAN SUPPORT 3 LOADS UP TO 150 LBS EACH. PICK A HANGER CONNECTION <br /> Z— PURLIN FOR ROD IN BOTTOM CAPABLE OF SUPPORTING ACTUAL APPLIED LOADS. <br /> DO NOT USE A HANGER DEVICE F G� OF PURLIN <br /> AT CAU S DEFORMATION HANGER ROD (7 ' MAX HOLE) 3. FOR LOADS GREATER THAN 250 Ibs, PURLINS MUST BE "BLOCKED" AT LOCATION OF LOAD TO PREVENT PURLIN ROTATION. <br /> (FLATTENING OF THIS FLANGE LIP NOT BY <br /> 16 <br /> MJESCOPE) 4. EQUIPMENT LOADS SHOULD BE OBTAINED FROM CERTIFIED EQUIPMENT DRAWINGS AND MANUFACTURER'S DATA. <br /> VERIFY OVERALL PURLIN DESIGN CAN TAKE APPLIED LOADS. SEE NOTE #2 5_ Z—PURLINS WILL DEFLECT UNDER SNOW AND WIND LOADS- ITEMS THAT MAY BE DAMAGED DUE TO DEFLECTIONS, (EX. GAS <br /> LINES), VERIFY THAT PIPES OR SUSPENDED EQUIPMENT ARE COMPATIBLE WITH EXPECTED DEFLECTION RANGES (}-L/180), <br /> MAXIMUM LOAD SUSPENDED FROM BOTTOM FLANGE 6. THE NATIONAL FIRE PRDTECT10N ASSOCIATION [NFPA) REQUIRES SPRINKLER HANGERS TO BE DESIGNED FOR A <br /> (LOCATED AT HALF—FLANGE WIDTH) MINIMUM LOAD OF FIVE TIMES THE WEIGHT OF THE WATER—FILLED PIPE PLUS 250 POUNDS, THE HANGER ITSELF MUST <br /> BE ABLE TO SUPPORT THIS LOADING IT IS NOT NECESSARY TO DESIGN THE SUPPORTING MEMBER FOR THIS LOAD IN <br /> THICKNESS MAX LOAD THICKNESS MAX LOAD COMBINATION WITH THE DESIGN LOADS. <br /> 0,060" 1101bs 0.088" 20011>s 7. SUSPENDED LOADS WILL NEED TO BE BRACED (TO THE PRIMARY FORCE RESISTING SYSTEM) FOR LATERAL STABILITY DUE <br /> 0.068" 1201 b s <br /> TO EARTHQUAKES, <br /> 0.073" 1401b s 0_D98" 250Ibs B. HANGER DESIGN IS NOT THE RESPONSIBILITY OF BLUESCOPE. <br /> 0.079" 1801bs 0.113" 2501bs 9. TOP FLANGE,H IF TOP FLANGE ANGERS AVOIDED <br /> EOREQUIILRDEID PLACE WITHOUT <br /> INSULATION <br /> AT THEE ROOFO PANEOL MAJOR OF <br /> LOCATION TO AVOID DAMAGING THE ROOF PANEL WITH THE HANGER WHEN THE ROOF PANEL IS LOADED OR WALKED ON. <br /> FOR LOADS LOCATED MORE THAN HALF FLANGE WIDTH <br /> FROM WEB, USE HALF OF THE LOADS SHOWN ABOVE_ 10_ WHEN BEAM C—CLAMPS OR OTHER ROD HANGERS ARE USED ON THE TOP FLANGE, THE ROD SHOULD NOT EXTEND ABOVE <br /> THE TOP OF THE CLAMP TO AVOID DAMAGING THE ROOF PANEL WITH THE ROD WHEN THE ROOF PANEL IS LOADED OR <br /> WALKED ON. <br /> BOTTOM FLANGE CLAMP HANGER BOTTOM FLANGE ROD HANGER <br /> (TOP FLANGE SIMILAR) (TOP FLANGE SIMILAR) 11. DO NOT HANG ANY TYPE OF CRANE, HOIST, CONVEYOR OR ANY MOVING LOADS FROM THE Z—PURLINS. <br /> DO NOT USE ANY OF THE DETAILS ABOVE IF ROOF SLOPE IS GREATER THAN 4:12 12. DO NOT HANG ANY LOAD FROM BBNA SUPPLIED PURLIN BRACES OR BRIDGING_ <br /> 13. DO NOT WELD ANY PART OF THE Z—PURLIN, <br /> Z—PURLIN HANGER ASSEMBLY <br /> (NOT BY BLUESCOPE) 14, HOLES MUST NOT EXCEED 9/16" DIAMETER UNLESS AUTHORIZED BY BBNA ENGINEER. DRILL OR REAM HOLES WHEN <br /> Z—PURLIN REQUIRED— DO NOT FLAME CUT <br /> R+ RI <br /> HALF FLANGE I HALF FL NGE �1K W <br /> TH WAS,y� <br /> TABTABOVE FOR (ANGER ASSEMBLY ) <br /> NOT BY BLUESCOPE <br /> EACRLIN <br /> HANGER LOAD HANGER LOAD 56 92 <br /> 1STEi \� <br /> DOUBLE PURLIN HANGERS NALL CDNCENTRATED LOADS ON RDOF <br /> Z—PURLIN HANGER DETAILS <br /> VERIFY OVERALL PURLIN DESIGN CAN SUPPORT APPLIED LOADS, MtA"UT OECKM D1 NUMBER; 60-054-01 <br /> U4/u8/2019 REVERITT RSENTON <br /> ,I RST ROGASC O TC REV@OI DATE Lz <br /> 08146 5 107 <br /> 02 2fi 10 11 20 13 <br /> PERMIT SET-For Building Dept.Approval <br /> THE VP ENGINEER'S SEAL APPLIES ONLY THIS DRAWING,INCLUDING THE INFORMATION HEREON,REMAINS THE PROPERTY OF VP Buildings <br /> TO THE WORK PRODUCT OF VP AND VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED BI <br /> 3200 Players Club Circle Memphis TN 38125 CONCENTRATED LOADS ON ROOF <br /> DESIGN AND PERFORMANCE IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT <br /> REQUIREMENTS SPECIFIED BY VP. THE PURPOSE. IT SHALL NOT BE MODIFIED,REPRODUCED OR USED FOR ANY OTHER BUILDER JOB n <br /> VP ENGINEER'S SEAL DOES NOT APPLY PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. Rev DATe ev DEscR�PnoN CHG Building Systems,Inc. <br /> 18-040734 <br /> TO THE PERFORMANCE OR DESIGN OF THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE C`uTo"Cadman DATE <br /> ANY OTHER PRODUCT OR COMPONENT GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS 111CAT'o"Everett,Washington VP BUILDINGS 4.5.2019 <br /> FURNISHED BY VP EXCEPT TO ANY DRAWING,DETAILS REFERENCED IN THIS DRAWING,ALL APPLICABLE VP BUILDINGS R o�wN D—WCHEDK <br /> DESIGN OR PERFORMANCE ERECTION GUIDES,AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, PRaeCT Cadman Everett Bldg 1 jac <br /> REQUIREMENTS SPECIFIED BY VP. INCLUDING THE CORRECT USE OF TEMPORARY BRACING. NITS BULDERS PC# 28103 vacvERsioN 2018.2b PAGE29 <br /> 4/5/2019 11:54:42 E`Ew ME!Cadman 1 xaws o"ot Bi esooPa emm y wrt ame,ca.uc <br />