My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
17 E MARINE VIEW DR 2019 Plans 2025-09-29 (4)
>
Address Records
>
E MARINE VIEW DR
>
17
>
Plans
>
17 E MARINE VIEW DR 2019 Plans 2025-09-29 (4)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2025 2:05:41 PM
Creation date
9/29/2025 1:39:18 PM
Metadata
Fields
Template:
Address Document
Street Name
E MARINE VIEW DR
Street Number
17
Permit
B1904-034
B1904-035
Year
2019
Notes
SOIL REMEDIATION RECYCLING FACILITY BY CADMAN
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REQUIRED VERIFICATION AND INSPECTION OF STEEL CONSTRUCTION REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION <br /> VERIFICATION AND INSPECTION CONTINUOUS PERIODIC REFERENCED IBC REFERENCE VERIFICATION AND INSPECTION CONTINUOUS PERIODIC REFERENCED BC REFERENCE <br /> STANDARD STANDARD <br /> 1. MATERIAL VERIFICATION OF HIGH-STRENGTH BOLTS,NUTS AND WASHERS: 1. INSPECTION OF REINFORCEMENT,INCLUDING PRESTRESSING TENDONS, ACI 318:CH.20,25.2, <br /> AISC 360,SECTION A3.3 AND VERIFY PLACEMENT - X 25.3,26.1-26.3 1908.4 <br /> A.IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS V AND APPLICABLE ASTM <br /> SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS X MATERIAL STANDARDS <br /> S.MANUFACTURER'S CERTIFICATE OF COMPLIANCE REQUIRED - X - - 2. INSPECTION OF REINFORCING STEEL WELDING IN ACCORDANCE WITH - - AWS D1.4 - <br /> TABLE 1705.3,REM 2 ACI 318:26.6.4 <br /> 2. INSPECTION OF HIGH-STRENGTH BOLTING: <br /> A.SNUG-TIGHT JOINTS - X 3. INSPECT ANCHORS CAST IN CONCRETE - X 8.1.3I,21 2.8 - <br /> B.PRETENSIONED AND SUP-CRITICAL JOINTS USING TURN-OF-NUT 4. INSPECT ANCHORS POST-INSTALLED IN HARDENED CONCRETE IN ACI 318: <br /> WITH MATCHMARKING,TWIST-OFF BOLT OR DIRECT TENSION INDICATOR - X AISC 360, ACCORDANCE WITH TABLE 1705.3.ITEM 4. 17.8.2.4,17.8.2 - <br /> METHODS OF INSTALLATION SECTION M2.5, 1704.3.3 <br /> N5.6 5. VERIFYING USE OF REQUIRED DESIGN MIX - X ACI 318: 1904.1,190 1908.2, <br /> C.PRETENSIONED AND SLIP-CRITICAL JOINTS USING TURN-OF-NUT CH.19,26.4.3,26.4.4 1908.38.3 <br /> WITHOUT MATCHMARKING OR CALIBRATED WRENCH METHODS OF X - 6. PRIOR TO CONCRETE PLACEMENT,FABRICATE SPECIMENS FOR ASTM C 172 <br /> INSTALLATION STRENGTH TESTS,PERFORM SLUMP AND AIR CONTENT TESTS,AND X - ASTM C 31 1908.10 <br /> DETERMINE THE TEMPERATURE OF THE CONCREFE. ACI 318:26.4,26.12 <br /> 3. MATERIAL VERIFICATION OF STRUCTURAL STEEL AND COLD-FORMED STEEL DECK: <br /> 7. INSPECT CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER 1908.6.1908.7, <br /> A.FOR STRUCTURAL STEEL,IDENTIFICATION MARKINGS TO CONFORM _ AISC 360, APPLICATION TECHNIQUES. X - ACI 318:26.5 1908.8 <br /> TO AISC 360 X SECTION M5.5 <br /> 8. VERIFY'MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND ACI 318:26.5.3-26.5.5 1908.9 <br /> B.FOR OTHER STEEL,IDENTIFICATION MARKINGSASTM O CONFORM TO APPLICABLE ASTM TECHNIQUES. <br /> DOCUMENTS X - X <br /> STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION - MATERIAL STANDARDS <br /> DOCUMENTS <br /> 9. INSPECT PRESTRESSED CONCRETE FOR: <br /> C.MANUFACTURER'S CERTIFIED TEST REPORTS - X A. APPLICATION OF PRESTRESSING FORCES;AND X - ACI 318:2610 - <br /> 4. MATERIAL VERIFICATION OF WELD FILLER MATERIALS: B. GROUTING OF BONDED PRESTRESSING TENDONS V <br /> AISC 360,SECTION 10. INSPECT ERECTION OF PRECAST CONCRETE MEMBERS - X ACI 318:CH.26.8 <br /> A.IDENTIFICATION MARKINGS TO CONFORM TO AWS SPECIFICATION IN _ A3.5,N5.4-5.5,AND _ <br /> THE APPROVED CONSTRUCTION DOCUMENTS X APPLIN5.4CABLE AWS A5 <br /> DOCUMENTS 11. VERIFY IN-SITU CONCRETE STRENGTH,PRIOR TO STRESSING OF <br /> TENDONS IN POST-TENSIONED CONCRETE AND PRIOR TO REMOVAL OF - X ACI 318:26.11.2 - <br /> B.MANUFACTURER'S CERTIFICATE OF COMPLIANCE REQUIRED - X - - SHORES AND FORMS FROM BEAMS AND.IN <br /> SLABS. <br /> 5. INSPECTION OF WELDING: <br /> 12. INSPECT FORMWORK FOR SWIPE,LOCATION AND DIMENSIONS OF THE ACI 318:26.11.1.2 b <br /> A.STRUCTURAL STEEL AND COLD-FORMED STEEL DECK: CONCRETE MEMBER BEING FORMED - X ) <br /> 1)COMPLETE AND PARTIAL JOINT PENETRATION GROOVE WELDS X - <br /> 2)MULTIPASS FILLET WELDS X - <br /> V AWS D1.1,AISC 360 REQUIRED VERIFICATION AND INSPECTION OF SOILS <br /> 3)SINGLE-PASS FILLET WELDS>5/16" /� - N5.4-5.5 1704.3.1 <br /> 4)PLUG AND SLOT WELDS X - CONTINUOUS DURING PERIODIC DURING <br /> VERIFICATION AND INSPECTION TASK TASK LISTED TASK LISTED <br /> 5)SINGLE-PASS FILLET WELDS<OR=5/16" - X <br /> - AWS D1.3 1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO <br /> 6 FLOOR AND ROOF DECK WELDS - <br /> X ACHIEVE THE DESIGN BEARING CAPAM X <br /> B.REINFORCING STEEL 2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE <br /> REACHED PROPER MATERIAL - X <br /> 1)VERIFICATION OF WELDABIUTY OF REINFORCING STEEL OTHER - X <br /> THAN ASTM A 706 3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS - X <br /> 2)REINFORCING STEEL RESISTING FLEXURAL AND AXIAL FORCES 4. VERIFY USE OF PROPER MATERIALS,DENSITIES AND LIFT THICKNESSES - <br /> IN INTERMEDIATE AND SPECIAL MOMENT FRAMES,AND X - DURING PLACEMENT AND COMPACTION OF COMPACTED FILL X <br /> BOUNDARY ELEMENTS OF SPECIAL STRUCTURAL WALLS OF <br /> CONCRETE AND SHEAR REINFORCEMENT AWS D1A ACI 318: 5. PRIOR TO PLACEMENT OF COMPACTED FILL,OBSERVE SUBGRADE AND - <br /> SECTION 3.5.2 VERIFY THAT SITE HAS BEEN PREPARED PROPERLY X <br /> d 3)SHEAR REINFORCEMENT X - <br /> 4)OTHER REINFORCING STEEL - X <br /> 6. INSPECTION OF STEEL FRAME JOINT DETAILS FOR COMPLIANCE: <br /> A.DETAILS SUCH AS BRACING AND STIFFENING - X <br /> B.MEMBER LOCATIONS - X - 1704.3.2, 1704.3.3 <br /> C.APPUCATON OF JOINT DETAILS AT EACH CONNECTION - X <br /> SPECIAL INSPECTION NOTES: <br /> 1. TESTING AND SPECIAL INSPECTION REPORTS SHALL BE PREPARED FOR EACH INSPECTION ITEM ON A DAILY BASIS WHENEVER WORK IS PERFORMED ON THAT ITEM.REPORTS SHALL BE <br /> F. DISTRIBUTED TO OWNER,CONTRACTOR,BUILDING OFFICIAL AND STRUCTURAL ENGINEER, <br /> 2. STRUCTURAL OBSERVATIONS SHALL BE PREFORMED BY THE STRUCTURAL ENGINEER OF RECORD OR DESIGNATED REPRESENTATIVE IN ACCORDANCE WITH IBC.STRUCTURAL OBSERVATION <br /> SHALL BE PERFORMED AS FOLLOWS: <br /> L 2.A. PERIODIC VISUAL OBSERVATIONS OF THE STRUCTURAL SYSTEM FOR GENERAL CONSTRUCTION DOCUMENTS AT SIGNIFICANT CONSTRUCTION PHASES. <br /> Y 2.8. RENEW OF TESTING AND INSPECTON REPORTS. <br /> 2.C. REPORTS SHALL BE PREPARED FOR EACH SITE VISIT AND SHALL BE DISTRIBUTED TO THE ENGINEER. <br /> „ 3. GENERAL CONTRACTOR SHALL SUBMIT A WRITTEN CONTRACTOR'S STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND OWNER PRIOR TO COMMENCEMENT OF WORK.THE <br /> CONTRACTOR'S STATEMENT OF RESPONSIBILITY SHALL INCLUDE THE FOLLOWING: `*IrY. <br /> 3.A. ACKNOWLEDGEMENT OF AWARENESS FOR REQUIREMENTS OF QUALITY ASSURANCE PLAN. REVIEI;'J I_r(I_T T <br /> t <br /> R PERM! <br /> 3.B. ACKNOWLEDGEMENT THAT CONTROL WILL BE EXERCISED TO OBTAIN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS APPROVED BY THE BUILDING OFFICIAL. <br /> 3.C. PROCEDURES FOR EXERCISING CONTROL WITHIN THE CONTRACTORS ORGANIZATION AND THE FREQUENCY OF REPORTING AND DISTRIBUTING. <br /> 3.D. IDENTIFICATION OF PERSONS EXERCISING SUCH CONTROL AND THEIR POSITIONS IN THE ORGANIZATION, <br /> THIS DRAWNG,INCLUDING THE PRINCIPLES <br /> _ OF DESIGN IS THE PROPERTY OF SMG INC. 8625 SW Cascade Ave. <br /> °1 THE DESIGN SHOWN IN THIS DRAWING IS Suite 800 <br /> SITE SPECIFIC AND SHALL BE USED ONLY CADMAN HEIDELBERG CEMENT GROUP <br /> w FOR THE PROJECT SHOWN 0x THE TIRE po Beaverton,Oregon 9700e EVERETT DELTA SOIL REMEDIATION FACILITY <br /> BLOCK.IF THIS DRAWING IS NOT STAMPED �y w <br /> WITH AN ENGINEER'S SEA,THE DRAWING - ' _ Smith Monroe Gray Phone:503.643.8595 <br /> 3 MAY HAVE BEEN REPRODUCED FROM AN Fax:508.643.8610 STATEMENT OF SPECIAL INSPECTIONS <br /> UONFROORREO COPY.AUTHORIZED <br /> CARD CL DOCUMENF IS ERRO A STAMPED ENGINEERS, INC. <br /> HAND COPY <br /> aft DRAWING <br /> HALL NOT <br /> e vmw.smgengr.com <br /> ORIGINAL THY$DRAWING SHALL NOi BE .P <br /> USED IN A MANNER THAT WOULD BE A NAc DRAWN BY DATE CHKD BY DATE SGLE DWG,10. REV. <br /> DETRIMENT TO SAG.ACCEPTANCE OF MIS <br /> DRAWING IS AN AGREEMENT TO ME ABOVE. 0 ISSUED FOR PERMIT .row 62619 JLP �-Z.�/2 C,0 JA2.VJAAACE t2/20/18 AS NOTED 18-181A-02 0 <br /> SIAI. REVISIONS BY DATE GHN'D <br />
The URL can be used to link to this page
Your browser does not support the video tag.