17 E MARINE VIEW DR 2019 Plans 2025-09-29 (4)
>
Address Records
>
E MARINE VIEW DR
>
17
>
Plans
>
17 E MARINE VIEW DR 2019 Plans 2025-09-29 (4)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2025 2:05:41 PM
Creation date
9/29/2025 1:39:18 PM
Metadata
Fields
Template:
Address Document
Street Name
E MARINE VIEW DR
Street Number
17
Permit
B1904-034
B1904-035
Year
2019
Notes
SOIL REMEDIATION RECYCLING FACILITY BY CADMAN
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/ <br /> /I BUILDING CODE SUMMARY <br /> / I STORAGE STRUCTURE(CADMAN 11 <br /> DIMENSIONS:120'x 215'x 34'-10'MAX.RIDGE HEIGHT <br /> / I 200'SHORELINE AREA =25,800 SQ.Fr. <br /> —— MANAGEMENT OCCUPANCY CATEGORY =S-2 <br /> (SMZ ZONE(SMZ) OCCUPANT LOAD =52 OCCUPANTS(IBC 2015 TABLE 1004.1.2) <br /> — — ——— (NS) BUILDING NOT EQUIPPED THROUGHOUT WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM <br /> CONSTRUCTION TYPE =TYPE IIB CONSTRUCTION <br /> FIRE RESISTANCE RATING FOR BUILDING ELEMENTS: <br /> _ _ _ PRIMARY STRUCTURAL FRAME =0 HOURS <br /> — ROOF CONSTRUCTION =0 HOURS <br /> // - =•..� BASIC ALLOWABLE AREA(Ad) =26,000 SO.Fr.(IBC TABLE 506.2) <br /> _••_ "'_`.�.,_,ti� AREA/Aa=0.99(<1.0) <br /> LEASE BOUNDARY <br /> ALLOWABLE HEIGHT =55'(IBC TABLE 504.3) <br /> CROSS BRACING <br /> NOTE:NO HAZARDOUS OR COMBUSTIBLE MATERIAL PERMITTED TO BE STORED IN BUILDING. <br /> .) �."`��•—�„� <br /> TYP,(4)PLACES /M �i � _ <br /> / AT / PROCESS FACILITY STRUCTURE(CADMAN 21 <br /> DIMENSIONS:120'x 201'x 45'MAX.RIDGE HEIGHT <br /> / / f AREA =24,120 SQ.FT.(9,000 DESIGNATED S-2;15,120 DESIGNATED F-2) <br /> !� \� tj �� /•:/� OCCUPANCY CATEGORY =F-2 OR S-2(MIXED—USE) <br /> OCCUPANT LOAD =242 OCCUPANTS(IBC TABLE 1004.1.2) <br /> Jt,7 MAX EXIT OISfANCE , i ( (NS) BUILDING NOT EQUIPPED THROUGHOUT WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM <br /> EQUALS-110 CONSTRUCTION TYPE =TYPE IIB CONSTRUCTION <br /> I I FIRE RESISTANCE RATING FOR BUILDING ELEMENTS: <br /> PRIMARY STRUCTURAL FRAME =0 HOURS <br /> / ROOF CONSTRUCTION =0 HOURS <br /> EXIT DISTANCE BASIC ALLOWABLE AREA(S-2) =26,000 SQ.FT.(IBC TABLE 506.2) <br /> EQUALS 60' �; !IT-f�/ I / BASIC ALLOWABLE AREA(F-2) =23,000 SQ.FT.(IBC TABLE 506.2) <br /> "I S-2 AREA MODIFICATIONS(IBC 506.2.1): <br /> AD=(At+ x If NS <br /> 7 � ( ))=ALLOWABLE AREA <br /> STORAGE—CADMAN 1 <br /> NS=26,000 SQ.FF.=NOT SPRINKLERED ALLOWABLE AREA <br /> // I•:/! At=26,000 SQ.FT.=BASIC ALLOWABLE AREA <br /> I TOTAL AREA=25,800 SF ! CROSS BRACING PROCESS—CADMAN 2 _Y <br /> OCCUPANT LOAD=52 1! TYP,(2)PLACES <br /> / �� TOTAL AREA=24,120 SF' i j FRONTAGE INCREASE(IBC 506.3) <br /> OCCUPANT LOAD 8=((F/P)-0.25)x(W/30)=AREA FACTOR INCREASE DUE TO FRONTAGE F=642 FT=BUILDING PERIMETER THAT FRONTS AN OPEN SPACE>20 Fr <br /> P=642 Fr=PERIMETER OF ENTIRE BUILDING <br /> W=30 FT=AVERAGE PUBLIC WAY OR OPEN SPACE AROUND BUILDING PERIMETER,30 FT MAX. <br /> If 0.75 <br /> /�1(I lE( Aa=45, 20500 FT. <br /> gr��f \ 1 J l ..1� <br /> F-2 AREA MODIFICATIONS(IBC 506. ): <br /> Ad=(At+(NS x If))=ALLOWABLELE AREA <br /> NS=23DOD SQ.Fr.=NOT SPRINKLERED ALLOWABLE AREA <br /> At=23,600 SO.FT.=BASIC ALLOWABLE AREA <br /> ca = _ _ _ If=0.75 <br /> �i A.=40,250 SQ.Fr. <br /> AREA/A.=0.38 <br /> 1i TOTAL AREA DEMAND=0.58(<1.0) <br /> ALLOWABLE HEIGHT =55'(IBC TABLE 504.3) <br /> NOTE:NO HAZARDOUS OR COMBUSRBLE MATERIAL PERMITTED TO BE STORED IN BUILDING. <br /> I I ' MEANS OF EGRESS: <br /> COMMON PATH OF EGRESS TRAVEL =75 FT.MAXIMUM(IBC TABLE 1006.2.1) <br /> EXIT ACCESS TRAVEL DISTANCE =300 Fr.MAXIMUM(IBC TABLE 1017.2) <br /> 5 <br /> LEASE <br /> 6 BOUNDARY <br /> B � <br /> Q SITE PLAN - BUILDING EGRESS PLAN <br /> 6 <br /> tl <br /> ` <br /> U THIS DRNNNG,INCLUDING THE PRINCIPLES <br /> 5 OF DESIGN IS THE PROPERTY OF SMG INC. 8625 SWSuite <br /> e Cascade Ave <br /> w <br /> �S61CI�AND Sl N BE USED ONLY Beaverton,Oregon 9700E CADMAN HEEDELBERG CEMENT GROUP <br /> r Al FOR ME PROJECT 310WN ON THE TIRE EVERETf DELTA SOIL REMEDWTION FACILITY <br /> BLOCK.IF THIS DRAWING IS NOTE STAMPED <br /> WITH AN ENGINEER'S SEAT_1HE DRAWING Phone:503.643.8595 <br /> SIE A MAY MW BEEN REPRODUCED FROM AN Smith Monroe Gray Fax:503.643.8610 NEW PRE-ENGINEERED BUILDINGS <br /> CONTROLL DOOCCUMENT ISS ETHERR AA STA!APED ENGINEERS, INC.COW AUTHORIZED <br /> SCOTT I EDWARDS ARCHITECTURE LLP HARD COW OR DIGITALLY PROTECTED -.amgengr.com EGRESS PLAT') <br /> ORIGINAL THIS DILMTNG SHML NOT BE <br /> 2525 E Burnside St.Portland,OR 97214 USED IN A MANNER THAT WOULD BE A i ISSUED FOR PERMIT Jow 3 19 19 I <br /> DRAWN BY r cnx0 Br DALE SCALE owc.xo. REV. <br /> DETRIMENT ro SMG.ACCEPTANCE OF THIS <br /> Phone:503.226.3617 DRAMNs IS AN AGREEMENT TO THE ARDYE. 0 ISSUED FOR CUSTOMER FINAL REVIEW J7w 2 11 19 J.P.WALL.AGE 19 AS NOTED 18-181A-18 1 <br /> Digitally signetl by Peter Gdmm SOM, REVISIONS BY DATE <br />