Laserfiche WebLink
Frame Member Schedule <br /> Frame Clearances <br /> Part Mem Width Thick WebThk. Depthl Depth2 Approx.Lgth Approx.Weight Horiz. Clearance between members 1 (CX003) and ll (CX004) : 112'-4 15/16" <br /> CX003 1 12.0000 .5000 .1875 1'-0" 3'-1" 29'-3 7/8" 2326# Horiz. Clearance between members 1 (CX003) and 12 (CX004) : 112'-5" <br /> 2 12.0000 .7500 .1875 3'-1" 3'-1" Horiz. Clearance between members 2 (CX003) and 11 (CX004) : 112'-4 15/16" <br /> RBX005 3 8.0000 .6250 .2500 4'-4" 2'-10" 21'-9 3/16" 1416# Horiz. Clearance between members 2 (CX003) and 12 (CX004) : 112'-4 15/16" <br /> 4 8.0000 .5000 .1875 2'-10" 2'-1" Vert. Clearance at member 2 (CX003) : 25'-0 9/16" <br /> RBX006 5 6.0000 .5000 .1644 2'-1" 2'-1" 35'-0" 1555# Vert. Clearance at member 11 (CX004) : 25'-0 9/16" <br /> 6 6.0000 .6250 .1875 2'-1" 3'-4" Finished Floor Elevation = 100'-0" (Unless Noted Otherwise) <br /> RBX007 7 6.0000 .6250 .1875 3'-4" 2'-1" 35'-0" 1563# <br /> OBolt Connection & Plate Schedule <br /> 8 6.0000 .5000 .1644 2'-1" 2'-1" Id Qty Grade Bolt Bolt Plate Rows Rows Tension Washer PartNo <br /> RBX008 9 8.0000 .5000 .1875 2'-1" 2'-10" 21'-9 3/16" 1433# <br /> Dia. Length Thick. Out In Bolt <br /> 10 8.0000 .6250 .2500 2'-10" 4'-4" A 12 F1852 7/8" 3" 3/4" 4 2 Yes Yes 0097397 <br /> CX004 11 12.0000 .7500 .1875 3'-1" 3'-1" 29'-1 1/4" 2326# B 10 F1852 3/4" 2 1/4" 1/2" 3 2 Yes Yes 0097389 <br /> 12 12.0000 .5000 .1875 1'-0" 3'-1" C 12 F1852 3/4" 2 1/2" 5/8" 2 4 Yes Yes 0097390 <br /> B p� <br /> 60'-2 1/2" 1.000:12 2 2 60'-2 1/2„ <br /> 1.000:12 <br /> n 10 @ 5'-0" 10 @ 5'-0„ <br /> 4'-9 15/16" 4'9 15/16„ <br /> o rH c-I <br /> un I` CD <br /> prj to CD O O O d� O N CDOL � <br /> O CD l� CD CD o � fA (� G' O CD14 O O Ol <br /> u7 M O O O M N� Ga pq fh O N Pq <br /> C Ln <br /> CDGq W PO PO �' -__Ch__ C77 C7-- -- W P7 PG w PQ PEI <br /> rn <br /> RBX007 'I <br /> I A RBX006 A <br /> I <br /> I RBX008 I <br /> RBXp05 <br /> I � I <br /> I � I <br /> o I <br /> o I a I <br /> � I I <br /> I I <br /> � I I <br /> N I I <br /> I I <br /> I I <br /> I o <br /> I � I <br /> I I <br /> I I <br /> I I <br /> 100'-1" 100'-1" <br /> I I I I q <br /> - 'K W <br /> 1 wfS <br /> 120'-0" �v�0l <br /> BL BL <br /> FRAME CROSS SECTION AT FRAME LINE (S) 2 <br /> 56 92 <br /> 4 34'-10" Ridge Ht. CISTE <br /> �ss./ouA`t� <br /> 3 3'-9 7/8" n 4 <br /> 2 1'-6 11/16"1 $ 1/2" 04/08/2019 <br /> [:] Dimension Key PERMIT SET-For Building e <br /> Shape Name=Cadman 1 Wall 4 Frame 2 g Dept.Approval <br /> THE VP ENGINEER'S SEAL APPLIES ONLY THIS DRAWING,INCLUDING THE INFORMATION HEREON,REMAINS THE PROPERTY OF <br /> 1.USE 1/2 X 1 1/2 A325T BOLT(49080)AND NUT(47120) TO THE WORK PRODUCT OF VP AND VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBEDBI <br /> VP Buildings <br /> W/O WASHERS.SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS, DESIGN AND PERFORMANCE IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT 3200 Players Club Circle Memphis TN 38125 FRAME CROSS SECTION AT FRAME LINE(S) 2 <br /> SECONDARY CLIP CONNECTIONS,AND FLANGE BRACE CONNECTIONS, REQUIREMENTS SPECIFIED BY VP. THE PURPOSE. IT SHALL NOT BE MODIFIED,REPRODUCED OR USED FOR ANY OTHER <br /> UNLESS NOTED OTHERWISE, VP ENGINEER'S SEAL DOES NOT APPLY PURPOSE WITHOUT PRIOR WRITTEN APPROVAL QF VP BUILDINGS. REV DATE By DESCRIPTION BULDER CHG Building Systems,Inc. JOB N <br /> 2.SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME TO THE PERFORMANCE OR DESIGN OF THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE CUSTOMER 18-040734 <br /> Cadman DATE <br /> SIDE OF THE WEB AS THE HILLSIDE WASHER ANY OTHER PRODUCT OR COMPONENT GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS LOCATION 4.5.2019 <br /> FURNISHED BY VP EXCEPT TO ANY DRAWING,DETAILS REFERENCED IN THIS DRAWING,ALL APPLICABLE VP BUILDINGS Everett,Washington �gn <br /> PROJECT DRAWWCHECK <br /> DESIGN OR PERFORMANCE ERECTION GUIDES,AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, Cadman Everett Bldg 1 Jac <br /> REQUIREMENTS SPECIFIED BY VP. INCLUDING THE CORRECT USE OF TEMPORARY BRACING. NITS BULOERs POI 28103 vac vERsbN: 2018.2b PAGE7 <br /> 4/4/2019 16:46:57 FLENAME:Cadman 1 a dNW f BI.S.pa Wldhg.North Am rlca,No. <br />