My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
17 E MARINE VIEW DR 2019 Plans 2025-09-29 (3)
>
Address Records
>
E MARINE VIEW DR
>
17
>
Plans
>
17 E MARINE VIEW DR 2019 Plans 2025-09-29 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2025 2:02:10 PM
Creation date
9/29/2025 1:59:55 PM
Metadata
Fields
Template:
Address Document
Street Name
E MARINE VIEW DR
Street Number
17
Permit
B1904-035
Year
2019
Notes
SOIL REMEDIATION RECYCLING FACILITY BY CADMAN
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Z-PURLIN Z-PURLIN Z-PURLIN GENERAL NOTES <br /> CONNECTION TO PUR IN 1. CONCENTRATED LOADS GREATER THAN 5001bs ON ANY SINGLE PURLIN MUST BE EXPLICITLY LOCATED AND DESIGNED <br /> (NOT BY BLUESCOPE� QONNECTION TO PUR IN FOR DURING DESIGN OF BUILDING SYSTEM. <br /> ANGLE HANGER (NOT BY BLUESCOPE� <br /> ONNECl10N TO PUR I <br /> NOT BY BLUESCOPE� 2. SPECIFIED COLLATERAL GADS MAY BE CONVERTED TO SAFE CO CENTRATED LOADS AS FOLLOWS, WHERE P = MAX <br /> CONCEN ATED LOAD Ibs W = UNIFORM COLLATERAL LOAD (PSF) x PURLIN SPACING (ft) = Ibs/ft; L = PURLIN <br /> HANGER LOAD I ENT PLATE OR STRAP SPAN (ft).. HANGERS �H OLD BE SPACED APPROX. EQUAL <br /> HANGER LQAD HANGER TLOY BLUESCOPE) IP r 1 P P lP I P <br /> P MAXi= 0.5w1 P M1AX= 0.4wl P MAX= 0.25WI <br /> WEB HANGERS <br /> FOR 1/2" DIAM. BOLT TO PURLIN CONNECTION-- MAX HANGER LOAD=15001bs <br /> PURLIN MUST BE SPECIFICALLY DESIGNED FOR LOADS GREATER THAN 500 LB. SEE NOTE #2. `P 1P IP I 1P I 1P IP IP 6 OR MORE HANGERS PER PURLIN <br /> i i i P MAX= W x HANGER SPACING <br /> P MAX= 0.2w1 P MAX= 0.15w1 <br /> WIDE THROAT BEAM EXAMPLE: A PIPE IS SUSPENDED FROM A PURLIN AT 3 LOCATIONS EQUALLY SPACED <br /> BE CLAMP MUST NOT BAY SPACING = 24'-0" PURLIN SPACING = 6-0-- <br /> PURLIN OR CONTACT <br /> PURLIN LIP NOT Z-PURLIN SPECIFIED COLLATERAL LOAD = 5 PSF <br /> BY BLUESCOPE) HALF FLANGE W = 5 PSF x 5 FT = 25 PLF L = 24'-0" <br /> WIDTH HALF FLANGE PMAX - 0.25 x 25 PLF x 24'-0" - 150 LEIS AT EACH LOCATION <br /> WIDTH THE PURLIN CAN SUPPORT 3 LOADS UP TO 150 LBS EACH. PICK A HANGER CONNECTION <br /> Z- PURLIN FIELD DRILL HOLE CAPABLE OF SUPPORTING ACTUAL APPLIED LOADS. <br /> DO NOT USE A HANGER DEVICE FOR ROD IN <br /> PURLIN M <br /> AT CAUSES DEFORMATION ANGER ROD (7/118- MAX HOLE) 3. FOR LOADS GREATER THAN 250 Ibs, PURLINS MUST BE "BLOCKED" AT LOCATION OF LOAD TO PREVENT PURLIN ROTATION. <br /> (FLATTENING) OF THIS FLANGE LIP NOT BY <br /> ULUESCOPE) 4. EQUIPMENT LOADS SHOULD BE OBTAINED FROM CERTIFIED EQUIPMENT DRAWINGS AND MANUFACTURER'S DATA. <br /> VERIFY OVERALL PURLIN DESIGN CAN TAKE APPLIED LOADS. SEE NOTE #2 5. Z-PURLINS WILL DEFLECT UNDER SNOW AND WIND LOADS. ITEMS THAT MAY BE DAMAGED DUE TO DEFLECTIONS, (EX. GAS <br /> MAXIMUM LOAD SUSPENDED FROM BOTTOM FLANGE LINES), VERIFY THAT PIPES OR SUSPENDED EQUIPMENT ARE COMPATIBLE WITH EXPECTED DEFLECTION RANGES (±-L/180). <br /> (LOCATED AT HALF-FLANGE WIDTH) 6. THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) REQUIRES SPRINKLER HANGERS TO BE DESIGNED FOR A <br /> MINIMUM LOAD OF FIVE TIMES THE WEIGHT OF THE wWATER-FILLED PIPE PLUS 250 POUNDS, THE HANGER ITSELF MUST <br /> BE ABLE TO SUPPORT THIS LOADING IT IS NOT NECESSARY TO DESIGN THE SUPPORTING MEMBER FOR THIS LOAD IN <br /> THICKNESS MAX LOAD THICKNESS MAX LOAD COMBINATION WITH THE DESIGN LOADS. <br /> 0.060" 110Ibs 0.08B" 2001bs 7. SUSPENDED LOADS WALL NEED TO BE BRACED (TO THE PRIMARY FORCE RESISTING SYSTEM) FOR LATERAL STABILITY DUE <br /> 0.0813" 1201bs TO EARTHQUAKES. <br /> 0.073" 1401be 0.09B" 2501bs B. HANGER DESIGN IS NOT THE RESPONSIBILITY OF BLUESCOPE. <br /> 0,079" 1801bs 0.113" 2501bs 9. TOP FLANGE,H IF TOP FLANGE BE GERSDAREOREQUIREID�PLACE THE(HANGERS ATT SPACER <br /> PANEL MAJOR CORRUGATION <br /> FOR LOADS LOCATED MORE THAN HALF FLANGE WIDTH LOCATION TO AVOID DAMAGING THE ROOF PANEL WITH THE HANGER WHEN THE ROOF PANEL IS LOADED OR WALKED ON. <br /> FROM WEB, USE HALF OF THE LOADS SHOWN ABOVE 10. WHEN BEAM C-CLAMPS OR OTHER ROD HANGERS ARE USED ON THE TOP FLANGE THE ROD SHOULD NOT EXTEND ABOVE <br /> THE TOP OF THE CLAMP TO AVOID DAMAGING THE ROOF PANEL WITH THE ROD VAEN THE ROOF PANEL IS LOADED OR <br /> WALKED ON. <br /> BOTTOM FLANGE CLAMP HANGER BOTTOM FLANGE ROD HANGER <br /> (TOP FLANGE SIMILAR) (TOP FLANGE SIMILAR) 11. DO NOT HANG ANY TYPE OF CRANE, HOIST, CONVEYOR OR ANY MOVING LOADS FROM THE Z-PURLINS. <br /> DO NOT USE ANY OF THE DETAILS ABOVE IF ROOF SLOPE IS GREATER THAN +'12 12. DO NOT HANG ANY LOAD FROM BBNA SUPPLIED PURLIN BRACES OR BRIDGING. <br /> Z-PURLIN HANGER ASSEMBLY 13. DO NOT WELD ANY PART OF THE Z-PURLIN. <br /> Z-PURLIN (NOT BY BLUESCOPE) 14. HOLES MUST NOT EXCEED 9/1ti" DIAMETER UNLESS AUTHORIZED BY BBNA ENGINEER. DRILL OR REAM HOLES WHEN <br /> REQUIRED- DO NOT FLAME CUT <br /> R+ RI <br /> HALF FLANGE I HALF FLANGE <br /> Kww�s`�! <br /> h to <br /> N i <br /> R Mq� PER HANGER ASSEMBLYorsr�co �{r <br /> TABLE ABOVE FOR (NOT BY BLUESCOPE) ONAL <br /> EACH PURLIN <br /> HANGER LOAD !HANGER LOAD o4i09i2019 <br /> PG. 35 <br /> DOUBLE PURLIN HANGERS CONCENTRATED LOADS ON ROOF <br /> Z—PURLIN HANGER DETAILS <br /> VERIFY OVERALL PURLIN DESIGN CAN SUPPORT APPLIED LOADS. mAv" GROUP NUNma W-054-01 <br /> REVERITT RBENTON <br /> "'�"°L`z°"'� B I B-081465 07 <br /> 02 26 1D 1 11 13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.