5. PROVIDE PROPERLY SIZED WASHERS UNDER HEADS AND NUTS OF ALL 9. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING <br /> BUILDING CODE BOLTS AND LAG SCREWS BEARING ON WOOD. CONDITIONS 15 GIVEN AS THE BEST PRESENT KNOWLEDGE, BUT WITHOUT IDA <br /> 2010 INTERNATIONAL BUILDING CODE GUARANTEE OF ACCURACY. WHERE ACTUAL CONDITIONS CONFLICT WITH <br /> G. PROVIDE 3"x3"xO.229" WASHERS AT ALL ANCHOR BOLTS. THE DRAWINGS, THEY SHALL BE REPORTED TO THE ENGINEER 50 THE <br /> FLOOR LOAD PROPER REVISIONS MAYBE MADE. MODIFICATIONS TO CONSTRUCTION <br /> 7. BOLT HOLES SHALL BE NOMINAL DIAMETER OF BOLT PLUS I # I G" UNLESS DETAILS SHALL NOT BE MADE WITHOUT PRIOR WRITTEN APPROVAL BY THE <br /> DEAD LOAD : 12 psf NOTED OTHERWISE. LAG BOLT PILOT HOLES SHALL BE PRE-DRILLED TO GO% ENGINEER. <br /> LIVE LOAD: 40 psf RESIDENTIAL OF THE NOMINAL DIAMETER OF THE LAG BOLT UNLESS NOTED OTHERWISE. SIMPSON ECCQ, U.N.O. <br /> 4 o <br /> ROOF LOAD 8. ALL SILL PLATES SHALL BE BOLTED TO THE FOUNDATION WITH 5#8" o <br /> DEAD LOAD: 15 psf MINIMUM DIAMETER BOLTS SPACED AT A MAXIMUM OF 48" ON CENTER. .p <br /> FLAT ROOF SNOW LOAD: 25 psf BOLTS MUST BE EMBEDDED A MINIMUM OF 7" INTO CONCRETE OR V N <br /> SNOW EXPOSURE FACTOR (Cc): I . I MASONRY. SEE PLANS AND DETAILS FOR SPECIFIC REQUIREMENTS WHERE Q �M 0 <br /> SNOW LOAD IMPORTANCE FACTOR (Is): 1 .0 APPLICABLE. a i r <br /> THERMAL FACTOR (Ct): I . I I •C Y C <br /> BEAM PER PLAN <br /> 9. RIM JOIST IS TO BE 14' L5L MINIMUM. POST PER PLAN Cn o a <br /> WIND DE51GN DATA <br /> I . BASIC WIND SPEED: 1 10 MPH 10. PROVIDE DOUBLE JOIST UNDER ALL PARALLEL PARTITION WALLS AND <br /> 2. WIND IMPORTANCE FACTOR (IM: 1 .0 SOLID BLOCKING UNDER PERPENDICULAR PARTITION WALLS. POST/BEAM (ONE SIDE) M E <br /> BUILDING CATEGORY: II w' LO <br /> N <br /> 3. WIND EXPOSURE: B 1 1 . CONTACT THIS OFFICE PRIOR TO MAKING ANY CHANGES TO THESE <br /> 4. Kzt = I .G7 DETAILS o e U z <br /> 5. INTERNAL PRESSURE COEFFICIENT: NA e i o a <br /> G. APPLICABLE WIND PRESSURE FOR GENERAL + <br /> COMPONENTS AND CLADDING: NA (A <br /> 1 . ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE CONTRACT SIMPSON CCQ, U.N. BEAM PER PLAN <br /> 5E51MIC DESIGN DATA DRAWINGS. <br /> 1 . SEISMIC IMPORTANCE FACTOR: ) .0 POST PER PLAN <br /> SEISMIC USE GROUP: 1 2. DURING THE CONSTRUCTION PERIOD THE CONTRACTOR SHALL BE -- <br /> 2. SPECTRAL RESPONSE ACCELERATION (55): 1 1 5.9% G RESPONSIBLE FOR THE SAFETY OF THE BUILDING. THE CONTRACTOR SHALL POST/BEAM (TWO SIDES) <br /> 3. SITE CLASS: D (ASSUMED) PROVIDE ADEQUATE SHORING, BRACING AND GUYS IN ACCORDANCE WITH <br /> 4. SPECTRAL RESPONSE COEFFICIENTS (5D5): 80.4%G ALL NATIONAL, STATE AND LOCAL SAFETY ORDINANCES. ANY DEVIATION _-- <br /> 5. SEISMIC DESIGN CATEGORY: D MUST BE APPROVED PRIOR TO ERECTION. TYP . POST TO BEAM No. ooW By RwWW <br /> G. BASIC SEISMIC-FORCE-RESISTING SYSTEM: SHEARWALLS DCONN . <br /> 7. DESIGN BASE SHEAR: SEE CALCULATIONS 3. ALL ERECTION PROCEDURES SHALL CONFORM TO OSHA STANDARDS. <br /> 8. SEISMIC RESPONSE COEFFICIENT (Cs): 0.87 ANY DEVIATION MUST BE APPROVED BY OSHA PRIOR TO ERECTION. POST PER PLAN <br /> 9. RESPONSE MODIFICATION FACTOR (R): G.5 <br /> I O. ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL 4. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL -----�- <br /> FORCE PROCEDURE CONSTRUCTION PROCEDURES INCLUDING LAGGING, SHORING AND MPB44z POST BA _ <br /> PROTECTION OF ADJACENT PROPERTY, STRUCTURES, STREETS AND UTILITIES W W O <br /> IN ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL SAFETY f�0 Su(�T��u-rlo�s �, LL � N <br /> ORDINANCES. � <br /> 00 <br /> FRAMING LUMBER 12" 0 CONCRETE COLUMN � QW <br /> I . FRAMING LUMBER SHALL BE HEM-FIR NO. 2. GRADES 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE 6" MIN IZ I- Q <br /> ARE TYPICAL UNLESS OTHERWISE NOTED ON PLANS. }- <br /> WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS. ALL II I I I (8) #4 VERTS EQUALLY O <br /> LUMBER TO BE GRADE MARKED PER WCLIB DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE ENGINEER AND _ 0 <br /> SPECIFICATIONS. BE RESOLVED BEFORE PROCEEDING WITH THE WORK. 1 I-1II�11� SPACED w/ #3 TIES @ 3 = <br /> III,_ Ir-II . o/c,SQUARE & DIAGONALY <br /> 2. STRUCTURAL SHEATHING SHALL BE APA RATED (TYP) HOOK VERTICAL (n W <br /> PLYWOOD, EXPOSURE I SHEATHING CONFORMING TO 7. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. 18" MIN BARS INTO FOOTING AS Q N <br /> WHERE CONDITIONS ARE NOT 5PECIFICALLY INDICATED BUT ARE OF 5IMILAK SHOWN U 0 W <br /> EITHER COMMERCIAL STANDARDS P5 1 -83, APA PRP- 1 06, CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION � <br /> OR VOLUNTARY PRODUCT STANDARD P5E-92. PROVIDE A SHALL BE USED SUBJECT TO REVIEW BY THE ENGINEER. a a FOOTING AND � W <br /> MINIMUM OF 3/8" EDGE DISTANCE ON ALL NAILS AND /8" • REINFORCEMENT PER <br /> EXPANSION JOINT BETWEEN ALL PANEL EDGES. MINIMUM 8. ALL DETAILS DESIGNATED AS STANDARD OR TYPICAL SHALL OCCUR IN PLAN <br /> SHEATHING REQUIREMENTS ARE AS FOLLOWS: ADDITION TO ANY OTHER SPECIFIC DETAIL CALLED OUT. cov <br /> ROOF SHEATHING TO BE 15/32" INT-APA RATED TYPICAL CONCRETE PLINTH �� �pEWAsy�� <br /> PLYWOOD OR 7/6" OSB WITH EXTERIOR GLUE, P.I. 2 <br /> 24/0. NAIL WITH I Od NAILS AT G" ON CENTER AT vy- <br /> PANEL EDGES AND 1 2" ON CENTER AT INTERMEDIATE <br /> MEMBERS. <br /> 34 <br /> SUB FLOORING TO BE 3/4" TONGUE AND GROOVE C-D � <br /> INT-APA RATED PLYWOOD ORO5D WITH EXTERIOR STRUCTURAL SPECIAL INSPECTION SCHEDULE <br /> GLUE, P.I. 48/24. GLUE AND NAIL WITH I Od NAILS REFERENCE IBC MAR ".31 2022 <br /> AT G" ON CENTER AT PANEL EDGES AND 1 2" ON REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION CONTINUOUS PERIODIC STANDARD REFERENCE <br /> CENTER AT INTERMEDIATE MEMBERS. <br /> Inspection of reinforcing steel ACI 318: 3.5, 1908.5,1909.1 DRAWN BY: CCC <br /> 3. NAILING SHALL CONFORM TO TABLE 2304.9. 1 OF THE X 7 17_ 7.7 CHECKED BY. CCC <br /> DATE: 03/29/22 <br /> INTERNATIONAL BUILDING CODE UNLESS NOTED OTHERWISE. USE COMMON NAILS THROUGHOUT UNLESS Ispection of anchors installed in hardened concrete ACI 318: 3.8.6,8.1 .3, 1909.1 JOB N0. 9411 <br /> X NOTED OTHERWISE. 2128 <br /> STRUCTURAL WOOD STRUCTURAL <br /> 4. NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED Rquired for nailing bolting, anchoring and other fastening of elements of the <br /> UNLESS SPECIFICALLY DETAILED OR APPROVED IN WRITING lateral resisting system, including shearwalls, wood diaphragms, drag struts,ecial inspection is not required when the fastener X 1705.11 .1 , NOTES/DETAIL <br /> BY THE STRUCTURAL ENGINEER. braces and holdowns. S ins re <br /> P P q 1705.12.2 <br /> spacing of the sheathing is more than 4 inches on center. S-1.0 <br />