5- -2 _7`' <br /> UNIFORM PLUMBING GOEDE P�1 wM r <br /> 5YM FIXTURE TYPE 5EWER VENT GOLD HOT MIXED NO O W. FIXT. TOTAL W. DR. FIXT TOTAL DR. 04 <br /> WATER WATER kNATEfR FIXT. UNIT5/EA FIXT UNITE UNITS FIXT. UNITS O <br /> WC-1 ADA TOILET 3" 2" 1" X - 1 40,30,20,15,1 40 4 4 " t <br /> HB-1 WALL HYDRANT ANTI-FREEZE X X 3/4" X - 1 2.5 2.5 NA NA o w <br /> FD-1 I FLOOR DRAIN 1 3" 1 1/2" X X - 1 NA NA 2 2 �� R 1133 �� ?� <br /> TOTAL 42.5 TOTAL 6 "`"� n A►. �G <br /> GENERAL FLUMBINO NOTES: Ek. — -z3 <br /> WZ <br /> _ _ o <br /> 1. ALL PIPE ( WATER, SEINER, VENT), JOINTS, AND WORK SHALL CONFORM TO UNIFORM PLUMBING CODE, o <br /> STATE CODES, COUNTY AND LOCAL CODES AND ORDINANCES. u_ � _ <o <br /> 2. CONTRACTOR TO CONFIRM LOGATION5 OF 5EWER AND WATER TIE-INS. 0 Ea d d i E w A <br /> tam � oxa ao <br /> LU <br /> 5. CONTRACTOR TO 50LIDLY BRACE ALL PIPING TIGHT AGAINST WALLS. FOR LONG OR COMPLICATED Q z ao2 LL t o 2 <br /> RUNS, SECURELY MOUNT U5IN6 UNI-STRUT, IN 5TRAI6HT AND UNIFORM MANNER FOR FINISHED Q w <br /> APPEARANCE. PIPING SHOWN 15 DIAGRAMMATIC, ONLY AND ACTUAL DE516N BY CONTRACTOR. <br /> Q Z[ <br /> v w = <br /> 4. CONTRACTOR MAY CHANGE PIPE 51ZIN6 IN FIELD TO PROVIDE ADEQUATE WATER PRE55URE TO ALL <br /> W U �a <br /> PLUMBING FIXTURES AS APPROVED BY INSPECTOR. ROMTEG BUILDINGS ARE DESIGNED) TO HAVE N <br /> 40-60 P51 RATER PRESSURE FOR THE PLUMBING FIXTURES. IF THE SITE HAS A PRESSURE OTHER THAN w w <br /> THIS, IT 15 THE OWNER'S RESPONSIBILITY TO PROVIDE THE PRE55URE REDUCER OR BOOSTER PUMP a "l <br /> NECESSARY. m o <br /> O � <br /> 5. CONTRACTOR TO DETERMINE AND PROVIDE MEANS FOR GRAVITY DRAINING ALL PLUMBING FIXTURES z 0 <br /> TO SEPTIC OR SANITARY SEWER SYSTEM. INSTALLER TO PROVIDE A GLEAN-OUT BENEATH ALL SINKS <br /> AND LAVATORY AS REQUIRED BY CODE. <br /> 6. CONTRACTOR TO DETERMINE AND PROVIDE MEANS FOR SUPPLYING WATER TO ALL PLUMBING A O <br /> FIXTURES AND INSTALL WATER SERVICE SHUTOFF VALVE; TYPICALLY LOCATED WITHIN THE MECHANICAL w O <br /> ROOM. Q IS) <br /> 7. IF THE 51TE REaUIRE5 AN ACCESSIBLE BACK FLOW PREVENTER AND/OR PRE55URE REDUCER OR 3: ts) Lu <br /> Lu <br /> B005TER PUMP IT 15 THE OWNER'S RESPONSIBILITY TO PROVIDE. Q 0 Q <br /> 8. WHEN INCLUDED WATER TANKS REQUIRE A PRESSURE RELIEF VALVE AND A DRAIN LINE TO THE ID v- J <br /> EXTERIOR OF THE BUILDING PER 2009 UPC SECTIONS (508.4 B 6055. CONTRACTOR TO PROVIDE AND = n Z 0) <br /> INSTALL TWO STRAPS TO THE NEAREST WALL, ONE STRAP AT TOP 1/3 OF TANK AND ONE STRAP AT ~ _ <br /> BOTTOM 1/5 OF TANK, IN COMPLIANCE WITH 2O09 UPC SECTION 505.2. Ll z W ts) Z <br /> Q [0 <br /> 9. FLU5HOMETER5 ASSOCIATED WITH TOILETS USE NO MORE THAN 1.6 6ALLON5 PER FLUSH. 0 m <br /> FLU5HOMETER5 ASSOCIATED WITH URINALS USE NO MORE THAN 1.0 6ALLON PER FLUSH. BOTH OF THE: Q <br /> ABOVE SHALL MEET PERFORMANCE STANDARDS BY AN51 A112.1ci.2 H$5 CODE, SECTION 17921.3(b) _ W W w <br /> 10. WHEN FIXTURES REQUIRE WALL CARRIERS THE WALL CARRIER SHALL BE SUPPLIED BY CONTRACTOR. z W W W <br /> � Q ° wW = <br /> 11. UNLE55 SPEGIFIEI7 IN THE ROMTEC SUBMITTAL, ROMTEG DOES NOT SUPPLY INSULATION OR "FREEZE ro PLAN SET# N <br /> PROTECTION" FOR PLUMBING. "THE OWNER MAY NEED TO WINTERIZE THEIR BUILDING." ki z � E5R01 <br /> Q DATE: <br /> z 05/25/2023 <br /> REVISIONS <br /> QREV. I DATE: IBY <br /> 1-p4-26-20231 CR <br /> m <br /> O � <br /> N � oaAwN Bv: <br /> OO Q GR <br /> SHEET NO. <br /> �1 <br /> JOB CREATED:5/1/2023-LA57 SAVED BY:Gruport ON 5/1/2023-LAST PRINTED:5/1/2023-LOCATION:ONEngineering RNPlan Sets\E5R01-Everett Sidewalk^A\ESR01-Everett Sidewalk 4001,WA-230501.dwg <br />