My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2609 HOYT AVE 2022 Plans 2025-09-30
>
Address Records
>
HOYT AVE
>
2609
>
Plans
>
2609 HOYT AVE 2022 Plans 2025-09-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/30/2025 8:49:03 AM
Creation date
9/30/2025 8:48:12 AM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
2609
Permit
B2212-050
Year
2022
Notes
REPLACE EXISTING DECK WITH NEW 18'8" X 11''4" DECK
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CL Co. <br /> W <br /> 0 !EW.... W~ OW(7 <br /> >Z >- <br /> � ¢o¢E�rc�oO> mFy <br /> Z OmwW�-�ZZ�-Z< <br /> - � UOwOyU ipp=x„o¢ <br /> N ¢>jO FN�sj U¢m 0m,-z <br /> N W O�OW 4¢KpN2W¢ <br /> cI= a¢�000Zp0 OR <br /> ,wZ C� UKF In UN WwUK <br /> MyBuildingPermitxom MyBuildingPermit.com �¢ w=�w=��ow0 <br /> o �wir�N�a�wo=�� <br /> ❑ w¢rcOwO-N <br /> a service of eCityGov.net Construction Tip Sheet 05 a service of eCityGov.net Construction Tip Sheet 05 M o R—fi . <br /> u � <br /> Deck Ledger and Connections <br /> Deck Ledger Connection to Band Joist EXTERIOR SHEATHING—� <br /> On-Center Spacing of Fasteners inches EXISTING STJD WALL�� CD <br /> Joist Span c '/2-inch diameter lag '/z-inch diameter bolt '/2-inch diameter bolt Existing 2,BAND JOIST b <br /> (feet) screw with '/z-inch with 1/2-inch screw with 1-inch OR ENGINEERING RIM C. <br /> BOARD � .� <br /> maximum sheathin b,c,e maximum sheathing c maximum sheathingd <br /> 6 22 36 35 —DECK JOIST <br /> I I l ) U) I EL <br /> 8 16 31 26 s'•'�` v <br /> SCRE:,S OR BOLTS <br /> 10 13 25 21 —- <br /> 12 11 20 17 <br /> 14 9 17 15 <br /> 16 8 15 13 -31` •-HANG_ o <br /> 00 <br /> 18 7 13 11 <br /> a. Ledgers shall be flashed in accordance with Section R703.4 to prevent water from 3 <br /> contacting the house band joist. r-Lag screw or bolt Stagger fasteners in 2 rows U <br /> b. The tip of the lag screw shall fully extend beyond the inside face of the band joist. 2"m n. <br /> c. Sheathing shall be wood structural panel or solid sawn lumber. J/ 5 112"min.for 2x8- <br /> 6 112"min.for 2x10 r. <br /> d. Sheathing shall be permitted to be wood structural panel, gypsum board,fiberboard, 5"max. 1�71? 7 1/2"min.for 2x12 <br /> lumber, or foam sheathing. Up to 1/2-inch thickness of stacked washers shall be permitted to sCN <br /> substitute for up to 1/2-inch of allowable sheathing thickness where combined with wood 3/4"min. N <br /> Ledger Distance can be reduced to <br /> structural panel or lumber sheathing. /-/-2"min. 4 112"if lag screws are used or <br /> e. For on-center spacing of specialized fasteners refer to the manufacturer's installation Minimum edge distance for if bolt spacing is reduced to <br /> Instructions. specialized screws.See that of lag screws to attach 2x8 b <br /> manufacturer's technical bulletin. ledgers to 2x8 band joists 1.4 <br /> Placement of Lag Screws and Bolts in Ledgers and Band Joists <br /> Minimum End and Edge Distance and Spacing Between Rows Detail 1 - Ledger Attachment for Lateral Loads o <br /> (Knee oraces are regwreo on posts greater than 4'eet in heignt.l ® c <br /> 00 <br /> Top Edge Bottom Edge Ends Row Spacing ® z <br /> Ledger' 2 inches d 3/4 inch 2 inches b 1-5/8 inches b 1��e sneStdding <br /> Band joist` 3/4 inch 2 inches e 2 inches b 1-5/8 inches b 1r with 1s00: �" o <br /> 1 ` cap,K� Flowsheauwngnagw�q Flashing <br /> 1} s16'oc I max)lofoist 1� <br /> rinth hold-down Decking q <br /> a. Lag screws or bolts must be staggered from the top and bottom along the horizontal run. Flashing_ ® s <br /> See figure below. Joists - <br /> b. Maximum 5 inches. Joist Hangers IZ <br /> c. For engineered rim joists, the manufacturer's recommendations govern. >W-07iv -- Treated 2x ledger X - 2 <br /> d. The minimum distance from the bottom row to the top edge of the ledger must be in l`1"'- - r "1-J N <br /> accordance with figure below. �_, ,,.,._ `-" / = <br /> —P'oor,o,st 7501'caoac;t holddown devCe J <br /> e. 2 inches may be reduced to 3/4-inch when the band joist is directly supported by a y &, x <br /> at 4 locations evenly distribut =r joists a 5C m <br /> mudsill, header, or by double top wall plates. along the deck and within 2 n or <br /> each and Instal,per manufacturer �/ u <br /> C N <br /> u � w <br /> Fully threaded"'diameter lag Screw <br /> Option # 1 <br /> p Wedn led with a minimum of a in Option # 2 >x <br /> embedment Into sold framing 6 r C <br /> January 14,2022 MyBuildingPermit.com I Basic Deck January 14,2022 MyBuildingPermit.com I Basic Deck vt rQ" c <br /> , J <br /> O > <br /> r o <br /> Q Qn N� 5 C..o <br /> C tvcov-letCityGovnet <br /> Date Nov,19th,2022 <br /> Sheet <br /> C3 <br /> a <br />
The URL can be used to link to this page