Laserfiche WebLink
rrerrnfLH: DL UJ-Voi <br /> BUILDING CODE Site Address: 3407 GRAND AVE: <br /> 2018 INTERNATIONAL BUILDING CODE Owner: CHEEVER EMILY A&CURT <br /> FLOOR LOAD App.Date: 5/30/2023 <br /> DEAD LOAD 12 psf LIVE LOAD: 40 psf Permit Type: RESIDENTIAL BUILDING <br /> ROOF LOAD Subtype: RESIDENTIAL ALTERATION(REMODEL) <br /> DEAD LOAD: 15 psf Description: KITCHEN&LIVING RM REMODEL REMOVE <br /> FLAT ROOF SNOW LOAD: 25 psf <br /> SNOW EXPOSURE FACTOR (Ce): 1.1 WALL, NEW BEAM&WINDOWS <br /> SNOW LOAD IMPORTANCE FACTOR (Is): 1.0 <br /> THERMAL FACTOR (Ct): 1.1 Reviewed By: <br /> FOUNDATIONS _L-Office Set Job Site set <br /> 1. THE FOUNDATION DESIGN IS BASED ON THE RECOMMENDATION IN THE INTERNATIONAL BUILDING CODE TABLE 1804.2. FOUNDATION 4' <br /> WORK SHALL BE PERFORMED IN ACCORDANCE WITH CHAPTER 18 OF THIS CODE. 0 <br /> This property is deemed historic and subjec 6 <br /> 2. 'THE FOUNDATION DESIGN IS BASED ON THE FOLLOWING VALUES: to special regulations.Any changes to approve rn <br /> ALLOW. SOIL BEARING = 1500 PSF rn M <br /> SOIL FRICTION = .25 plans shall be reviewed by Planning. Contac Q a N 8 <br /> EQUIV. FLUID PRESSURES: ¢- <br /> *ACTIVE PRESSURE = 35 PCF w°i <br /> PASSIVE PRESSURE = 150 PCF <br /> *(WALLS RESTRAINED AGAINST ROTATION SHALL BE DESIGNED FOR AN EQUIV. FLUID VKL55UKL Ur- ).M PLP 425-257- �"`� � n r�a <br /> 3. ALL FOOTINGS SHALL BE FOUNDED AT LEAST 18" BELOW THE UNDISTURBED GROUND SURFACE OR TO FROST DEPTH. ALL FOOTINGS C a d a]m. <br /> SHALL BE FOUNDED ON COMPACTED FILL OR UNDISTURBED NATURAL GRADE UNLESS OTHERWISE NOTED. M w=; <br /> a; <br /> 4. COMPACTION: MATERIAL FOR FILLING AND BACKFILLING SHALL CONSIST OF THE EXCAVATED MATERIAL AND/OR IMPORTED BORROW AND <br /> SHALL BE FREE OF ORGANIC MATTER, TRASH, LUMBER, OR OTHER DEBRIS. ALL WALLS SHALL BE ADEQUATELY BRACED PRIOR TO +� <br /> BACKFILLING. FILL AND BACKFILL SHALL BE DEPOSITED IN LAYERS NOT TO EXCEED 8 INCHES THICK, PROPERLY MOISTENED TO U <br /> APPROXIMATE OPTIMUM REQUIREMENTS AND THOROUGHLY ROLLED OR COMPACTED WITH APPROVED EQUIPMENT IN SUCH A MANNER AND <br /> EXTENT AS TO PRODUCE A RELATIVE COMPACTION OF 90% OF MAXIMUM POSSIBLE DENSITY AS DETERMINED BY ASTM D1557. HAND <br /> TAMPERS SHALL WEIGH AT LEAST 50 POUNDS EACH AND SHALL HAVE A FACE AREA NOT IN EXCESS OF 64 SQUARE INCHES. HAND /r� <br /> TAMPERS MAY BE OPERATED EITHER MANUALLY OR MECHANICALLY AND SHALL BE USED WHERE LARGER POWER DRIVEN COMPACTION <br /> EQUIPMENT CANNOT BE USED. FILL OVER 12" DEEP SHALL COMPLY WITH A GEOTECHNICAL REPORT. <br /> GLUED-LAMINATED TIMBER <br /> 1. ADHESIVE SHALL BE FOR WET USE. �_", '�. t.l > <br /> 2. LAMINATIONS SHALL BE OF DOUGLAS FIR/WESTERN LARCH, COMBINATION 24F-V4 FOR SIMPLE SPAN BEAMS AND 24F-V8 FOR v <br /> CONTINUOUS MULTIPLE SPAN AND CANTILEVERED BEAMS, FABRICATED IN ACCORDANCE WITH AITC A190.1 AND ASTM D 3737. <br /> m; <br /> 3. FABRICATION SHALL BE BY A LICENSED FABRICATOR; SHOP DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR a <br /> TO FABRICATION. AITC CERTIFICATES OF INSPECTION ARE REQUIRED FOR ALL MEMBERS. ro I .,7 <br /> c .ml r!rl <br /> 4. GLULAM BEAMS EXPOSED TO WEATHER SHALL BE WOLMANIZED OR PRESSURE TREATED. p tll <br /> FRAMING LUMBERICL <br /> cZ. .. <br /> 1. FRAMING LUMBER SHALL BE DOUGLAS FIR/LARCH NO.1 FOR POSTS, BEAMS, AND HEADERS; HEM-FIR NO.2 FOR 2X AND 3X JOISTS, AND <br /> STUDS; AND HEM-FIR NO.2 FOR ALL TOP AND BOTTOM PLATES (GRADES ARE TYPICAL UNLESS OTHERWISE NOTED ON PLANS). LUMBER �- <br /> TO BE GRADE MARKED PER WCLIB SPECIFICATIONS. <br /> 2. STRUCTURAL SHEATHING SHALL BE APA RATED PLYWOOD, EXPOSURE 1 SHEATHING CONFORMING TO EITHER COMMERCIAL STANDARDS <br /> DOC PS 1 OR PS 2. PROVIDE MINIMUM OF 3/8" EDGE DISTANCE ON ALL NAILS AND A 1/8" EXPANSION JOINT BETWEEN ALL PANEL <br /> EDGES. MINIMUM SHEATHING REQUIREMENTS ARE AS FOLLOWS: ["'I <br /> ROOF SHEATHING TO BE 15/32" C-D INT-APA RATED PLYWOOD WITH EXTERIOR GLUE, P.I. 24/16 (USE 5-PLY FOR PANELIZED ¢m W (D <br /> ROOFS). NAIL WITH 8d NAILS AT 6" ON CENTER AT PANEL EDGES AND 12" ON CENTER AT INTERMEDIATE SUPPORTS UNLESS 'p¢ W.0 <br /> NOTED OTHERWISE. RZ 3 <br /> SUB FLOORING TO BE 3/4" T&G C-D INT-APA RATED PLYWOOD WITH EXTERIOR GLUE, P.I. 48/24. GLUE AND NAIL WITH 10d (�� W co <br /> NAILS AT 6" ON CENTER AT PANEL EDGES AND 12" ON CENTER AT INTERMEDIATE SUPPORTS UNLESS NOTED OTHERWISE. Iri:br-UJ <br /> �w �1= <br /> 3. NAILING SHALL CONFORM TO TABLE 2304.10.1 OF THE INTERNATIONAL BUILDING CODE UNLESS NOTED OTHERWISE. USE COMMON NAILS �i w O E <br /> THROUGHOUT UNLESS NOTED OTHERWISE. <br /> 4. NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS SPECIFICALLY DETAILED OR APPROVED IN WRITING BY THE STRUCTURAL U a <br /> ENGINEER. <br /> F�1 <br /> 5. USE DOUBLE JOISTS UNDER WALLS OR PARTITIONS PARALLEL TO JOISTS UNLESS SPECIFICALLT;H685 DOCUMENTS @ NOT B V <br /> BLOCKING UNDER PARTITIONS PERPENDICULAR TO JOISTS. APPROVED FOR THE ISSUANCE OF <br /> 6. RIM JOIST ARE 1YV LSL OR 2x SOLID SAWN LUMBER AS MINIMUM. PUBLIC WORKS, MECHANICAL, FIRE `�°'"° <br /> 7. MAXIMUM MOISTURE CONTENT SHALL NOT EXCEED 16% FOR ALL STRUCTURAL MEMBERS. SUPPRESSION, ELECTRICAL OR <br /> PLUMBING PERMITS, '' <br /> 8. PROVIDE 2X2 WASHERS UNDER HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. <br /> 9. BOLT HOLES SHALL BE NOMINAL DIAMETER OF BOLT PLUS 1/16" UNLESS OTHERWISE NOTED. LAG BOLT PILOT HOLES SHALL BE FEB 09, 2023 <br /> PRE-DRILLED TO 60% OF THE NOMINAL DIAMETER OF THE LAG BOLT UNLESS OTHERWISE NOTED. <br /> 10. ALL SILL PLATES SHALL BE BOLTED TO THE FOUNDATION WITH 5/8" MINIMUM DIAMETER BOLTS SPACED AT 48" O.C. MAXIMUM Drawn By. CRL <br /> SPACING (EMBED 7" MINIMUM INTO CONCRETE OR MASONRY). SEE PLANS AND DETAILS FOR SPECIFIC REQUIREMENTS WHERE OCCUR. Checked CCC <br /> Date: 02-0808-2023 <br /> 11. ALL FRAMING LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED. (SEE NOTE 1 FOR MINIMUM GRADE SDA JOB No. <br /> INFORMATION). ALL FOUNDATION BOLTS AND CONNECTORS MUST BE HEAVY GALVANIZED, OR Z-MAX COATING TO PROTECT FROM g 5 2 <br /> OXIDATION. <br /> 12. FIELD-CUT ENDS, NOTCHES, AND DRILLED HOLES OF PRESSURE PRESERVATIVE TREATED WOOD SHALL BE RETREATED IN THE FIELD IN <br /> ACCORDANCE WITH AWPA M4. IRC 317.1.1 STRUCTURAL <br /> 13. 2X4 RAFTERS EXCEPT WHERE SPECIFICALLY DETAILED SHALL NOT SUPPORT SUSPENDED CEILINGS, SPRINKLERS, DROP SOFFITS, OR ANY NOTES <br /> OTHER ELEMENTS. <br /> S- 'O <br /> 14, WIRE STAPLES MAY BE SUBSTITUTED FOR DIAPHRAGM AND SHEARWALL NAILING WHEN APPROVED BY THE STRUCTURAL ENGINEER. <br />