Laserfiche WebLink
Permit#: FA2201-003 <br /> Site Address: 1001N BROAOW <br /> AY <br /> Owner: EVERETT COMMUNITY COLLEGE —' <br /> - - - Tenant GSF LEARNING RESOURCE CENTER <br /> All,Date: 1/13/2022 <br /> Proposed Use:COMMERCIAL <br /> Desaiption: EST4 PANELW/VOICE-ECCGSF LEARNING/COB KOUKEL.SET <br /> RESOURCECENTER " <br /> C <br /> ET <br /> FIRE ALARM SYSTEMS <br /> FIRE ALARMReviewed By: Date: XPELL 1/20 <br /> 22 77 <br /> EvCC fice set —Fre/Planning Set <br /> e <br /> LEARNING RESOURCE BUILD <br /> z <br /> 1001 N.BROADWAY AVE,EVERETT,WA 98201 ti <br /> APPLICABLE BUILDING CODES SCOPE OF WORK FIRE ALARM BILL OF MATERIALS <br /> 2018 INTERNATIONAL BUILDING CODE BUILDING DESCRIPTION:EDUCATIONAL BUILDING TOTAL NEW SYMBOL � MFG. MODEL# DESCRIPTION DETAIL REVI REV2 <br /> BUILDING OCCUPANCY:A-3,B,5 1 FACP EST 3-CAB14B _ EST4 BACK BOX F _, _ <br /> 2016 NFPA 72 n <br /> SPRINKLERED:FULLY rt � <br /> 2017 NFPA 70 PERFORMANCE CLASS:B <br /> A <br /> SCOPE: _ - <br /> 1 EST 4-CAB24DR EST4 INNER AND OUTER DOORS F I JAN 26 N22Q <br /> I <br /> ------- PERFORMANCE SYSTEMS INTEGRATION LLC IS PROVIDING A FIRE ALARM SYSTEM CONSISTING OF: 2 _ EST 3-CHAS7 EST4 CHASSIS ASSEMBLY C " `4 <br /> - <br /> CENTRAL STATION MONITORING NEW EST4 FIRE ALARM CONTROL PANEL WITH VOICE EVACUATION FOR NEW CONSTRUCTION. -_ --___ —__ A-I - r-__ __- ,TYDT V Permit e'a z <br /> 1 EST 4-BRKT-CB EST4 MOUNTING BRACKET w <br /> TRANSMISSION TYPE:RADIO • FULL NOTIFICATION APPLIANCE COVERAGE, - `I / Y <br /> PA -_- -- -- - <br /> COMMUNICATION <br /> .ATION TYPE: ID CONTACT • ELEVATOR CONTROL,FIRE SPRINKLER MONITORING,-AND OTHER REQUIRED DETECTION. 1 EST 3-PPS/M EST4 PRIMARY POWER SUPPLY <br /> PHONE NUMBER.(800)877-3624 <br /> MONITORING COMPANY:EMERGENCY 24 FA- 7 <br /> UN W <br /> ACC <br /> -- - 1 EST 3-BPS/M EST4 BACKUP POWER SUPPLY U <br /> FA-1_ <br /> SHEET INDEX 1 EST 4-CPU EST4 CENTRAL PROCESSOR FA-1 ---� <br /> -- --- ------- 1 EST 4-AUDTELS EST4 AUDIO INTERFACE <br /> FIRE ALARM SUBMITTAL REQUIREMENTS SHEET, DESCRIPTION REV 1 R��l. REV3 s _ O <br /> 1. the work site address and work activity location ' 2 EST 4-NET-TP EST4 NETWORK CONTROLLER _ s w <br /> 2. Work site owner or tenant contact name,address,and telephone number FA-01 BILL OF MATERIALS&GENERAL INFO X -- = � <br /> 3. Contractor or Installer information,including state electrical license number ------ --- -- -- - - 1 EST 3-SSDC2 EST4 SINGLE-LOOP SIGNATURE CONTROLLER FA-I - <br /> 4. Description of work FA-02 CALCULATIONS&MATRIX - W z <br /> 5. Three sets of scaled plans,not smaller thanIIx17inches.Yourplansmus}include: -- 1 EST 3-SDDC2 EST4 DUAL-LOOP SIGNATURE CONTROLLER - // ��� < <br /> 5.1. Floor plan indicating the use of all rooms FA-I V- <br /> 5.2. Riser Diagram FA-03 DEVICE LAYOUT-1ST FL WEST X �� � j Z ui <br /> 1 EST 3-MODCOM EST4 MODEM/COMMUNICATOR - z a > <br /> 5.3. Location of all alarm-initiating devices FA-1� Q <br /> 5.4. Location of all alarm notification devices,including candela ratings for visible devices FA-04 DEVICE LAYOUT-1ST FL EAST -- <br /> 5.5. Location of alarm control,transponders,and notification power supplies 4 EST 3-ZA40B EST440W AMPLIFIER Q� <br /> '? <br /> 5.6. Annunciation FA-05 DEVICE LAYOUT-2ND FL WEST - - -- FA-1 — "' O <br /> 5.7. Power connection ,.1 EST ____ 4-LCDLE EST4 USER INTERFACE ' 3 N <br /> S.B. Battery calcula}ions FA-06 DEVICE LAYOUT-2ND FL EAST -- - _ _ _ .._-. -_ _.__�._._-. _ EA.= -1 _ — z -( W <01 <br /> 7n CO <br /> 5.9. Voltage drop calculations — 0 EST 4 LCDAUDTELCAB-CB EST4 AUDIO CONTROL INTERFACE F -1 �, - o Q <br /> 5.10. Wiring types and sizes FA-07 DEVICE LAYOUT-3RD FL WEST - - --- - __ _ _ .__ __ _..__. _ _ _ _. _ _. _ ------ —__ __._.-- _- _- ---_- --- 3 <br /> 5.11. Manufacturer's data sheets with model numbers and informartion for equipment,devices,and 3 EST 4-MIC EST4 PAGING MICROPHONE - LL y °' <br /> materials FA- w U <br /> FA-08 DEVICE LAYOUT-3RD FL EAST - -- --- Z <br /> 5.12. Ceiling height and construction details 1 F- <br /> 5.13. Interface of fire safety control functions 3 EST 4-24L12S EST4 SWITCH BANK FA-.I:, _ _ ___ W N U <br /> FA-os RISER DIAGRAM(1 OF 3) x 19 EST 4-FIL EST4 BLANK FILLER PLATE 1 a LU w <br /> --- --- - - - - - FA-1' <br /> FA-10 RISER DIAGRAM(20F3) 1 EST 3-CAB5B EST4 SEMI-FLUSH ANNUNCIATOR WALL BOX <br /> WIRE SCHEDULE FA-11 RISER DIAGRAM(3 OF 3) -- - - <br /> --- - 1 EST 4-8ANNMT EST4 SURFACE ANNUNCIATOR WALL BOX JDK <br /> FA-12 CABINET DETAILS X IATOR 4 DRAWN BY <br /> 12 A_W_G PAIR - - -= FA-14. - DEVICE DETAILS(2 OF 3) ANKI EST 4 LCDANN EST4 ANNUNCEST 4-BANN EST4 OIATOR hJSERTE CINTERFACE 4— <br /> 14 AWG PAIR F A-I r -- CT <br /> 16AWGFAIa - -- FA-15 DEVICE DETAILS(30F3) X --- 2 _-- _ EST ____4-ANNAUDTEL ___ _ __EST4__ANNUNCIATOR AUDIO INTERFACE _ __ _ <br /> 18AWG PAIR _ _ CHECKED BY <br /> FPLR OR FPLP(AS REQUIRED) FA-1� <br /> _ _ <br /> SHIELDEDCABLE USE 1 SAE SS000689 DOCUMENT CABINET +1 <br /> t----- --_ - - :_.. ....._ REV. TITLE DATE <br /> SIGN ENTIONNE CIRCUITATIN - -__ FA-1s STANDARD DETAILS2 BPS EST BPS10A - - - - BOOSTER POWER SUPPLY <br /> CONVENTIONAL INITIATING DEVICE CIRCUIT(IDC) <br /> ZONE INPUT _ _.. - �i _ <br /> RELAY OUTPUT ' 11 EST SIGA-OSD OPTICAL SMOKE DETECTOR FA I; +1 <br /> NOTIF - - <br /> REMOTE ION NNUN IATOR 24VDC PO ER _-- • _ VICINITY MAP n .^• -�. ._EST _ _ SIGA-HRD _ RATE-OF-RISE HEAT DETECTOR <br /> AMOTEYRS232 ATORa5485oA POWER 12 EST SIGA-SB STANDARD DETECTOR BASE Faj - +1 1 <br /> DOOR HOLDER CIRCUIT Everett 2 �:� EST SIGA-SD DUCT SMOKE DETECTOR <br /> AUXILIARY RS232 DATA <br /> AUXILIARY 24VDC POWER Community -' <br /> College 2 FTRKI EST SD-TRK REMOTE TEST SWITCH FA-1-, <br /> ('NOTES:USE CABLE RATED FOR UNDERGROUND AND/OR WET CONDITIONS AS REQUIRED. 2 EST SD-T60 6011 SAMPLE TUBE _ <br /> FIRE ALARM CABLING CAN NEVER BE LARGER THAN 12AWG OR SMALLER THAN I8AWG. O REVISIONS <br /> [NON-POWER LIMITED CIRCUITS CAN NEVER SNARE PATHWAYS WITH POWER LIMITED CIRCUITS________ 9 2 © EST SIGA-278 MANUAL PULL STATION <br /> 1001 N Broadway Ave, FA- - PLOT DATE <br /> NORTHWEST <br /> NOTES TO — i <br /> - Everett,WA 98201 <br /> IN CONTRACTOR- - - -- EVERETT 2 STI STI-1130 MANUAL PULL STATION COVER 1/11/2022 <br /> -- I <br /> ----------.-- Delta Yard <br /> Q 2 Cc1s EST SIGA-CC1S SYNCHRONIZATION MODULE <br /> 1 ALL DEVICES PROVIDED AS PART OF THIS PROJECT SHALL BE INSTALLED PRIOR TO CONTACTING a _.. FA-1 <br /> ' <br /> PERFORMANCE SYSTEMS INTEGRATION,LLC(PSI)FOR SCHEDULING A PROGRAMMING TECHNICIAN. II >. DELTAS' 3 CTZ EST SIGA-CT2 DUAL-INPUT MONITOR MODULE FAc•14 PROJECT NUMBER j <br /> 2. WIRING MUST BE COMPLETE,DRY,AND FREE OF SHORTS AND GROUNDS WITH NO EXCEPTIONS PRIOR TO U — 1 OR EST SIGA-CR CONTROL RELAY FA-14 109993PW <br /> CONTACTING PSI FOR SCHEDULING A PROGRAMMING TECHNICIAN.. 3 - 2 CRH EST SIGA-CRH HIGH-POWER CONTROL RELAY <br /> FA-14 _ <br /> 3. WHEN CONDUIT IS REQUIRED,CONDUIT SIZE SHALL CONFORM TO CONDUIT FILL CAPACITIES AS PER THE 1 UIO EST SIGA-UI06 UNIVERSAL INPUT/OUTPUT MOTHERBOARD A = - PERMIT NUMBER <br /> REQUIREMENTS OF THE NATIONAL ELECTRICALCODE(NFPA70),THE LOCAL JURISDICTION,AND PROJECT N 1 EST MFC-A MULTIFUNCTION CABINET TBD <br /> SPECIFICAnoNs. m _ 4 MCR EST SIGA-MCR UIO-MOUNT CONTROL RELAY <br /> w - <br /> • B FA-I5 <br /> 4. UNDERGROUNDAND EXTERIOR CONDUITSSHALL HAVE WATER-TIGHT FITRNGSANDWIRESHALLBE S 1 MCT2 EST SIGA-MCT2 UIO-MOUNT DUAL-INPUT MONITOR MODULE Fn'15 <br /> APPROVED FOR WET LOCATIONS AS PER THE REQUIREMENTS OF NFPA 70 AND THE LOCAL JURISDICTION. > 31 � EST G4SVWF WALL-MOUNT SPEAKER STROBE _a FA-I J <br /> 5. ALL FIRE ALARM DEVICES AND JUNCTION BOXES EXPOSED TO THE WEATHER OR INSTALLED IN BELOW ------ --------------- - ------- 60 V"U' EST GCSVWF CEILING-MOUNT SPEAKER STROBE <br /> GRADE AREAS SHALL BE LISTED FOR USE IN A WET ENVIRONMENT.ALL DEVICES SHALL BE INSTALLED PER - FA-I c� <br /> THE MANUFACTURER'S RECOGNIZED WEATHER-/WATER-TIGHT INSTRUCTIONS.NO EXCEPTIONS. LABELING CONVENTION 10 EST GRSW-10 SPEAKER MOUNTING PLATE (1 0-PACK) FA- 5 <br /> S1-1 3 ® EST G4VWF WALL-MOUNT STROBE - SHEET TITLE <br /> 6. PROGRAMMING OF THE FIRE ALARM SYSTEM AND ASSOCIATED POINT DESCRIPTIONS WILL BE BASED ON EXAMPLE: p 1 1-1 EXAMPLE: d-A,2B 3•C 2,X ( � p IS <br /> S <br /> THESE DESIGN DRAWINGS.PSI MUST BE NOTIFIED OF ANY CHANGES TO ROOM USE OR DESIGNATIONS IN S 1-1 2 B 3 11 `� EST GCV W F C EI LING-MOUNT STROBE FA- S _ BILL OF MATERIALS <br /> WRITING.ANY CORRECTIONS RESULTING FROM CHANGES NOT SUBMITTED TO PSI MAY RESULT IN T L DEVICE NUMBER IN SEQUENCE _WIRE DESIGNATION WHEN>I OF SAME TYPE 2 EST GP10 STROBE MOUNTING PLATE (10-PACK) FA-1` &GENERAL INFO <br /> ADDITIONAL SYSTEM DEVICE COSTS AND/OR PROGRAMMING CHARGES. SPEAKER CIRCUIT# 1 I�,�I.CI EST WG4RF-HVMC WEATHERPROOF HORN STROBE 4 <br /> -CABLE TYPE(SEE WIRE SCHEDULE) FA-14 � _- <br /> 7. ALL DEVICES CONTAINING END-OF-LINE RESISTORS SHALL BE CLEARLY LABELED. 1 DEVICE NUMBER IN SEQUENCE NUMBER OF CABLES WHEN>1 1 EST BC-1 R EST4 BATTERY CABINET z <br /> � <br /> B. WHEN APPLICABLE,SERIAL NUMBERS(BARCODE LABELS)FROM INSTALLED DEVICES SHALL BE ATTACHED NAC CIRCUIT# 1 EST PT-IS SYSTEM EVENT PRINTER tET <br /> BOOSTER POWER SUPPLY# A,2B3,C2,X �n <br /> TO EITHER THE REDLINED DRAWING SET OR THE SUPPLIED BARCODE WORKSHEET. ONE CABLE,X-TYPE 1 TOM AES 7707-88-ULP-M MESH RADIO COMMUNICATOR FA-O l of 16 <br /> ONE CABLE,C-TYPE,DESIGNATION"2' _ N <br /> TWO CABLES,B-TYPE,DESIGNATION"3" 2 EST 12V65A 12V 65AH SEALED LEAD ACID BATTERY <br /> I 9. ANY DEVIATION FROM DESIGN MUST BE INDICATED ON PERFORMANCE SYSTEMS INTEGRATION,LLC(PSI) LONE CABLE,A-TYPE -_ S <br /> SHOP DRAWINGS AND RETURNED TO PSI UPONCOMPLETION OFTHEJOB. 4 DURACELL DURA12-8F 12V 8AH SEALED LEAD ACID BATTERY <br />