4027 4TH ST SE 2024 Plans 2025-09-30
>
Address Records
>
4TH ST SE
>
4027
>
Plans
>
4027 4TH ST SE 2024 Plans 2025-09-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/30/2025 4:07:47 PM
Creation date
9/30/2025 4:07:20 PM
Metadata
Fields
Template:
Address Document
Street Name
4TH ST SE
Street Number
4027
Permit
B2406-042
Year
2024
Notes
INSTALL TEMP JOB TRAILER
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STRUCTURAL NOTES: <br /> 1. DESIGN INFORMATION&LOADING: TV.) <br /> � <br /> 1.1. BUILDING CODE IBC,2015 EDITION ) <br /> LENGTH OF UNIT �T <br /> 1.2. ROOF LIVE LOAD 30 PSF(SNOW),Is=1.0,Cf=1.15 <br /> 1.3. FLOOR LIVE LOAD 50 PSF OR 2,0009 CONC.(OFFICE) <br /> 1.4. WIND CRITERION 120 MPH, EXP C,Kzt=1.0 <br /> 1.5. SEISMIC CRITERION SDS=1.00, le=1.0,SITE CLASS D,CATEGORY D <br /> 1.6. ASSUMED SOIL BEARING 1,500 PSF <br /> •7. WALL PLATE HEIGHT 9'-0" <br /> 1.8. ROOF SLOPE o <br /> 2:12 OR FLATTER o <br /> 2. CONCRETE: <br /> 2.1. DESIGN COMP.STRENGTH 2,500 PSI "o H <br /> 2.2• REINF.YIELD , c z <br /> 60 KSI ® v,; <br /> 3• MASONRY: am <br /> 3.1. 8x16x8 UNITS ASTM C-90,GRADE N <br /> 3.2• SET UNITS W/CORES VERTICAL&NO MORE THAN 3 HIGH,PER PLAN, Via` <br /> WITHOUT SOLID GROUTING CORES.SOLID GROUTED CORES OVER OVER S PADS & PIERS, NO. REQUIRED PER TABLE A O <br /> HIGH REQUIRES SPECIFIC ENGINEERING. - SEE DETAIL Al & A2/Dt SPACED EQUALLY V <br /> 4• WOOD: ANCHOR HOLD-DOWNS, SEE DETAIL B1 & B2/D1, <br /> 4.1. ALL WOOD TO BE HEM-FIR STUD GRADE OR BETTER. SPACED EQUALLY BETWEEN CORNERS <br /> 4.2• WOOD FRAMING AND SHEATHING WITHIN 6-INCHES OF GRADE TO BE <br /> PRETREATED FOR EXPOSURE TO MEET IBC 2015 2303.01.9. <br /> 4.3. CONNECTORS IN TREATED MATERIALS SHALL BE HOT-DIPPED GALVANIZED T <br /> OR STAINLESS STEEL PER IBC2015,2304.10.5. 12' WIDE MODULAR FOUNDATION PLAN SCALE: 14.4. SET MODULAR BUILDING SUCH THAT THE FLOOR JOISTS ARE A MINIMUM OF /8" = V-0" its <br /> 18-INCHES ABOVE FINISHED SUBGRADE BELOW BUILDING. `k3 <br /> 5. SPECIALTY ITEMS: ("MINUTE MAN PRODUCTS,Inc."(800)438-7277 TABLE A a o <br /> www.minutemanproducts.com,OR EQUIVALENT.) vi ! <br /> 5.1. METAL PIERS TO BE CAPABLE OF SUPPORTING 6,000# MODULE RAIL PIER/PAD SPACING 1r0 N z N grbIe <br /> INSTALL PIER/PADS UNDER CHASSIS, SPACED EQUALLY BETWEEN CORNER PIERS � Z <br /> 5•2• HOLD-DOWNS SET IN SOIL AND LOOSE GRAVEL SHALL BE SOIL ANCHOR m z a <br /> AUGAR-TYPE SET VERTICAL W/STABILIZER PLATE OR HEAD;OR DRIVEN INSTALL HOLD-DOWNS, SPACED EQUALLY BETWEEN CORNER HOLD-DOWNS <br /> ANCHOR W/STABILIZER PLATE OR HEAD,W/A MIN.DESIGN WORKING 3 w 3 0 LOAD OF 3,150#AND AN ULTIMATE LOAD OF 4,725#.NUMBER OF ANCHORS LENGTH OF UNIT # PADS & PIERS # HOLD-DOWN ANCHORS Q m jE 3 Its <br /> AS INDICATED ON TABLE A.CORNER TIE-DOWNS TO BE WITHIN 3'-0"OF THE EACH SUPPORT RAIL EA.SIDE EA.END o z ff <br /> BUILDING CORNER.TIE-DOWNS OTHER THAN AT THE CORNERS SHALL BE g <br /> SPACED EQUALLY.EACH INDIVIDUAL EQUALLY SPACED TIE DOWN SHALL BE 32'-0" 8 3 2 N $ <br /> WITHIN 4'-0"OF THE EQUAL SPACING. 40'-0" 10 4 2 0 <br /> 5.3. TIE-DOWNS TO STABLE CONCRETE SHALL BE EITHER A MMA-I8-THDLS FOR 42'-0" 10 4 2 <br /> PRE-POURED CONCRETE OR A MMA-42-210-PDH POUR INTO THE 44'-0" 11 <br /> CONCRETE.NUMBER OF ANCHORS PER 4 2 <br /> 5.4. TIE-DOWNS SET IN AN ASPHALT ROADWAY 48'-0" 11 <br /> „ OR PARKING ARE 4 z <br /> A SHALL BE 2 Z <br /> ROCK TYPE ANCHORS 56'-0" 13 5 2 < (D 0 o 5.5. INSTALL GROUND PORTION OF THE ANCHOR PRIOR TO SETTING THE 60'-0" 14 5 2 Z ¢ N BUILDING.CONNECT ANCHOR TIES TO BUILDING ONLY AFTER BUILDING IS Q Q a <br /> FULLY BLOCKED AND LEVELED. 0 <br /> 5.6. INSTALL ALL SPECIALTY ITEMS PER THE MANUFACTURER'S F- 0 J Z Q in <br /> RECOMMENDATIONS.SEE INSTALLATION INSTRUCTION MANUAL. <br /> 4. VENTING: z m O I j 2 <br /> > a 00 LU , <br /> 4.1. PROVIDE UNDER FLOOR VENTILATION PER IBC CODE AND LOCAL = U ui 0) 0 <br /> REQUIREMENTS AT 1 NET SF OF VENTILATION PER 150 SF OF FLOOR AREA. F.. o o 0 <br /> 4.2• IF A SUITABLE VAPOR RETARDER IS INSTALLED THE RATIO MAY BE LL z a, <br /> INCREASED TO Xsoo,IF ACCEPTABLE TO THE LOCAL BUILDING OFFICIAL. o Z g N <br /> 6. ACCESS: <br /> 6.1. PROVIDE ACCESS TO THE UNDER FLOOR AREA PER THE CODE. (� ¢ J LLJ z <br /> 6.2. PROVIDE 12"MIN.CLEARANCE FROM SOIL TO UNDERSIDE OF ALL BUILDING �S1pNAL �� ��Eo 'p�'� o LL o <br /> m <br /> SUPPORT MEMBERS. SIPO��V �G1ST /� �5� �N Qv �pW C� U Q 0 a <br /> 7. SITE CONDITIONS: i0 4 � � <br /> 7.1. FOUNDATION SUBGRADE TO BE UNDISTURBED NATIVE SOILS OR 23 ��� v < N Cl 'aa o <br /> STRUCTURAL FILL,COMPACTED TO 95%OF THE STANDARD PROCTOR <br /> DENSITY PER ASTM D-698. Na O o 0 <br /> 7.2. SLOPE FINISHED GRADE AWAY FROM THE BUILDING FOUNDATION AT A MIN. ,r+ �, OREGON REVISION DATE: <br /> GRADE OF 5%FOR THE FIRST 10-FEET AND 2%THEREAFTER TO A SUITABLE Lti l9Q` Gj O tnp q C.� G 19378 ��• 10/05/2019 <br /> DISCHARGE. 49 OF G F,4 T•23, \GG �� L <br /> N f9. BR1G N W. BR �ONA4� 1 of 2 <br /> Jt101S�5 e/30/z0 RENEWS: DECEWBER 31 20,9 �—, g, ,�21 SHEET: 12 <br /> -- - MDREW WEIDI <br />