|
a
<br /> °°"° moo, IRRIGATION NOTES M 'T H U N
<br /> \ Q/ j/
<br /> Q1 \ \ l �%L 1. ALL PLANTING AREAS SHOWN WITHIN LIMITS OF WORK SHALL BE IRRIGATED WITH AN SEATMEIPm56,12DIwashnWaY,CM
<br /> AUTOMATIC IRRIGATION SYSTEM. CONTRACTOR TO MAKE ANY AND ALL REQUIRED
<br /> S°aHIe,WA98107/206.623.3344
<br /> g / v °ss ADJUSTMENTS TO THE IRRIGATION PLAN TO ASSURE COMPLETE AND ADEQUATE SAN FRANCISCO/669 MA Sk e,#3oo
<br /> CV San RanCl.M CA 941G4/415.956.6688
<br /> coL COVERAGE WITH MINIMUM OVERSPRAY.
<br /> _S, V °V/ N � \ LOS ANGELES 15e3TAdamaR d
<br /> �� / FD�� 2. SEE DETAIL SHEET L2.02 FOR ADDITIONAL REQUIRED EQUIPMENT. Cul-CIIy,CA 902321323.93z215G
<br /> 111KERACK ml6,u...m
<br /> YD, u 3. IN NO CASE SHALL LATERAL PIPE SIZING RESULT IN FLOW VELOCITIES OVER 5 FPS
<br /> ` s 5 DROP�IRR °coL 4. MAINLINE PIPE SIZE SHALL BE 2" UNLESS NOTED OTHERWISE. MAINLINE PIPE NAKANO
<br /> ASSOCIATES
<br /> € \ LT ssc o rENTRANCE EXTENDING TO QUICK COUPLER VALVES SHALL BE 1-1/2". MINIMUM ALLOWABLE LANDSCAPE ARCHITECTS
<br /> \ �^ I PRLA,,_ti I 9 SIZE OF LATERAL PIPE IS 3/4". /
<br /> LANDSCAPED 853 Hiawatha Place S.
<br /> _ Seattle, WA 98144
<br /> OWN Tel:206.292.9392
<br /> 5 SCHEMATICALLY VALVES, MAIN LIFOR GRAPHIC PURPOSES.LINES, AND PIRRIGATOINT ION CONNECTIONIMENT SHALL HREMAIN www.nakanoassociates.com
<br /> 4_ CONc wry" i \ coNc CLEAR OF ALL PAVEMENT, WALLS, TREES, AND OTHER EXISTING AND PROPOSED SITE
<br /> P__ LP co c .A ELEMENTS UNLESS SPECIFICALLY NOTED ON THE PLANS OR DIRECTED BY THE
<br /> \z _ - BRICK
<br /> P LP \ LANDSCAPE ARCHITECT. PROJECT
<br /> 1 / i IN DOx BrAMT[ TION
<br /> c, \� \, so _ _� ®Ic R€FA s ALL PIPE SHOWN UNDER PAVING ADJACENT AND PARALLEL TO PI_ANTFD AREAS IS Learning Resource
<br /> {' 5„
<br /> L _ �� � SCHEMATIC AND INTENDED TO RF PLACED IN THAT PI ANTING BLD. Center
<br /> . SLE€VING IS REQUIRED FOR AL IRRIGA110N LINES AND CONTROL WIRES UNDER NEW
<br /> "U
<br /> S
<br /> -�- �� ;• - _ LOCATION
<br /> e ` + 14 C f f cross c' / j�-° \ AND EXISTING PAVEMENT, WALL}, CURBS, FTC. CONTRACTOR IS RESPONSIBLE FOR 2000 Tower Street
<br /> COORDINATION OF _LLLVING INSTALLATION AND ,SPECIFIC LOCATION FOR COMPLETE
<br /> / t INSTALLATION OF WORK. LXTLND SLEEVING 1`-0" BEYOND THE EDGE OF PAVING: Everett,WA 9 01
<br /> t 15 9 / WX YD `t �' cRAss
<br /> a„O \ - _ s , F AL WIRING TO BE IN .SEPARATE III_FFV€ INSERTED IN PIPING SLLEVE.
<br /> fA, AL SL€FVING SHALL BE SCHEDULE 80 PVC, SIZED TWICE THE DIAMETER OF
<br /> 3/4' #/y INSERTED PIPE, AND MIN, 3" UNLESS OTHERWISE NOTED. PREPARED FOR
<br /> GRASS �. V \ .�/' �,/
<br /> Everett Community
<br /> --�- \ A 7. MAIN LINE PIPING LAYOUT, SLEEVES, AND VAI-VF LOCATIONS SHALL. BE `STAKED IN
<br /> ! \ - I - ! f `\ `, FIELD BY CONTRACTOR. STAKING SHIN I BE APPROVED BY THE LANDSCAPE Col
<br /> Ili,/ <
<br /> / 16 3/a P\,\ !' \\ -3/a' 1t e4 /! / f J \ � ARCHITECT PRIOR TO INSTAITION.
<br /> e % 17 1„ a„/ - 1' / .,. 4 Ivy'
<br /> _ 1Yz h n., h\ i f , 8. VERIFY STATIC WATER PRFSSURL AT POINT OF CONNECTION PRIOR TO RFGINNING
<br /> 13 1 \ ' ! / - / <' WORK. STATIC PRF �SURL IN CITY WATER MAIN I ESTIMATED TO RF 69P_L SUBMIT
<br /> O RESULTS TO OWNER'S REPRESENTATIVE IN WRITING PRIOR TO INSTALLATION OF
<br /> \ p• T/3/a" �\• �C�Y\ * / /\ � WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING AVAILABLE WATER
<br /> 5 1 0 PRESSURE AND FLOW IS SUFFICIENT TO OPERATE IRRIGATION SYSTEM.
<br /> o + i 3/a /n \ y/
<br /> 9. SET VALVE BOXES SQUARE TO ADJACENT BUILDING OR PAVING.
<br /> 41' P� 0. PLACE ALL HEADS MIN 4 FROM CURB WALK PAVED AR AND STRUCTURES.
<br /> a � Q-1 1 S S TEAS 11. APPROXIMATE LOCATION FOR CONTROLLER IS SHOWN ON PLAN. APPROVAL OF
<br /> / FINAL LOCATION IN THE FIELD BY OWNER'S REPRESENTATIVE IS REQUIRED PRIOR TO
<br /> 4.5`' INSTALLATION.
<br /> 3/a" 1. �' I°° ti.:5 .6A
<br /> 12. ALL ELECTRICAL WIRES, VALVE WIRES, COMMUNICATION CABLES, AND CONDUIT
<br /> w c ° / ✓ NECESSARY TO INSTALL CONNECTIONS BETWEEN AUTOMATIC CONTROL VALVES AND
<br /> ga 7 � 85.05 / CONTROLLER ARE THE RESPONSIBILITY OF THE CONTRACTOR.
<br /> BUILDING OVERHANG
<br /> 13. ELECTRICAL POWER IS REQUIRED FOR THE CONTROLLER AND CONTROL
<br /> All"
<br /> COMPONENTS.co c 8 / 1YdOi . 4'� ,^/' 14. MAINLINE SHALL BE 24" MIN BURIAL AND ALL LATERAL LINES SHALL BE MIN. 18" �P�GOP,O.OTTFS�iCO
<br /> LEARNING RESOURCE CENTER / \
<br /> g a sus\ /Y2 /"% BURIAL. PLACE NO ELLS OR TEES BENEATH PAVING.
<br /> ^STOPp• as. oy� ,So
<br /> 15. ALL WORK WITHIN THE CRITICAL ROOT ZONES OF EXISTING TREES SHALL BE IN ry
<br /> ACCORDANCE WITH TREE PROTECTION SPECIFICATIONS AND DETAIL. TRENCHING BY
<br /> CONTROLLER SYSTEM CABINET / o 03'/ '/ �' /'\ A HAND IS REQUIRED WITHIN DRIPLINE OF EXISTING TREES. TRENCHES HAVING sso°gs EXp,O°t�G�
<br /> 03 10 e� / y \ EXPOSED TREE ROOTS SHALL BE BACKFILLED WITHIN 24 HOURS UNLESS �AN0.5cgPEP
<br /> ADEQUATELY PROTECTED BY MOIST SOIL OR MULCH AS APPROVED.
<br /> E s / CONIC
<br /> (�9\) / \- 16. NO IRRIGATION WATER SHALL HIT THE TRUNK OF EXISTING TREES TO BE SAVED.
<br /> a / " • x o - -- %/i !// '%3/"' j /" i / / 17. LOCATE RAIN SENSOR PER PLAN. FINAL INSTALLATION DIRECTED BY LANDSCAPE
<br /> ARCHITECT IN THE FIELD.
<br /> 85.1
<br /> lee 18. MORE THAN ONE AUTOMATIC CONTROL VALVE CAN BE LOCATED IN A SINGLE VALVE
<br /> 852 -r- 4.8 \¢ / 1 /' / BOX IS BOX IS SIZED TO PROVIDE EASY ACCESS FOR MAINTENANCE OF EACH
<br /> s \ 5 . 1 1„! 4 VALVE.
<br /> T i \S ♦ \\ \ �/ ' 11 Y `�$ • 4 // ` / 19. RUN TWO SPARE WIRES TO THE FARTHEST TWO VALVE CLUSTERS. PASS THROUGH
<br /> WATER CONN ION 3/a" / / EACH VALVE CLUSTER ON THE SITE AND PROVIDE ONE LOOP (24") IN EACH/ALL
<br /> TO CAMPUS MAINLINE I I tea" / \ /
<br /> - - _ - _ _ - _ �_l� / �\ CLUSTER MANIFOLDS.
<br /> - - \ - \ tATCHLINE�-F-BEE t2:0'7 W lYd'�
<br /> ?, O 20. USE TEFLON TAPE ON ALL THREADED PVC FITTINGS.
<br /> 21. NEITHER BENDS NOR JOINTS SHALL BE PERMITTED IN SLEEVES AND PIPES UNDER
<br /> m IRRIGATION SCHEDULE PAVEMENT. �I.OTiESEN
<br /> E SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI DETAIL SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI DETAIL SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI DETAIL SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI DETAIL
<br /> a P.GILMOUR,R.GUCK
<br /> Q HUNTER MP CORNER W/ RAINBIRD 1806-SAM-PRS30 30 9/L2.02 v c e ® RAIN BIRD 1804-SAM-PRS-5 SERIES STREAM 30 1O/L2.02 IRRIGATION LATERAL LINE: PVC SCHEDULE 40 6/L2.02 g (HUNTER MP CORNER ROTATOR NOZZLE ON RAINBIRD ZISS HUNTER MP2000 W/ RAINBIRD 1806-SAM-PRS30 30 9/L2.02 CST o H F
<br /> Y HUNTER MP2000 ROTATOR NOZZLE ON RAINBIRD STREAM BUBBLER 4.0" POPUP WITH CHECK VALVE SIZE PER PLAN NO SMALLER THAN 3/4"
<br /> b 1806-SAM-PRS30 SPRAY HEAD, 6"POP-UP W/ 1806-SAM-PRS30 SPRAY HEAD, 6"POP-UP W AND PRESSURE REGULATOR. __ _ J.YAMAGUCHI
<br /> FACTORY INSTALLED CHECK VALVE, PRESSURE / _ IRRIGATION MAINLINE: 2" PVC SCHEDULE 40 6 L2.02
<br /> REGULATED TO 30 PSI. T=TURQUOISE ADJ ARC FACTORY INSTALLED CHECK VALVE, PRESSURE UNLESS NOTED OTHERWISE /
<br /> 45-105 . REGULATED TO 30 PSI. K=BLACK ADJ ARC 90-210,
<br /> s ) SYMBOL MANUFACTURER MODEL/DESCRIPTION DETAIL
<br /> G=GREEN ADJ ARC 210-270, R=RED 360 ARC). -__--_--_-_-_ PIPE SLEEVE: PVC SCHEDULE 80 8/L2.02
<br /> ® HUNTER MP CORNER W/ RAINBIRD 1812-SAM-PRS30 30 9/L2.02 RAIN BIRD PEB-PRS-D 7/L2.02
<br /> (HUNTER MP CORNER ROTATOR NOZZLE ON RAINBIRD LE7�m HUNTER MP2000 W/ RAINBIRD 1812-SAM-PRS30 30 9/L2.02 VALVE CALLOUT
<br /> (HUNTER MP2000 ROTATOR NOZZLE ON RAINBIRD 1", 1-1/2", 2" PLASTIC INDUSTRIAL VALVES. LOW
<br /> a 1812-SAM-PRS30 SPRAY HEAD, 12"POP-UP W/ FLOW OPERATING CAPABILITY, GLOBE CONFIGURATION. # VALVE NUMBER
<br /> 1812-SAM-PRS30 SPRAY HEAD, 12"POP-UP W WITH PRESSURE REGULATOR MODULE.
<br /> a FACTORY INSTALLED CHECK VALVE, PRESSURE /
<br /> REGULATED TO 30 PSI. T=TURQUOISE ADJ ARC FACTORY INSTALLED CHECK VALVE, PRESSURE
<br /> 6 REGULATED TO 30 PSI. K=BLACK ADJ ARC 90-210,
<br /> 0 RAIN BIRD 44-LRC 4/L2.02
<br /> e Q 45-105).
<br /> G=GREEN ADJ ARC 210-270, R=RED 360 ARC). _
<br /> ® ®® TH
<br /> HUNTER MP STRIP W/ RAINBIRD 1806-SAM-PRS30 30 9/L2.02 CORROSION-R BRASS QUICK-COUPLING
<br /> ESISTA TPSTAINLE STAINLESS STEEL SPRING,
<br /> 1 Lsr m ssT (HUNTER MP STRIP ROTATOR NOZZLE ON RAINBIRD (}e�}r,5 HUNTER MP3000 W/ RAINBIRD 1806-SAM-PRS30 30 9/L2.02 LOCKING THERMOPLASTIC RUBBER COVER, AND VALVE SCHEDULE
<br /> a 1806-SAM-PRS30 SPRAY HEAD, 6"POP-UP W/ (HUNTER MP3000 ROTATOR NOZZLE ON RAINBIRD 2-PIECE BODY.
<br /> 1B06-SAM-PRS3O SPRAY HEAD, 6-POP-UP W/
<br /> NUMBER MODEL SIZE TYPE GPM DESIGN P51
<br /> m � FACTORY INSTALLED CHECK VALVE, PRESSURE
<br /> E REGULATED TO 30 PSI. LST=IVORY LEFT STRIP, FACTORY INSTALLED CHECK VALVE, PRESSURE Z KBI BTU-E 1 RAIN BIRD PEB-PRS-D SIZE
<br /> BUBBLER GPM 30
<br /> a SST=BROWN SIDE STRIP, RST=COPPER RIGHT STRIP). REGULATED TO 30 PSI. B=BLUE ADJ ARC 90-210, PVC BLOCKED TRUE UNION BALL VALVE S.O.V., SAME 3/L2.03 2 RAIN BIRD PEB-PRS-D 1" BUBBLER 23.00 30
<br /> Y=YELLOW ADJ ARC 210-270, A=GRAY 360 ARC). SIZE AS PIPE 3 RAIN BIRD PEB-PRS-D 1" SHRUB ROTARY 27.06 30
<br /> Q a® HUNTER MP STRIP W/ RAINBIRD 1812-SAM-PRS30 30 9/L2.02
<br /> t n LsT RSTSS 4 RAIN BIRD PEB-PRS-D 1" SHRUB ROTARY 28.53 30
<br /> � (HUNTER MP STRIP ROTATOR NOZZLE ON RAINBIRD AQUA HUNTER MP3000 W/ RAINBIRD 1812-SAM-PRS30 30 9/L2.02 © HUNTER IC-2400-M 1/L2.03
<br /> (HUNTER MP3000 ROTATOR NOZZLE ON RAINBIRD MODULAR CONTROLLER, 24 STATIONS, OUTDOOR 5 RAIN BIRD PEB-PRS-D 1-1/2" SHRUB ROTARY 29.56 30
<br /> 1ACTORYM INSTALLED
<br /> SPRAY HEAD, 12"POP-UP W/ MODEL, METAL CABINET. COMMERCIAL USE. WITH 6 RAIN BIRD PEB-PRS-D 1" SHRUB ROTARY 18.95 30
<br /> s FACTORY INSTALLED CHECK VALVE, PRESSURE FACTO SAM INSTALLED
<br /> SPRAY HEAD, , POP-UP W/ THREE ICM-600 MODULES INCLUDED. 7 RAIN BIRD PEB-PRS-D 1" SHRUB ROTARY 11.59 30 CITY OF EVERETT
<br /> s REGULATED TO 30 PSI. LST=IVORY LEFT STRIP, FACTORY INSTALLED CHECK VALVE, PRESSURE 8 RAIN BIRD PEB-PRS-D 1" SHRUB ROTARY 9.70 30 REVIEWED FOR PERMIT
<br /> s € REGULATED TO 30 PSI. B=BLUE ADJ ARC 90-210,
<br /> e SST=BROWN SIDE STRIP, RST=COPPER RIGHT STRIP). Y=YELLOW ADJ ARC 210-270, A=GRAY 360 ARC). HUNTER WRF-CLIK 9 RAIN BIRD PEB-PRS-D 1" SHRUB ROTARY 13.26 30
<br /> bt}o HUNTER MP1000 W/ RAINBIRD 1806-SAM-PRS30 30 9/L2.02 RAIN/FREEZE SENSOR, INSTALL WITHIN 1000 FT OF 10 RAIN BIRD PEB-PRS-D 1" SHRUB ROTARY 18.84 30
<br /> = ITII
<br /> (HUNTER MP1000 ROTATOR NOZZLE ON RAINBIRD 8 8 HUNTER MP800SR W/RAINBIRD 1812-SAM-PRS30 30 9/L2.02 CONTROLLER, IN LINE OF SIGHT. 22-28 VAC/VDC 11 RAIN BIRD PEB-PRS-D 1" SHRUB ROTARY 2.54 30 IRRIGATION PLAN-
<br /> AOJ. 360 100 MA POWER FROM TIMER TRANSFORMER. MOUNT 12 RAIN BIRD PEB-PRS-D 1" SHRUB ROTARY 9.70 30
<br /> s = 1806-SAM-PRS30 SPRAY HEAD, 5-POP-UP W/ (HUNTER MP800SR ROTATOR NOZZLE ON RAINBIRD
<br /> a ; FACTORY INSTALLED CHECK VALVE, PRESSURE 1812-SAM-PRS30 SPRAY HEAD, 12"POP-UP W/ AS NOTED. INCLUDES GUTTER MOUNT. 13 RAIN BIRD PEB-PRS-D 1-1/2" SHRUB ROTARY 31.51 30 NORTH
<br /> REGULATED TO 30 PSI. M=MAROON ADJ ARC 90 TO FACTORY INSTALLED CHECK VALVE, PRESSURE 14 RAIN BIRD PEB-PRS-D 1" SHRUB ROTARY 24.72 30
<br /> REGULATED TO 30 PSI. OR = ORANGE ADJ ARC 90 � HUNTER HFS-200 3/L2.02 210, L=LIGHT BLUE 210 TO 270, O=OLIVE 360 15 RAIN BIRD PEB-PRS-D 1" SHRUB ROTARY 7.49 30
<br /> s ARC). TO 210, LIME TO 360 ARC). FLOW SENSOR FOR USE WITH ACC CONTROLLER, 2°
<br /> z ) ) SCHEDULE 40 SENSOR BODY, 24 VAC, 2 AMP. 16 RAIN BIRD PEB-PRS-D 1" SHRUB ROTARY 27.88 30 1904.00
<br /> NOT SHOWN ON PLAN. SEE POC DETAIL 17 RAIN BIRD PEB-PRS-D 1" SHRUB ROTARY 22.11 30
<br /> f Q QQo HUNTER MP1000 W/ RAINBIRD 1812-SAM-PRS30 30 9/L2.02 Goo HUNTER MP815 W/RAINBIRD 1812-SAM-PRS30 30 9/L2.02 18 RAIN BIRD PEB-PRS-D 1" SHRUB ROTARY 14.45 30 07/24/2020
<br /> s (HUNTER MP1000 ROTATOR NOZZLE ON RAINBIRD HUNTER MP815SR ROTATOR NOZZLE ON RAINBIRD
<br /> 19 RAIN BIRD PEB-PRS-D i" SHRUB ROTARY 21.69 30
<br /> 1812-SAM-PRS30 SPRAY HEAD, 12"POP-UP W ®o POINT OF CONNECTION 1/L2.02
<br /> ' r € 1812-SAM-PRS30 SPRAY HEAD, 12"POP-UP W/ /
<br /> c FACTORY INSTALLED CHECK VALVE, PRESSURE FACTORY INSTALLED CHECK VALVE, PRESSURE M WATER METER 2"
<br /> g � REGULATED TO 30 PSI. M=MAROON ADJ ARC 90 TO REGULATED TO 30 PSI. M=MAROON AND GRAY ADJ SEE CIVIL
<br /> ` 210, L=LIGHT BLUE 210 TO 270, O=OLIVE 360 ARC 90 TO 210, L=LIGHT BLUE AND GRAY 210 TO 20 10 0 20 40D
<br /> moo
<br /> o
<br /> ARC). 270 ARC, O=OLIVE AND GRAY 360 ARC).
<br /> ffi ON
<br /> 5 SCALE IN FEET
<br /> PERMIT
<br /> \\NASERVER1\the server\Pro^ects\E=vCC Learnin Resource Center\CAD�LRC- L2.00 IRRIGATION PLAN.dwg, 7/17/2020 5:42:05 PM, AutoCAD-PDF (General ©2016MITHUN,INC.
<br /> � g PDF (General Documentation).pc3 NnT FnR CnNSTRI If'.TI(1N
<br />
|