ScheduleFire Sprinkler Pipe <br /> • Schedule <br /> Submittal <br /> s <br /> FM Approved and Fully Listed Sprinkler Pipe SCHEDULE 10 SPECIFICATIONS <br /> Wheatland's Schedule 10 and Schedule 40 <br /> steel fire sprinkler pipe is FM Approved and UL, NOMINAL NOMINAL <br /> C-UL and FM Listed. N NOM OD NOM ID WALL WEIGHT UL CES <br /> mm In. mm In. mm Ibs./ft. kg/m Lift <br /> Approvals and Specifications <br /> Both products meet or exceed 11/4 1.660 1.442 36.6 .109 2.77 1.81 7.3 61 <br /> the following standards: <br /> 1�/z 1.900 48.3 42.7 .109 2.77 2. 3.11 5.8 61 <br /> 2 2.375 60.3 2.157 .109 2.77 2.64 3.93 4.7 37 <br /> • ASTM A795,Type E, Grade A(Schedule 40) <br /> 2'/z 2.875 73.0 2.635 66.9 0 3.05 3.53 5.26 3.5 30 <br /> • NFPA 13 <br /> 3 3.500 88.9 3.260 82.8 .20 05 4.34 6.46 2.6 19 <br /> Manufacturing Protocols <br /> Schedule 10 and Schedule 40 are subjected 4 4.500 114.3 4.260 .2 .120 3.05 .62 8.37 1.6 19 <br /> to the toughest possible testing protocols to 5 5.563 141.3 134.5 .134 3.40 7.78 1.58 1.5 13 <br /> ensure the highest quality and long-lasting <br /> performance. 6 6.625 1 6.357 161.5 .134 3.40 9.30 13.85 1.0 10 <br /> 8 8.6 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 <br /> Finishes and Coatings <br /> All Wheatland black steel fire sprinkler pipe calc d using Standard UL CRR formula,UL Fire Protection Directory,Category WZY. <br /> RR is a ratio value used to measure the ability of a pipe to withstand corrosion. <br /> up to 6" receives a proprietary mill coating to hreaded Schedule 40 steel pipe is used as the benchmark(value of 1.0). <br /> ensure a clean,corrosion-resistant surface that <br /> outperforms and outlasts standard lacquer <br /> coatings.This coating allows the pipe to be SCHEDULE 40 SPECIFICATIONS <br /> easily painted,without special preparation. <br /> Schedule 10 and Schedule 40 can be ordered in NOMINAL NOMINAL <br /> black,or with hot-dip galvanizing,to meet NPS NOM OD NOM ID WALL WEIGHT UL PIECES <br /> FM/UL requirements for dry systems that meet in. mm in. mm in. mm Ibs./ft. kg/m CRR Lift <br /> the zinc coating specifications of ASTM A795 <br /> or A53.All Wheatland galvanized material is 1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 <br /> also UL Listed. 1va 1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 <br /> Product Marking 1Yz 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 <br /> Each length of Wheatland fire sprinkler <br /> 2 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30 <br /> pipe is continuously stenciled to show <br /> the manufacturer,type of pipe,grade,size Calculated using Standard UL CRR formula,UL Fire Protection Directory,Category WZY. <br /> and length.Barcoding is acceptable as a The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. <br /> supplementary identification method. Threaded Schedule 40 steel pipe is used as the benchmark(value of 1.0). <br /> UL C UL F M <br /> APPROVED <br /> SUBMITTAL <br /> • - <br /> PROJECT: CONTRACTOR: DATE: <br /> ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: <br /> LOCATIONS: COMMENTS: <br /> ❑ BLACK ❑ HOT-DIP GALVANIZED <br /> Wheatland Tube <br /> :•• .- <br /> •• •• - twheatiandTube <br /> JMC STEEL GROUP <br />