Application Operation <br /> The i064 life safety system is a powerful intelligent solution for small The front panel provides an easy-to-use operator's interface,as <br /> to mid-sized buildings.Advanced analog technology delivers the ben- well as all the necessary controls for front panel programming. <br /> efits of flexible system installation,while a clean and easy-to-opera- A large back-lit 80-character LCD displays system status,event <br /> tote user interface makes panel operation and system maintenance details,and programming prompts.Large tactile control buttons are <br /> quick and intuitive. easy to see in low light conditions,and bright multi-color LEDs offer <br /> at-a-glance status indication. <br /> The smart choice <br /> Signature Series electronic addressing eliminates the tedium of <br /> setting dipswitches,and automatic device mapping ensures that <br /> each device resides on the system at its correct location.Mean- <br /> while,innovative programming features allow the system designer <br /> flRFMMM R@T <br /> to customize powerful built-in features to precisely suit the needs of 0 o [� <br /> the building owner. 0( <br /> ® «u o I o <br /> Flexibility built right in ® ® <br /> Two fully-programmable front panel switch/LED combinations <br /> provide an added measure of flexibility.Their slide-in labels take the � � o <br /> mystery out of custom applications,and present a clean finished <br /> appearance. ® ®®® O <br /> ® ®ED aOO� <br /> Perfect for retrofits ®� 0 <br /> The i064 is particularly well-suited to retrofit applications.All ® 0O® <br /> connections are made over standard wiring-no shielded cable <br /> required.This means that in most situations existing wiring can be <br /> used to upgrade a legacy control panel to iO-Series technology <br /> without the expense or disruption of rewiring the entire building. <br /> Control buttons <br /> Signals with a difference Button Description <br /> i064 NACs are configurable to fully support the advanced signal- System Reset Initiates a system reset. <br /> ing technology of GE Genesis and Enhanced Integrity notification ACK/Ponel Silences the panel and remote annunciators during <br /> appliances.These devices offer precision synchronization of strobes Silence an active trouble,supervisory,or alarm event and <br /> to UL 1971 standards.For Genesis devices,enabling this feature acknowledges new event activations. <br /> allows connected horns to be silenced while strobes on the same Signal Silence Alarm mode:Silences active notification appliances. <br /> two-wire circuit continue to flash until the panel is reset. Pressing Signal Silence a second time turns NACs back on. <br /> Drill Initiates a drill confirmation.Pressing drill a second time <br /> Clear-cut remote annunciation turns off the drill function. <br /> Remote annunciation is a strong suit of the i064.Up to eight an- Remote Dialer:Disables or enables dialer. <br /> nunciators can be installed on a single system.Compatible annun- Disconnect Dialer set to modem only:Disables or enables the <br /> ciators include a range of LED and LCD models that provide zone or common alarm relay. <br /> point annunciation,as well as common control capabilities. Left arrow Display mode:Moves the cursor to the left. <br /> Menu mode:Toggles between programming selections. <br /> The i064 also supports graphic annunciation with optional graphic Right arrow Display mode:Moves the cursor to the right. <br /> annunicator interface modules.Each interface provides common Menu mode:Retrieves a programming option's sub menu <br /> control,indicators,and LED drivers.Consult the Ordering Informa- and toggles between a programming option's selections. <br /> tion section for details. Up arrow Display mode:Advances to the previous event. <br /> Menu mode:Moves the cursor up. <br /> A complete line of accessories Down arrow Display mode:Advances to the next event. <br /> The i064 life safety system is supported by a complete line of Menu mode:Moves the cursor down. <br /> intelligent detectors,modules and related equipment.Consult the Enter Display mode:Displays selected event details. <br /> Ordering Information section for details. Menu mode:Retrieves a programming option's sub <br /> menu orjumps to the Save function in the menu. <br /> Entry mode:Enters the selected data into the system. <br /> Cancel Display mode:Exits the detailed information display. <br /> Menu mode:Exits the current menu level. <br /> Entry mode:Clears the current entry. <br /> Menu Display mode:Enters the menu mode <br /> Menu mode:Exits menu mode <br /> Space Enters a space,such as a space between words. <br /> Alphanumeric Entry mode:Pressing a button once enters the number <br /> keypad on the button.Pressing the button twice enters the <br /> secondary value. <br /> Programmable These buttons can be programmed to control or enable/ <br /> buttons disable a device,zone,or Panel NAC.The buttons can be <br /> labeled with a slip-in insert. <br /> Data Sheet 85005-0131 Issue 3 <br /> Not to be used for installation purposes.Page 2 of 8 <br />