SA-DACT Dialer <br /> The SA-DACT provides communications between the control panel The SA-DACT queues messages and transmits them based on <br /> and the central station over a telephone line system.It transmits priority(alarm,supervisory,trouble,and monitor).Activations are <br /> system status changes(events)to a compatible digital alarm com- transmitted before restorations. <br /> municator receiver over the public switched telephone network. The SA-DACT is installed on the plastic assembly and connects to <br /> The dialer is capable of single,dual,or split reporting of events to the main circuit board via a ribbon cable. <br /> two different account and telephone numbers.The modem feature <br /> of the SA-DACT can also be used for uploading and downloading <br /> panel configuration,history,and current status to a PC running the <br /> SA-DACT specifications <br /> i0-CU. <br /> Phone line type One or two loop-start lines on a public, <br /> SA-DACT Phone line 1 switched network <br /> wiring To wall <br /> Phone line 2 phonejack Phone line connector RJ-31/38X(C31/38X) <br /> Communication formats Contact ID(SIA DC-05) <br /> Phone cables Operating environment <br /> (supplied) RJ31 jacks p g <br /> Temperature 32 to 120°F 10 to 49°CI <br /> Humidity 0 to 93%RH,noncondensing at 90°F(32°C) <br /> ® The dialer phone lines connect to _Compatible DACRs <br /> °g = connectors on the dialer's main Receiver Models Formats <br /> �"pOU` circuit board.Phone line 1 <br /> 00 ^°4 ° Ademco 685 Contact ID <br /> connects to connector J4 and <br /> a7 FBII CP220 Contact ID <br /> g phone line 2 connects to <br /> ° <br /> connector Jl. Osborne-Hoffman OH 2O00 Contact ID <br /> ❑❑e=a e° � <br /> Radionics D6600 Contact ID <br /> D <br /> � ❑ <br /> Silent Knight 9800 Contact ID <br /> oo o �° Sur-Gard SG-MLRI,MLR2 Contact ID <br /> Specifications <br /> Device loops 1 loop Class B,Class A optional,supporting up Batteries Batteries must be sealed lead acid type only. <br /> to 64 device addresses Maximum charging capacity=26 An. <br /> Notification appliance 2 Class 6,Class A optional,2.5 amps each Loop circuit Maximum loop resistance:66 Q.Maximum <br /> circuits loop capacitance:0.7 NF.Style 4,6,and 7 <br /> Power supply 3.75 A FWR total at 120/230 VAC 60 Hz wiring.64 isolators maximum <br /> 3.0 A FWR total at 230 VAC 50 Hz Loop circuit max detector 1.5 mA(see the UL and ULC compatibility list <br /> 0.5 amps aux power standby current for your panel for the maximum quantity of <br /> NAC Operating voltage 24 VDC.NAC minimum voltage:19.5 VDC @ detectors per circuit) <br /> 20.4 V battery voltage Compatibility ID 100 <br /> SLC Loop operating 20 V peak-to-peak Alarm contact Form C 24 VDC @ 1 A(resistive load) <br /> voltage Trouble contact Form C 24 VDC @ 1 A(resistive load) <br /> Primary power 120 VAC,60 Hz,230 VAC 50-60 Hz Supervisory contact Form A 24 VDC @ 1 A(resistive load) <br /> Aux Power 1 24 VDC nominal at 500 mA.A SMK module is Environmental Temperature:0 to 49°C(32 to 120°F). <br /> (Continuous circuit) required when using the SIGA-UM module to Humidity:0 to 93%RH,noncondensing <br /> support two-wire smoke detectors. Terminal rating All terminals rated for 12 to 18 AWG(0.75 to <br /> Aux Power 2 24 VDC nominal at 500 mA. 2.5 sq mm) <br /> (Resettable circuit) Serial communications Voltage:2.55 V.Current:30 mA max <br /> Auxiliary output 19 to 25.7 VDC Remote annunciator 8 drops max,RS-485 Class B,Class A <br /> Base panel current draw Standby:155 mA Alarm:204 mA Input zones 16 max. <br /> Battery placement i064 cabinets accommodate up to 10 A/H Agency Listing UL,CSFM and ULC <br /> batteries.Use an external cabinet for larger <br /> battery sizes. <br /> Data Sheet 85005-0131 Issue 3 <br /> Not to be used for installation purposes.Page 6 of 8 <br />