Laserfiche WebLink
D/F ILLUMINATED PYLON Scale:3/8"=1'-0" CONSTRUCTION DRAWINGS TO BE PROVIDED FOR PRODUCTION <br /> CUSTOM A2-HWng 16'-0" OAH 29.7 square feet MAIN S T RUC I URC: <br /> BACKERS: 3"x 3"x.125 alum. tube frame all exposed surfaces painted Garbo Silver <br /> s Engineering request#29781 Gloss finish; 2 two required <br /> Strati� 9� 9 q ( ) q <br /> �1���iv has been submitted Face skinned with .125 alum. paint Garbo Silver Gloss-Chem weld to frame <br /> Back of Frame skinned w/.125 alum. paint Red semi gloss finish <br /> �* 8'-6-5/8" <br /> 211 <br /> CLADDING: .125 alum. -paint Red Semi-gloss finish; Lower section is removeable <br /> F-7 1 -1 =_ 3-1/4" BANK OF <br /> CLADDING 4mm Natural Brushed 50ACM Alucabond;V-groove back&fold returns at <br /> 21-1/2" V-8-1/211 �_OPEIu--,� ' �OPEN—,,� 1'-2" DETAIL: sides&ends secure to columns cladding w/3M dual lock fastener system <br /> 3-1/4" CLADDING .125 break formed alum. end caps mechanically fastened to main cladding <br /> 211 TOP VIEW External Cutoff Switch NIGHTTIME VIEW END CAPS: Paint Red semi gloss finish <br /> INSTALL: Cabinet to have internal steel as req'd. and is mounted with match plates to <br /> 8'-6-518" 3-1/4" sq. steel support and existing concrete foundation; all installation details to be provided <br /> 7'-411 �(� 2111211�-3-1/4" <br /> 211 to match engineering and city requirements. <br /> TOLERANCE 1116"ON ALL DIMENSIONS 3'-1/1611 LOWER PORTION OF <br /> CLADDING IS REMOVABLE <br /> TO ACCESS MATCH PLATE. <br /> II n [CHANNEL <br /> w A1A1r rTTrllf� TnT a__ 1 <br /> 5F UPPER PORTION IS FIXED CHANNEL LETTERS:I ERR: L two sets required <br /> TO HOUSE U.L.CUTOFF SWITCH. <br /> FACES: 1/2"thick Plaskolite 2406 LD acrylic w/routed back 5/16"from back <br /> 1'-7-1/2" leaving a 3/16"thick x 5/32"flange for drop in faces secured thru returns(see detail) <br /> 3'-5-518" 2'-7-1/2" Surface applied vinyl overlays to match colors shown w/3M overlaminate <br /> 6" 2'-6-1/811 <br /> 6" BANK O F A M E R I C A RETURNS: 2"deep .040 alum returns -aluminum Coil <br /> Bright Brushed Clear by Alumet Supply <br /> BACKS: .090 alum. backs-insides painted w/White Light Enhancement paint <br /> DESIGN LOADS: ILLUM.: Agilight White LED illumination as required by manufacturer or approved equivalent <br /> 7'-7-3/8" RISK <br /> MPH WIND LOAD Power supplies housed within cabinet at same end near access panels <br /> 7'-6-3/8" RISK CATEGORY II, EXPOSURE C. pp <br /> 2021 INTERNATIONAL BUILDING <br /> 161-011 CODE, ASCE 7-16 <br /> OAH QUANTITY: (1) One Pylon required AREA/WEIGHT <br /> 15-1/2 THE LOCATION OF THE DISCONNECT SWITCH <br /> BUTT SEAM AFTER INSTALLATION SHALL COMPLY WITH <br /> SIGN SQUARE FOOTAGE: <br /> —--- ARTICLE 1(1)OF THE NATIONAL 29.7 s . ft. <br /> 12'-6-3/8" ELECTRIC CODE. ESTIMATED SIGN WEIGHT: <br /> FIELD VERIFICATION IS REQUIRED FOR ALL STRUCTURAL STEEL SPECIFICATIONS: 600 Lb. <br /> GROUND SIGNS TO ENSURE THAT THE <br /> RECOMMENDED SIGN WILL FIT IN THE SUPPORT MEMBERS SHALL BE FREE FROM DEFECTS. TUBE SHALL <br /> RECOMMENDED LOCATION,TAKING INTO MEET ASTM A PIPE GRADE B, T A A MINIMUM HELD STRENGTH NI COLOR PALETTE <br /> 46000 PSI. PIPE SHALL MEET ASTM MINIMUM <br /> GRADE B,WITHTHE A MINIMUM <br /> ACCOUNT ALLSET-BACKS,OBSTRUCTIONS, YIELD STRENGTH OF 35000 PSI.PLATE AND ANGLE SHALL MEET <br /> UNDERGROUND UTILITIES,ETC. ASTM A36. <br /> IF A PROBLEM IS DETECTED BY THE FIELD STRUCTURAL BOLTS SHALL BE ZINC COATED A325 UNLESS <br /> 5'-01 5'-011 VERIFICATION,ANIFRSHOULDBE OTHES SHALL <br /> NOTED. <br /> SUBMITTED FOR MODIFICATION BY MONIGLE WELDS SHALL C MADE WITH NTH <br /> A ELECTRODES BY PERSONS Matthews Garbo Silver 3M 3630-8530 Blue <br /> QUA WO YEARS. <br /> E D IN ACCORDANCE W1TH AWS STANDARDS VATHIN THE PAST <br /> STALLL NEW SIGN GEOUSNG MANUFACTURING. <br /> XIS ING PR IM RY RENF RCING BARS SHALL CONFORM TO ASTM A615 GRADE 60 WITH MP02650R14405 LVG Full gloss w/Overlam 3M 3660M <br /> ELECTRICAL. DEFORMATIONS IN ACCORDANCE WITH ASTM A-305. WELDING OF <br /> VERIFY IF ADDITIONAL CIRCUITS ARE REQUIRED REINFORCING BARS IS PROHIBITED. <br /> 6NCHR BOLTS SHALL BE ASTM F1554-07 GRADE 55 ROUND STOCK. <br /> FOR NEW SIGN. EXPOSED SURFACES SHALL BE GALVANIZED OR HAVE BITUMINOUS <br /> RESTORE GROUND MATERIAL TO BASE OF NEW SIGN. COATING TO PREVENT CORROSION. Matthews Red MP49696 Aluminum Coil-Brite Brushed <br /> PROTECT ANCHOR BOLTS, THIS SIGN TO BEAR THIS MARK THIS SIGN IS INTENDED TO BE INSTALLED Q Akzo Nobel Sign 20129 O Clear by Alumet Supply <br /> NUTS, AND WASHERS SIGN TO BE B.L.LISTED INACCORDANCE WITH THE REQUIREMENTS OF <br /> FROM CORROSION WITH AND SHALL MEET N.E.C.STANDARDS ARTICLE 6D00F THE NATIONAL ELECTRICAL <br /> 3M 3630-2413 Red <br /> BITUMINOUS COATING CODE ANDIC OTHER APPLICABLE LOCAL CODES. <br /> OOntlerwtltc. <br /> els THIS INCLUDES PROPER GROUNDING&BONDING OF SIGN. w/Overlam 3M 3660M O ALUCOBOND 4mm <br /> LaboratorieFRONT VIEW SIDE VIEW L ELECTRIC <br /> SIIG NOTE 1 SIGN IS THHNPO BE REDWITH 14 GAGE AMONSALLASTSTRANDED <br /> I n USE WHITE SILICONE TO ELECTRIC SIGN tCALAL LEADSTOBE14GAGESMID600VWIR Natural Brushed 50ACM <br /> ELEHHN <br /> 3-7-5/8 MPe SIGN el UST BE(GROUNDED WITH <br /> AGE SOLID <br /> GREEN <br /> WIRE <br /> CONCEAL LIGHT LEAKS SIGN MUST BEGROUNDEDWITH I4 GAGE SOLID 600VGREEN WIRETHHN <br /> 4'-3-3/8" LOCATE UL LABEL ONLOWER CORNER OF CLADDING BEHIND SIGN FACE <br /> CLIENT: ORDER NUMBER: PROJECT NUMBER: Rev# Req# Date/Artist Description Rev# Req# Date/Artist Description <br /> o �� 1212772 4306 Original 476996 05/22/24 SV <br /> BANK OF A M E R I C A " Rev 1 479662 06/06/24 SV Added Engineering Tag.Adjusted measurements to match <br /> SITE NUMBER: PROJECT MANAGER: Rev 486566 07/24/24DB Changed to Custom A2-HWn 16'-0"OAH,added tag <br /> ADDRESS: PAGE NO.: 18031 Michele Homer <br /> _ . 1803 112th St SE ELECTRONIC FILE NAME: <br /> • . ,•.• Everett,WA 98202 11 K:IA000UNTSIBIBANK OF AMERICA120241WA118031_Everettl <br /> as 4306 18031 Everett R2.cdr e e . •.• • <br />