My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1000 SE EVERETT MALL WAY EXTERIOR BASE FILE 2025-10-22
>
Address Records
>
SE EVERETT MALL WAY
>
1000
>
BASE FILE
>
1000 SE EVERETT MALL WAY EXTERIOR BASE FILE 2025-10-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/22/2025 10:26:01 AM
Creation date
10/13/2025 9:23:06 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1000
Unit
EXTERIOR
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project: Everett Mall Canopy Job Number: 23-695 <br />mXFCS Sheet: of Name: LAE <br />Structural Solutions Originating Office: Tacoma Date: 09/27/21 <br />DESIGN CRITERIA - SEISMIC <br />ASCE 7-16 SECTION 12.8 - EQUIVALENT LATERAL FORCE PROCEDURE <br />RISK CATEGORY: <br />II <br />LATITUDE: <br />47.910 <br />SITE CLASS: <br />D <br />LONGITUDE: <br />-122.219 <br />IMPORTANCE FACTOR (IE): <br />I <br />Ss = <br />1.362 <br />STRUCTURAL SYSTEM (R): <br />3.5 <br />St = <br />0.483 <br />OVERSTRENGTH FACTOR (Q.): <br />3 <br />Fa = <br />1.200 <br />F� = <br />2.000 <br />ASCE 7-16 SECTION 11.4 SEISMIC GROUND MOTION VALUES <br />Section 11.4.4 - Coefficients and Risk -Targeted Maximum Considered Earthquake (MCER) Spectral Response Acceleration Parameters <br />Sluts = Fa*Ss = 1.634 Sm, = Fv*St = 0.966 <br />Section 11.4.5 - Design Spectral Response Acceleration Parameters <br />SDS = 2/3*SMs = 1.090 SDI = 2/3*SMt = 0.644 <br />ASCE 7-16 SECTION 11.6 - SEISMIC DESIGN CATEGORY - SECTION 12.8.2 - PERIOD DETERMINATION <br />ASCE 7-16 TABLE 11.6-1 <br />SEISMIC DESIGN CATEGORY BASED ON SDs <br />RISK CATEGORY: <br />I & II <br />III <br />1V <br />< 0.167g <br />A <br />A <br />A <br />< 0.33g <br />B <br />B <br />C <br />< 0.50g <br />C <br />C <br />D <br />>= 0.50g <br />D <br />D <br />D <br />D <br />ASCE 7-16 TABLE 11.6-2 <br />SEISMIC DESIGN CATEGORY BASED ON SDI <br />RISK CATEGORY: <br />I & II <br />III <br />IV <br />< 0.067g <br />A <br />A <br />A <br />< 0.133g <br />B <br />B <br />C <br />< 0.20g <br />C <br />C <br />D <br />>= 0.20g <br />D <br />D <br />D <br />D <br />ASCE 7-16 SECTION 12.8.1.1 - SEISMIC RESPONSE COEFFICIENT <br />GENERAL EQUATION <br />CS = SDS/(R/I) = <br />CS = 1.5*SD1/(T*(R/1)) = <br />MINIMUM: Cs = 0.044*SDs*I > 0.01 = <br />For structures located where S 1 > 0.6g <br />CS = 0.5*Sl/(R/1) = <br />ASCE 7-16 SECTION 12.8.1 - SEISMIC BASE SHEAR <br />Each building and structure shall <br />be assigned to the most severe <br />Seismic Design Category in <br />accordance with Table 11.6-1 or <br />Table 11.6-2, irrespective of the <br />fundamental period of vibration of <br />the structure. <br />PERIOD DETERMINATION: <br />Cl = 0.02 <br />k = 50 FT <br />x = 0.75 <br />Ta = Ct*h„" = 0.376 <br />0.311 <--CONTROLS EQ.12.8-2 <br />0.734 EQ. 12.8-3 <br />0.048 EQ. 12.8-5 <br />0.000 EQ. 12.8-6 <br />V = Cs*W = 0.311*W W = the total dead load and applicable portion of other loads as <br />indicated in Section 12.7.2 <br />Design Criteria - IBC2018 - Revised 04/12/21 23695 Design Criteria 2023-09-27 lah(Earthquake) <br />
The URL can be used to link to this page
Your browser does not support the video tag.