Existing General Notes <br />Information <br />SENEF,AL 67RUCTURAL NOTE5 <br />Structural design is in accordance with the 1982 UBC. Submit complete shop drawings for rein- <br />forcing steel, Structural Steel, Hambro Joists, Taftrus Girders, Open Web Joists and Girders. <br />All concrete and structural steel members shall be inspected by an approved Testing Lab <br />during construction. <br />LOADS <br />Roof Live Load = 25 psf <br />Office Floor Live Load = 50 psf + 20 psf Partition <br />Corridor & Stair Live Load =100 psf <br />Wind = 20 Dsf <br />Seismic Zone III k = .67 <br />Allowable Soil Bearing = 6000 psf for till <br />Equivalent fluid pressure = 55 pcf <br />C0NrRFTF. <br />Footings, walls, piers, slabs fC = 3000 psi at 28 days, submit design mix for <br />MAX, adC4*i_S&TE StZa iN 3' Kaz* 4Ls195 < �„ approval. <br />Reinforcing steel - Grade 60 except bent dowels shall be Grade 40. <br />All reinforcing shall be detailed in accordance with ACI Detailers Manual. Provide corner <br />bars to match all horizontal reinforcing. <br />Lap all bars minimum of 36 bar diameters. Provide 245 all around wall openings unless shown <br />otherwise. Provide footing dowels to match vertical reinforcing. All welded reinforcing to <br />be Grade 40. <br />Clearance to Reinforcing: <br />Footings 3" cover <br />Piers, Concrete walls -exposed to soil-1 112" cover <br />STRUCTURAL STEEL GONT96GTcw_ 0UAJN6 GdH6 iCH <br />UNTIL ALL FPA Me vv6LD4 oRKtCVMftTS eL ,*4.RA7pr PW- 1lelrf RAce- <br />Open Web joists shall conform with Steel Joist Institute specifications. Camber alI joists <br />for dead load. Provide 2" minimum weld on each side of bearing seat. <br />Camber all wide flange beams for Dead Load. <br />Structural shapes & Miscellanious steel - A-36 (Fy=36,000 psi). See sheet S-} for additional <br />notes for Momemt Frames. <br />Structural tubing ASTM A500, Grade B. Fy = 46,000 psi <br />All column baseplates to be rolled steel plates up to 2" thick. Mill bearing surfaces over <br />2" thick plates. <br />Bolts - A 325F. Provide 3/4" 0 x 2-112 end welded studs at 21-0" o.c. to all .floor beams at <br />centerline beam unless shown otherwise. TF0JrJt Lib, iW,?2GTGR. *A.L.L. JNW5GT- ALL PIry <br />DCL4r, Tb l HeaL RB C01 PL.I o NcE \vf l"4 AIAiG �h FM AhTM 32S p .fi3 <br />Welding - E 70xx electrodes. All welding shall be performed by certified welders. All <br />welded joints at Frames 1 through 7 shall be inspected by Ultrasonic testing. Also field <br />welded moment connections at cantilevered beams shall be tested. <br />1-112" Metal roof deck shall be minimum'2 span Type B conforming ASTM A611,_galvanized with <br />light commercial coating. Minimum end lap of sheets to be 211. Weld to supports as shown <br />on plans. <br />The Hambro joists and Taftrus open web girders shall be fabricated and installed in accordance <br />aiiLL.the Manufacturera_approyed published specifications and recommendatiops. Provide randomly <br />spaced X bridging as required to reduce floor vibration. <br />FOUNDATION <br />All footings shall bear on the very dense, gray glactial till found at depths of approximately <br />5 feet below existing grade. <br />Fill placed beneath slab areas shall be compacted in 12 inch lifts to 909E density (ASTM:D-1557) <br />See Soils report by Rittenhouse -Zeman and Associates for complete recommendations regarding <br />the foundation, site soils and drainage. <br />