My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1000 SE EVERETT MALL WAY EXTERIOR BASE FILE 2025-10-22
>
Address Records
>
SE EVERETT MALL WAY
>
1000
>
BASE FILE
>
1000 SE EVERETT MALL WAY EXTERIOR BASE FILE 2025-10-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/22/2025 10:26:01 AM
Creation date
10/13/2025 9:23:06 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1000
Unit
EXTERIOR
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Title: <br />Engineer: <br />Project ID: <br />Project Descr: <br />Steel Beam <br />LIC# : KW-06014122, Build:20.23.08.30 PCS STRUCTURAL SOLUTIONS <br />DESCRIPTION: North Canopy: BM 2 - Cantilever option <br />CODE_ REFERENCES <br />Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16 <br />Load Combination Set: IBC 2021 <br />Material Properties <br />Analysis Method Allowable Strength Design <br />Beam Bracing: Completely Unbraced <br />Bending Axis: Major Axis Bending <br />1)(0.12 ) S(O.20 <br />W 12x35 <br />Span - 16.0 ft <br />Project File: Everett Mall Canopy.ec6 <br />(c) ENERCALC INC 1983-2023 <br />Fy : Steel Yield: 50.0 ksi <br />E: Modulus: 29,000.0 ksi <br />Applied Loads Service loads entered. Load Factors will be applied for calculations. <br />Beam self weight NOT internally calculated and added <br />Uniform Load : D = 0.0150, S = 0.0250 ksf, Tributary Width = 8 0 ft <br />DESIGN SUMMARY <br />Maximum Bending Stress Ratio = <br />Section used for this span <br />Ma: Applied <br />Mn / Omega: Allowable <br />Load Combination <br />Span # where maximum occurs <br />Maximum Deflection <br />Max Downward Transient Deflection <br />Max Upward Transient Deflection <br />Max Downward Total Deflection <br />Max Upward Total Deflection <br />0.496 : 1 <br />Maximum Shear Stress Ratio = <br />W12x35 <br />Section used for this span <br />40.960 k-ft <br />Va : Applied <br />82.594 k-ft <br />Vn/Omega : Allowable <br />+D+S <br />Load Combination <br />Location of maximum on span <br />Span # 1 <br />Span # where maximum occurs <br />0.343 in Ratio = <br />1,118 <br />>=360 Span: 1 : S Only <br />0 in Ratio = <br />0 <br /><360 n/a <br />0.549 in Ratio = <br />699 <br />>=180 Span: 1 : +D+S <br />0 in Ratio = <br />0 <br /><180 n/a <br />Maximum Forces & Stresses for Load Combinations <br />0.068 <br />W12x35 <br />5.120 k <br />75.0 k <br />+D+S <br />16.000 ft <br />Span # 1 <br />Load Combination <br />Max <br />Stress <br />Ratios <br />Summary of MomefifVaTu-es <br />ummary of Shear-VaIu-es <br />Segment Length <br />Span # <br />M <br />V Mmax + <br />Mmax - <br />Ma Max <br />Mnx Mnx/Omega Cb Rm <br />Va Max <br />VnxVnx(Omega <br />DOnly <br />- --- <br />--- <br />Dsgn. L = 16.00 ft <br />1 <br />0.186 <br />0.026 <br />-15.36 <br />15.36 <br />137.93 <br />82.59 1.00 1.00 <br />1.92 <br />112.50 75.00 <br />+D+S <br />Dsgn. L = 16.00 ft <br />1 <br />0.496 <br />0.068 <br />-40.96 <br />40.96 <br />137.93 <br />82.59 1.00 1.00 <br />5.12 <br />112.50 75.00 <br />+D+0.750S <br />Dsgn. L = 16.00 ft <br />1 <br />0.418 <br />0.058 <br />-34.56 <br />34.56 <br />137.93 <br />82.59 1.00 1.00 <br />4.32 <br />112.50 75.00 <br />+0.60D <br />Dsgn. L = 16.00 ft <br />1 <br />0.112 <br />0.015 <br />-9.22 <br />9.22 <br />137.93 <br />82.59 1.00 1.00 <br />1.15 <br />112.50 75.00 <br />Overall Maximum Deflections <br />Load Combination <br />Span Max. " " Defl Location in Span <br />Load Combination <br />Max "+^ Dell Location in Span <br />+D+S <br />1 <br />0.5491 <br />0.000 <br />0.0000 <br />0.000 <br />Vertical Reactions <br />Support notation : <br />Far left is # <br />Values in KIPS <br />Load Combination <br />Support 1 Support 2 <br />Max Upward m all Load Conditions <br />5.120 <br />Max Upward from Load Combinations <br />5.120 <br />Max Upward from Load Cases <br />3.200 <br />D Only <br />1.920 <br />+D+S <br />5.120 <br />+D+0.750S <br />4.320 <br />+0.60D <br />1.152 <br />
The URL can be used to link to this page
Your browser does not support the video tag.