My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1000 SE EVERETT MALL WAY EXTERIOR BASE FILE 2025-10-22
>
Address Records
>
SE EVERETT MALL WAY
>
1000
>
BASE FILE
>
1000 SE EVERETT MALL WAY EXTERIOR BASE FILE 2025-10-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/22/2025 10:26:01 AM
Creation date
10/13/2025 9:23:06 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1000
Unit
EXTERIOR
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
113PCS <br />Structural Solutions <br />Project: Everett Mall Canopy Job Number: <br />Sheet: of <br />Originating Office: Tacoma <br />DESIGN CRITERIA CHECKLIST <br />Name: <br />Date: <br />23-695 <br />LAH <br />9/27/2021 <br />CODE: IBC 2018, ASCE 7-16 1 LOCATION: Everett, WA <br />RISK CATEGORY: li (Per ASCE 7-16 Table 1.5-1 & IBC Table 1604.5) <br />VERTICAL DESIGN CRITERIA <br />DEAD LIVE PARTITION CONCENTRATED <br />WIND DESIGN CRITERIA <br />BASIC WIND SPEED (V) = <br />98 MPH <br />(Per ASCE 7-16 Sec. 26.5.1, Fig. 26.5-1A; 1B; 1C & 1D, or as required by Bldg Dept.) <br />EXPOSURE CATEGORY: <br />B <br />(Per ACSE 7-16 Section 26.7.3) <br />DIRECTIONALITY FACTOR (Kd): <br />0.85 <br />(Per ASCE 7-16 Table 26.6-1) <br />GUST EFFECT FACTOR (G) <br />0.85 <br />(Per ASCE 7-16 Section 26.11) <br />TOPOGRAPHIC FEATURE: None <br />(See ASCE 7-16 Figure 26.8-1) <br />HILL HEIGHT (H): <br />100 FT <br />(See ASCE 7-16 Figure 26.8-1) <br />UPWIND DISTANCE TO HALF HILL (Lh): <br />100 FT <br />(See ASCE 7-16 Figure 26.8-1) <br />DISTANCE FROM CREST TO SITE (x): <br />100 FT UPWIND (See ASCE 7-16 Figure 26.8-1) <br />MEAN ROOF HEIGHT: So FT <br />(See ASCE 7-16 Section 26.2 - Definitions) <br />ELEVATION: <br />0 FT <br />(See ASCE 7-16 Section 26.9) <br />ENCLOSURE CLASSIFICATION: Enclosed <br />(See ASCE 7-16 Secion 26.2 & Table 26.13-1) <br />ROOF TYPE: Monoslope , (See ASCE 7-16 Figure 27.3-1) <br />ROOF SLOPE (_:12): 0.50:12 1 (Enter vertical rise in 12 horizontal units) 0 (degrees): 2.39 <br />SEISMIC DESIGN CRITERIA <br />SITE CLASS: D (Per IBC Section 1613.2.2, Assumed as "D" or per Geotech.) <br />IMPORTANCE FACTOR 00: 1 (Per ASCE 7-16 Table 1.5-2) <br />STRUCTURAL SYSTEM (R): 3.5 (Per ASCE 7-16 Table 12.2-1) <br />OVERSTRENGTH FACTOR (00): 3.0 (Per ASCE 7-16 Table 12.2-1) <br />INFORMATION BELOW FROM APPLIED TECHNOLOGY COUNCIL (ATC) "HAZARDS BY LOCATION" <br />LATITUDE: 47.9Ss = 1.362 Fa = 1.200 <br />LONGITUDE: 10122.219 S, = 0.483 Fv= 2.000 <br />DEFLECTION CRITERIA <br />FLOOR (LIVE): L/ 480 . ROOF (LIVE): L/ 360 n <br />FLOOR (TOTAL): L/ 360 F ROOF (TOTAL): L/ 240 <br />WALLS: L/ 360 _ SPECIAL: L/ n <br />SOIL DESIGN CRITERIA <br />REPORT: No <br />BEARING: 6000 PSF <br />ACTIVE: 35 PCF <br />PASSIVE: 250 PCF <br />COEFFICIENT OF FRICTION 0.35 <br />PILE TYPE: NONE <br />VERTICAL CAPACITY: N/A <br />Design Criteria - IBC2018 - Revised 0 <br />Values provided in existing drawings <br />MINIMUM FOOTING DIMENSIONS: <br />CONTINUOUS: <br />SPREAD: P-6" <br />FROST DEPTH: F-6" <br />LATERAL CAPACITY: I N/A <br />23695 Liesign Criteria 3-09-27 lah(Overall (Input)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.