My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2520 100TH ST SE 2025-11-07
>
Address Records
>
100TH ST SE
>
2520
>
2520 100TH ST SE 2025-11-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2025 1:39:35 PM
Creation date
10/13/2025 11:17:37 AM
Metadata
Fields
Template:
Address Document
Street Name
100TH ST SE
Street Number
2520
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 5 MUST BE COMPLETED BY THE BUILDING DEPARTMENT IN THE JURISDICTION THE HOME WILL BE LOCATED. <br /> PLEASE CHECK ALL APPLICABLE BOXES; MATCH THE LIST BELOW TO THE APPLICANT'S FLOOR PLAN—USING THEIR PROSPECTIVE <br /> RESIDENT BEDROOM DESIGNATIONS OF A BCD E AND FAN CLASSIFICATION CODES, NS1 OR NS2. <br /> *Please make copies of this bedroom page if the home has more than six resident bedrooms to be inspected. <br /> SECTION • • INSPECTION <br /> R330.3 Sleeping Room Classification: Each sleeping room in an Adult family Home shall be classified as: <br /> Type S—where the means of egress contains stairs,elevators or platform lifts to evacuate residents to public area. <br /> Type NS1-where 1 means of egress at grade level (has no stairs) or ramp constructed compliant with R330.9 is provided to evacuate <br /> residents to public area. <br /> Type NS2—where 2 means of egress at grade level (both have no stairs)or ramps constructed compliant with R330.9 are provided to <br /> evacuate residents to public area. <br /> SLEEPING ROOM A OType S OType NS1 OType NS2 YES NO <br /> Closet door/s are readily openable from the inside 0 Yes I 0 No I ON/A Smoke alarm is installed in the bedroom 0 0 <br /> Bedroom door opens easily and quickly from the outside when locked 0 0 <br /> Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high;at least 20"wide) 13 13 <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor to clear opening; no steps under window allowed 13 13 <br /> SLEEPING ROOM B OType S OType NS1 OType NS2 YES NO <br /> Closet door/s are readily openable from the inside 0 Yes I 0 No ON/A Smoke alarm is installed in the bedroom 13 <br /> Bedroom door opens easily and quickly from the outside when locked 13 0 <br /> Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) 13 0 <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor to clear opening; no steps under window allowed 0 0 <br /> SLEEPING ROOM C OType S OType NS1 OType NS2 YES NO <br /> Closet door/s are readily openable from the inside 0 Yes 0 No I ON/A Smoke alarm is installed in the bedroom 0 0 <br /> Bedroom door opens easily and quickly from the outside when locked 0 0 <br /> Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high;at least 20"wide) 0 0 <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor to clear opening; no steps under window allowed <br /> SLEEPING ROOM D 0 Type S P Type NS1 [3 Type NS2 YES NO <br /> Closet door/s are readily openable from the inside 0 Yes 0 No ON/A Smoke alarm is installed in the bedroom 13 13 <br /> Bedroom door opens easily and quickly from the outside when locked 13 13 <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) 13 13 <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed [3 0 <br /> SLEEPING ROOM E OType S PType NS1 [3Type NS2 YES NO <br /> Closet door/s are readily openable from the inside 0 Yes 0 No ON/A Smoke alarm is installed in the bedroom <br /> Bedroom door opens easily and quickly from the outside when locked 13 13 <br /> Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) 13 0 <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor to clear opening; no steps under window allowed 0 0 <br /> SLEEPING ROOM F OType S OType NS1 OType NS2 YES NO <br /> Closet door/s are readily openable from the inside 0 Yes 0 No ON/A I Smoke alarm is installed in the bedroom 0 0 <br /> Bedroom door opens easily and quickly from the outside when locked 0 0 <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) 0 0 <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor to clear opening; no steps under window allowed 13 13 <br /> Implementation Date: 2024 March 15 <br /> Updated: 2024 March <br />
The URL can be used to link to this page
Your browser does not support the video tag.