My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3015 9TH ST BLDG 4 2025-11-06
>
Address Records
>
9TH ST
>
3015
>
BLDG 4
>
3015 9TH ST BLDG 4 2025-11-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/6/2025 11:22:04 AM
Creation date
10/13/2025 3:17:47 PM
Metadata
Fields
Template:
Address Document
Street Name
9TH ST
Street Number
3015
Tenant Name
BLDG 4
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Doug Hofius <br /> Dykeman Architects <br /> Plan Check Number: B2211-013, First Building Review <br /> December 16, 2022 <br /> Architectural <br /> 1. The project includes work on the exterior envelope of the building. The RCW 64.55 form <br /> should be completed and submitted with the application. Additional documentation as required <br /> by the form should be submitted for review. <br /> 2. Sheet CS1.00 lists the Construction Type as "IV-A". The building is anticipated to be Type"V- <br /> A". See IBC Table 601. <br /> 3. The drawings should specify if the building is sprinklered or non-sprinklered. See IBC Sections <br /> 107.2.1 and 903. <br /> 4. Roof Type "W1103" references listing "GA RC 2602"and specifies insulation directly above the <br /> GWB. This listing does not include insulation. Insulation is not permitted as shown per the GA <br /> notes. A revised tested assembly with the required insulation should be specified. See IBC <br /> Section 703.2. <br /> 5. The construction drawings should include ceiling plans. It is anticipated that the work requires <br /> the replacement of exhaust fans. Bath fans may include radiation dampers per IBC Section <br /> 717.6.2. Other ducts that cannot include dampers, including kitchen hoods, are required to be <br /> located in fire-rated chases or soffits below the horizontal assemblies. Details should be <br /> included. See IBC Section 107.2.1. <br /> 6. The ceiling plans should specify fire alarms. See IBC Sections 107.2.1 and 907.2.10.2. <br /> 7. Details for membrane penetrations should be included in the drawings. See IBC Sections 714.4 <br /> and 714.5. <br /> Structural <br /> 1. The project includes repair of damaged structure including but not limited to the floor, bearing <br /> walls, and roof including the trusses. Structural drawings signed by a professional engineer <br /> licensed in the state of Washington are required. Calculations substantiating the repairs should <br /> be included in the structural design package. See RCW Sections 18.43.010, 18.473.020, and <br /> 18.43.070. <br /> 0 3200 Cedar Street © 425.257.8810 O everetteps@everettwa.gov <br /> Everett, WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.