Laserfiche WebLink
Installation Programming <br /> The timer dial contains 72 "trippers" which, when set <br /> 1. Read the operating instructions carefully. at the inner perimeter of the dial, will turn the switch <br /> 2. Check the input and output ratings marked on the "ON" at the time adjacent to the tripper. The switch will <br /> return to the "OFF" position when the timer progresses <br /> unit to make sure this product is suitable for your past the inward trippers. <br /> application. The 72 trippers allow multiple on/off sequences with a <br /> 3. Disconnect power supply prior to installation to pre- minimum on or off time of 20 min. To program, set all <br /> vent electrical shock. trippers inward for the duration of the on event. <br /> 4. Damage to the contacts caused by short circuiting For example, to turn lights on at 5:00pm and off at <br /> will void warranty. 11:00pm, leave inward the 18 trippers between 5 and <br /> 5. Wire in accordance with National and local electri- 11 on the "pm" side of the dial. Make sure manual <br /> cal code requirements. switch is in the+.`_..position. <br /> BE SURE ALL CONNECTIONS ARE SECURE. NOTE: For any times where "OFF" programming <br /> DOUBLE CHECK ALL TWIST-ON WIRE CON- is desired, the trippers must be moved to the outer <br /> NECTORS. perimeter of the dial. <br /> 6. Mount timer into wall box using supplied screws. <br /> 7. If timer does not operate, check that the timer's black Setting The Time <br /> wire is connected to hot line and not the load. If nec- Rotate the dial clockwise until the correct time and <br /> essary, reverse connections to red and black wires. "am" or "pm" is opposite the arrow on the plate. <br /> CAUTION: Do not turn dial counter-clockwise, as the <br /> Manual Operation timer will be damaged. <br /> The slide switch provides manual operation of the <br /> load, overriding the timer. If set to the t_} position, the ONE YEAR WARRANTY <br /> load will be continuously off, and if set to , it will be <br /> continuously on. For automatic timed on s and offs, <br /> If this unit fails due to a defect in material or workman- <br /> the switch must be in the s- position. ship within one year after purchase, Intermatic will repair <br /> or replace the unit free of charge. This warranty does not <br /> apply to damage due to accidents, abuse, mishandling <br /> nor to units not used in accordance with directions. This <br /> warranty gives you specific legal rights,and you may also <br /> have other rights which vary from state to state. <br /> Wiring Diagrams <br /> Standard Installation 3-Way Installation <br /> 0 0 <br /> LOAD HOT(BLACK) 3-Way switch <br /> HOT(BLACK} LOAD(RED} ) (RED) <br /> NEUTRAL(WHITE) NEUTRAL(WHITE) (BLUE) <br /> LOAD <br /> INTERMATIC INCORPORATE© Distributed by: <br /> Spring Grove, IL 600131 -969B <br /> www.intermatio.com <br /> a <br /> M <br /> 0 <br /> q <br />