CLIENT: <br /> VCASR <br /> &ASSOCIATES SEISMIC ANALYSIS PROJECT:H I T E C T S PER IBC 2018 DATE: <br /> NAME: <br /> Weight of Building: <br /> Roof Assembly: <br /> Asphalt Shingles - 2.00#/ft Cedar Shakes - 2.26#/ft Tile - 9.50#/it <br /> Felt - 0.15 #/ft Felt - 0.15 #/ft Felt - 0.15 #/ft <br /> 1/2" Plywood - 1.60 #/ft 1/2" Plywood. - 1.50 #/ft 1/2" Plywood - 1.60 #/ft <br /> Trusses ® 24" o.c. - 1.76 #/ft Trusses ® 24" o.c. - 1.76 #/ft Trusses ® 24" o.c. - 1.76 #/ft <br /> R-38 Insulation - 2.35#/it R-30 Insulation - 2,26#/ft R-30 Insulation - 2.25#/ft <br /> 1/2" GWB Ceiling - 2.00#/ft 1/2" GWB Ceiling - 2,00#/ft 1/2" GWB Ceiling - 2.00#/ft <br /> Total 9.75#/ft Total 9.90#/ft Total 17.90#/ft <br /> Use 10.00#/ft Use 10.00#/ft Use 18.00#/ft <br /> i <br /> Si <br />{ <br /> i <br /> 1st & 2nd Floor Assembly: <br /> Careet / Pad - 0.60#/ft Hardwood - 2.60#/It <br /> 3/4 T&G Plywood - 2.60#/ft 3/4" T&G Plywood - 2.50#/ft <br />' 2x10 ® 16" o.c. - 2.30#/ft 2x10 ® 16" o.c. - 2.30#/ft <br /> 1/2" GWB Ceiling - 2.00#/ft 1/2" GWB Ceiling - 2.00#/ft <br /> Total 7.30#/ft Total 9.30#/ft <br /> Use 10.00#/ft Use 10.00#/ft <br /> ri <br /> E: <br /> Interior Wall Assembly: Exterior Wall Assembly: <br /> 1/2" GWB - 2.00#/ft 3/4" Wood Siding - 2.30#/ft <br /> 2X4 ® 16" o.c. - 1.10 #/ft 1/2" Plywood - 1,50 #/ft <br /> 1/2" GWB - 2.00#/!t 2xe ® 16" o.c. - 1,37 #/ft <br /> R-21 Insulation - 2.10 ft <br /> Total 5.10 #/ft i/2" GWB - 2.00 /ft <br /> Use 8.00#/ft <br /> Total 9.27#/ft <br /> Use 10.00#/ft <br /> 4" Brick Veneer - + 3.20#/ft <br /> i <br /> i <br /> 8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117 <br /> WWW.NASH-ARCHITECTS.CGM <br />: <br />