Laserfiche WebLink
7 <br /> CI.IE M. <br /> WA <br /> &ASSOCIATES SEISMIC ANALYSIS PROJECT: <br /> HITECTS PER IBC 2010 DATE: <br /> • NAME: <br /> Weight of Building: <br /> Roof Assembly: <br /> Asphalt Shingles - 2.00#/ft Cedar Shakes - 2.25#/ft Tile - 9.50#/ft <br /> Felt <br /> Plywood - 0.15 #/ft Felt - 0.15 #/ft Felt -- 0.15 ft <br /> Trusses®24" o.c. - 1.1.50 #/ft 1/2 Plywood 1.50 #/ft 1/2" Plywood - 1.60#/ft <br /> #/ft Trusses ® 24 o.c. - 1.75 #/ft Trusses ® 24" o.c. - 1.75#/ft <br /> R-38 Insulation - 2.35#/ft R-30 Insulation - 2.25#/ft R-30 Insulation - 2.25#/ft <br /> 1/2" GWB Ceiling -- 2.00#/ft 1/2" GWB Ceiling - 2,00#/ft 1/2" GWB CeilingTot -- 2.00#/ft <br /> Use 9.75#/it Total 9.90#/ft Total 17.90#/ft <br /> 10.00#/ft Use 10.00#/ft Use I8.00#/ft <br /> lot & 2nd Floor Assembly. <br /> Caret / Pad - 0.50#/ft Hardwood - 2.50#/ft <br /> 3/4' T&G Plywood - 2.50#/ft 3/4" T&G Plywood - 2.50#/ft <br /> 2x10 ® 16" o.c. - 2.30#/ft 2x10 ® 16" o.c. - 2.30#/ft <br /> 1/2" GWB Ceiling - 2.00#/ft 1/2" GWB Ceiling - 2.00#/ft <br /> Total 7.30#/ft Total 9.30 ft <br /> Use 10.00#/ft Use 10.00#/ft <br /> Interior Wall Assembly: Exterior Wall Assembly: <br /> 1/2" GWB -- 2.00#/ft 3/4" Wood Siding - 2.30 <br /> #/ft <br /> 2X4 ® 16" o.c. - 1.10 <br /> #/ft 1/2" Plywood _ 1.50 #/ft <br /> 1/2- GWB - 2.00#/ft 2x6 ® 16" o.c. - 1.37 #/ft <br /> Total 5.10 #/ft R-21 Insulation - 2.10 /ft <br /> Use 8.00#/ft 1/2" GWB - 2.00#/ft <br /> Total 9.27#/ft <br /> Use 10.00#/ft <br /> 4" Brick Veneer - + 3.20#/ft <br /> 8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117 <br /> WWW.NASH-ARCHITECTS.COM <br />