Laserfiche WebLink
Mr. Rakeeb Khan <br /> October 26, 2022 <br /> Page 3 <br /> R312.1. The guards, connections to the supporting framing, and the supporting framing should <br /> be designed to resist a minimum 200-pound load per Table R301.5. <br /> Standard deck post connection detail added to the supplemental details. <br /> 5. The structural calculations do not include calculations for the lateral design of the covered <br /> deck. <br /> Calculations substantiating the design should be submitted for review. Lateral loads should be <br /> transferred to the ground or to a structure capable of transmitting them to the ground. See <br /> Section R507.9.2 for more information. R301.1.3 <br /> Lateral anchor callout added to plan view and detail added to the supplemental details in <br /> accordance with IRC Section R507.9.2 <br /> 6. Details of the gable end roof condition should be provided. Detail should specify bracing <br /> requirements to resist out-of-plane loading (e.g., wind) on the wall if the wall is not continuous <br /> between the floor and roof sheathing. This is not provided by the manufacturer. Note that <br /> truss stability bracing provided by the manufacturer is not intended for this purpose. See <br /> Sections R106.1.1 and R602.3. <br /> Supplemental structural details added including the gable end wall bracing <br /> 7. Structural special inspections may be required for this project (shear wall nailing closer than <br /> 4 inches). A statement on special inspections has not been provided and should be provided on <br /> the plans. The statement should include a table listing each type of special inspection and <br /> should specify the extent of each inspection (e.g., continuous, periodic) per IBC Section <br /> 1704.3.1. The table should include special requirements for seismic and wind resisting systems <br /> as required by IBC Sections 1704.3.2 and 1704.3.3, respectively. See IBC Sections 107.1, <br /> 1704.2.3, 1704.3, Table 1705.3. <br /> Structural notes, fastener schedule, and special inspection tables added to the end of the planset <br /> like i n f h i m in mor detail or if you <br /> Please feel free to contact me if you would a to discuss any o these to s e <br /> have any questions. You can reach me by phone at(206) 914-9536, or by email at <br /> LakeviewSE@outlook.com. <br /> I <br /> Sincerely, <br /> 4-0 <br /> 11/09/22 11:01 AM <br />