Laserfiche WebLink
PLAN 17+/q <br /> BEDROOM#2 <br /> RS-1 <br /> SelCcljon 4x 8 DF-L#2 Lu=0.0 Ft <br /> Conditions NDS 2005 <br /> Min Searing Area R1=2.6 W R2=2.O W (1.5)DL Deft= 0.03 in <br /> DDate, Beam Span 5.0 ft Reaction 1 LL 1095# Reaction 2 LL 1095# <br /> Beam Wt perlt 6.17# Reaction 1 TL 1765# Reaction 2 TL 1765# <br /> Bm Wt Included 310 Maximum V 1765# <br /> Max-Moment 2207 T Max V(Reduced) 1339# <br /> TL Max Deft L1240 TL Actual Defl L1904 <br /> LL Max Defl L 1380 LL Actual Deff L I>1000 <br /> t4ftdhutes Section kaD Shear(in') TL Dell(In) LL Deli <br /> Actual 30.66 25.38 0.07 0.03 <br /> Critical 22.63 11.16 0.25 0AT <br /> Status OK OK OK OK <br /> Ratio 740% 44% 27% 21% <br /> _Fb(psi� Fy(psi E(psi x mil) Fo►(psi)_ <br /> V._afues Reference Values 9DD 180 1.6 625 <br /> Adjusted Values 1170 160 1.6 625 <br /> Adjustments CF Size Factor . 1.300 <br /> Cd Duration 1.00 1.00 <br /> Cr Repetitive 1.00 <br /> Ch Shear Stress NIA <br /> Cm Wet Use 1,00 1.00 11.00 1.0D <br /> Cl Stability 1.0000 Fib=0.00 Le=0.00 Ft <br /> Loads Uniform LL:43B Uniform TL:700 =A <br /> Uniform toad A <br /> R1=1755 R2=1765 <br /> SPAN=5 FT <br /> Uniform and partial uniform loads are Ibs per lineal fL <br />