Laserfiche WebLink
The comments below were generated from this project's City of Everett Civil Reviewers.All questions shall be routed through this project's Public Works <br /> Reviewer Thad Newport with City of Everett Permit Services (TNewport@everettwa.gov). <br /> # Document Sht/Pg Reviewer's Comment Designer's Response Initials <br /> 1 Civil Plans — Planning Reviewer Comments (Jessica Jarvi): <br /> Chain link fencing is not permitted within the UR4 zone per EMC <br /> 19.40.020(C). Please specify fencing material in next submittal. <br /> 2 Civil Plans - Public Works Comments (Thad Newport): <br /> Fence must be setback a minimum of 1-foot from edge of alley <br /> paving. <br /> 3 Civil Plans - Structural Reviewer Comments (Cal Bearman): <br /> Guards should be provided for those portions of open-sided <br /> walking surfaces that are located more than 30 inches measured <br /> vertically to the floor or grade below at any point within 36 <br /> inches horizontally to the edge of the open side. See IBC 1015.2 <br /> Guards shall be designed to resist a linear load of 50 pounds per <br /> linear foot in accordance with Section 4.5.1.1 of ASCE 7. See IBC <br /> 1607.9.1 <br /> The minimum concentrated live load that the guard is required <br /> to support is 200 pounds. See IBC 1607.9.1.1 <br /> The guard height should be at least 42 inches high and opening <br /> limitation is that a 4-inch diameter sphere cannot pass through <br /> it. See IBC 1015.3 and IBC 1015.4 <br /> Page 2 of 2 <br />