My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5801 SEAHURST AVE 2025-12-12
>
Address Records
>
SEAHURST AVE
>
5801
>
5801 SEAHURST AVE 2025-12-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2025 10:48:07 AM
Creation date
10/17/2025 10:48:13 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAHURST AVE
Street Number
5801
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
174
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
For SI: 1 inch=25.4 mm, 1 foot=304.8 mm, 1 mile per hour=0.447 m/s; 1 ksi=6.895 MPa. <br /> 1. Nails are smooth-common,box or deformed shanks except where otherwise stated. Nails used for framing <br /> and sheathing connections shall have minimum average bending yield strengths as shown:80 ksi for shank <br /> diameter of 0.192 inch(20d common nail),90 ksi for shank diameters larger than 0.142 inch but not larger <br /> than 0.177 inch,and 100 ksi for shank diameters of 0.142 inch or less. <br /> 2. Staples are 16 gage wire and have a minimum 7/16-inch on diameter crown width. <br /> 3. Nails shall be spaced at not more than 6 inches on center at all supports where spans are 48 inches or <br /> greater. <br /> 4. Four-foot by 8-foot or 4-foot by 9-foot panels shall be applied vertically. <br /> 5. Spacing of fasteners not included in this table shall be based on Table R602.3(2). <br /> 6. Where the ultimate design wind speed is 130 mph or less, nails for attaching woad structural panel roof <br /> sheathing to gable end wall framing shall be spaced 6 inches on center.Where the ultimate design wind <br /> speed is greater than 130 mph,nails for attaching panel roof sheathing to intermediate supports shall be <br /> spaced 6 inches on center for minimum 48-inch distance from ridges,eaves and gable end walls;and 4 <br /> inches on center to gable end wall framing. <br /> 7. Gypsum sheathing shall conform to ASTM C 1396 and shall be installed in accordance with GA 253. <br /> Fiberboard sheathing shall conform to ASTM C 208. <br /> 8. Spacing of fasteners on floor sheathing panel edges applies to panel edges supported by framing members <br /> and required blocking and at floor perimeters only.Spacing of fasteners on roof sheathing panel edges <br /> applies to panel edges supported by framing members and required blocking. Blocking of roof or floor <br /> sheathing panel edges perpendicular to the framing members need not be provided except as required by <br /> other provisions of this code. Floor perimeter shall be supported by framing members or solid blocking. <br /> 9. Where a rafter is fastened to an adjacent parallel ceiling joist in accordance with this schedule,provide two <br /> toe nails on one side of the rafter and toe nails from the ceiling joist to top plate in accordance with this <br /> schedule.The toe nail on the opposite side of the rafter shall not be required. <br />
The URL can be used to link to this page
Your browser does not support the video tag.