Laserfiche WebLink
60 <br /> --- - <br /> WoodWorks@ Sizer SOFTWARE FOR WOOD DESIGN <br /> 2_11 Garage Header WoodWorks®Sizer 2019 (Update 4) Page 2 <br /> Additional Data: <br /> FACTORS: F/E (psi) CD CM Ct CL Ch Cfu Cr Cfrt Ci LC# <br /> Fv' 170 1.15 1.00 1.00 - - - - 1.00 1.00 2 <br /> Fb'+ 875 1.15 1.00 1.00 1.000 1.000 1.00 1.00 1.00 <br /> Fcp' 625 - 1.00 1.00 - - - 1.00 1.00 <br /> E' 1.3 million 1.00 1.00 - - -- 1.00 1.00 2 <br /> Emin' 0.47 million 1.00 1.00 - - - - 1.00 1.00 2 <br /> CRITICAL LOAD COMBINATIONS: <br /> Shear : LC 42 = D + S <br /> Sending(+) : LC 42 = D + S <br /> Deflection: LC 42 = D + S (live) <br /> LC #2 = D + S (total) <br /> Bearing Support 1 - LC #2 = D + S <br /> Support 2 - LC #2 = D + S <br /> D=dead S=snow <br /> All LC's are listed in the Analysis output <br /> Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1 <br /> CALCULATIONS: <br /> V max = 2120, V design = 1859 lbs; M(+) = 8480 lbs-ft <br /> EIy = 906.17 lb--in^2 <br /> "Live" deflection is due to all non-dead loads (live, wind, snow...) <br /> Total deflection = 1.0 dead + "live" <br /> Design Notes: <br /> 1.Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design <br /> Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement. <br /> 2. Please verify that the default deflection limits are appropriate for your application. <br /> 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. <br />