Laserfiche WebLink
Project Name <br /> Design Criteria and Loads KPFF Project No, 2300091 <br /> STRUCTURAL DESIGN AND SYSTEMS SUMMARY <br /> The ZAP Energy TI is located at an existing structure in Everett, WA. The original condition <br /> consists of warehouse and office space supported by wood, steel, and tilt-up concrete framing. <br /> Existing framing will be analyzed to support a new operable partition. Sawn lumber header and <br /> sill beams will be provided at locations of new windows at Level 2. A new interior steel stair will <br /> be supported on thickened slab-on-grade. <br /> CODES AND REFERENCES ::::;....... ..:.... <br /> • 2018 IBC Standards <br /> • Design Loads <br /> o ASCE/SEI 7-16, Minimum Design Loads for Buildings and Other Structures <br /> • Concrete Design <br /> o ACI 318-14 Building Code Requirements for Structural Concrete <br /> • Structural Steel Design <br /> o AISC 360-16 Specification for Structural Steel Buildings <br /> • Wood Design <br /> o ANS1/AWC NDS-2018 National Design Specification for Wood Construction with <br /> 2018 Supplement <br /> o ANSI/AWC SDPWS-2015 Special Design Provisions for Wind and Seismic <br /> COMPUTER PROGRAMS USED <br /> • Concrete Analysis and Design <br /> o Hilti PROFIS Engineering <br /> o Rebranding from "Anchor" to "Engineering"w/ move to the cloud <br /> engineering suite <br /> • Wood Analysis and Design <br /> ForteWEB (software by Weyerhaeuser) <br /> MATERIALS SPECIFICATIONS AND STRENGTHS ;.:; <br /> Concrete (normal weight) <br /> Slab-on-Grade, Concrete on Steel Deck, Curbs and Pads f = 4000 psi <br /> Reinforcing Steel <br /> Unless Noted Otherwise ASTM A 615, Grade 60 <br /> Structural Steel <br /> February 17, 2023 <br /> Page 5 <br />