Simpson Strong-Tie�,Wood Construction Connectors
<br /> Face-Mount Hangers - Solid Sawn Lumber (DF/SP)
<br /> -These products are available with additional corrosion ®For stainless-steel Many of these products are approved for installation
<br /> protection.For more information,see p.14. fasteners,see p.21. with Strong-Drives SD Connector screws.
<br /> See pp.348-352 for more information.
<br /> Dimensions(in.) Fasteners(in.) DF/SP Allowable Loads(lb.) Installed
<br /> Joist Model Mind Code
<br /> Size No. Ga. Max. Uplift Floor Snow Roof Cost Index Ref.
<br /> dW H B Header Joist (160) (100) (115) (125) (ICI)
<br /> >� Sawn Lumber Sizes
<br /> C
<br /> = U414 16 39/is 10 2 - (16)0.162 x 31h (6)0.148 x 3 990 2,305 2,610 2,815 Lowest
<br /> N 416 HUS412 14 39/ie 101h 2 - (10)0.162 x 31h (10)0.162 x 31h 3.435 2,635 2,985 3,220 19%
<br /> p - 14 3946 1311A° 21h Min. (20)0.162 x 31/2 (8)0.148 x 3 1,510 2,980 3,360 3,600 167%
<br /> HU416/HUC416
<br /> 14 39/+s 1311/1a 21h Max. (26)0.162 x 31h (12)0.148 x 3 2,015 3,870 4,365 4,695 178%
<br /> U66 16 51h 5 2 - (8)0.162 x 31h (4)0.148 x 3 535 1,150 1,305 1,410 -
<br /> CO 6x6 14 51h 4346 21h Min. (8)0.162 x 31h (4)0.162 x 31h 895 1,190 1,345 1,440
<br /> © HU66/HUC66
<br /> 14 51h 434s 21h Max. (12)0.162 x 31h (6)0.162 x 31/2 1,345 1,785 2,015 2,165
<br /> O
<br /> N U66 16 51h 5 2 - (8)0.162 x 31/2 (4)0.148 x 3 535 1,150 1,305 1,410
<br /> 6x8 HU68/HUC68 14 51h 5134e 21h Min. (10)0.162 x 31h (4)0.162 x 31h 895 1,490 1,680 1,800 -
<br /> ®
<br /> 14 51/2 513ie 2% Max. (14)0.162 x 31h (6)0.162 x 31h 1,345 2,085 2,350 2,530
<br /> U610 16 51h 8.5 2 - (14)0.162 x 31/2 (6)0.148 x 3 990 2,015 2,280 2,465
<br /> 6x10 HU610/HUC610 14 51h 7% 2% Min. (14)0.162 x 31h (6)0.162 x 31h 1,345 2,085 2,350 2,520
<br /> ®
<br /> 14 51h 7% 21h Max. (18)0,162 x 31h (8)0.162 x 31h 1,795 2,680 3,020 3,250 -
<br /> ® HUC0610-SDS 14 51h 9 3 - (12)1/4 x 21h SDS (6)1/4 x 2%SDS 2,325 4.680 5,185 5,185
<br /> HU612/HUC612 14 51h 93e 21h Min. (16)0.162 x 31h (6)0.162 x 31/2 1,345 2,385 2,690 2,880 -
<br /> ®
<br /> 6x12 14 51h 9% 21h Max. (22)0.162 x 31h (8)0.162 x 3% 1,795 3,275 3,695 3,970
<br /> © HUC0610-SDS 14 51h 9 3 - (12)1/4 x 21h SDS (6)1/4 x 21h SDS 1 2,325 4,680 1 5,185 5,185
<br /> ® HUC0612-SDS 14 51/2 11 3 - (14)1/4 x 2%SDS (6)1/4 x 21/2 SIDS 2,325 5,185 5,185 5,185 IBC,FL,LA
<br /> HU614/HUC614 14 51h 11% 21h Min. (18)0.162 x 31h (8)0.162 x 31h 1,780 2,680 3,025 3,240 6x14 -
<br /> 14 51h 11% 21h Max. (24)0.162 x 31h (12)0.162 x 31/2 2,695 3,570 4,030 4,335
<br /> ® HUCQ610-SDS 14 51/2 9 3 - (12)1/4 x 21h SDS (6)1/4 x 21h SDS 2,325 4,680 5,185 1 5,185 -
<br /> ® HUCQ612-SDS 14 51/2 11 3 - (14)1/4 x 21h SDS (6)1/4 x 21h SDS 2,325 5,185 5,185 5,185
<br /> HU616/HUC616 14 51/2 13% 21/2 Min. (20)0.162 x 31/2 (8)0.162 x 31h 1,780 2,980 3,360 3,600
<br /> �
<br /> 6x16 14 51h 13% 21h Max. (26)0.162 x 31/2 (12)0.162 x 31h 2,695 3,870 4,365 4,695
<br /> ® HUCQ612-SDS 14 51h 11 3 - (14)114 x 21h SDS (6)1/4 x 21/2 SDS 2,325 5,185 5,185 5,185 z
<br /> 14 71h 6% 21h Min. (10)0.162 x 31h (4)0.162 x 31/2 895 1,490 1,680 1,800
<br /> 8x8 HU88/HUC88 a
<br /> 14 71h fish 21h Max. (14)0.162 x 31h (6)0.162 x 31h 1,345 2.085 2,350 2,530
<br /> 14 71h 8% 21h Min. (14)0.162 x 31h (6)0.162 x 31h 1,345 2,085 2,350 2,520 • Lu
<br /> F
<br /> 8x10 HU810/HUC810
<br /> 14 71h 8% 21h Max. (18)0.162 x 31h (8)0.162 x 31/2 1,795 2,680 3,020 3,250 a
<br /> 8x12 HU812/HUC812 14 71h 1011s 21h Min. (16)0.162 x 31h (6)0.162 x 31h 1,345 2,385 2,690 2,880
<br /> 14 Ph 101h 21h Max. (22)0.162 x 31h (8)0.162 x 31h 1,795 3,275 3,695 3,970 0
<br /> Sx14 HU814/HUC814
<br /> 14 71h 117/a 21h Min. (18)0.162 x 31h (8)0.162 x 31h 1,780 2,680 3,025 3,240
<br /> � �
<br /> 14 Ph 117h 21h Max. (24)0.162 x 31h (12)0.162 x 31h 2.695 3,570 4,030 4,335 • o
<br /> N
<br /> Sx16 HU816/HUC816 14 71h 13% 21h Min. (20)0.162 x 31/2 (8)0.162 x 31/2 1,780 2,980 3,360 3,600
<br /> �
<br /> 14 71h 13% 21h Max. (26)0.162 x 31/i (12)0.162 x 31h 2,695 3,870 4.365 4,695 N
<br /> U
<br /> 1.Uplift loads have been increased for earthquake or wind loading with no further increase allowed. ti
<br /> Reduce where other loads govern.
<br /> 2.For minimum nailing quantity and load values,fill all round holes;for maximum nailing quantity and load values,
<br /> fill all round and triangular holes. •
<br /> 3.DF/SP loads can be used for SCL with an equivalent specific gravity of 0.50 or greater.
<br /> 4.Truss chord cross-grain tension may limit allowable loads in accordance with ANSI/TPI 1-2014. . •
<br /> Simpson Strong-Tie°Connector Selector°software includes the evaluation of cross-grain tension in °
<br /> its hanger allowable loads.For additional information,contact Simpson Strong-Tie. • H
<br /> 5.Fasteners:Nail dimensions are listed diameter by length.See pp.21-22 for fastener information. °
<br /> 6.Hangers with an"*"do not have an Installed Cost Index.
<br /> Codes:See p.11 for Code Reference Key Chart
<br /> 108
<br />
|