Simpson . ... Construction Connectors
<br /> Face-Mount Hangers — Solid Sawn Lumber (DF/SP)
<br /> -These products are available with additional corrosion ®For stainless-steel Many of these products are approved for installation
<br /> protection.For more information,see p.14. fasteners,see p.21. with Strong-Drive'SD Connector screws.
<br /> See pp.348-352 for more information.
<br /> Dimensions(in.) Fasteners(in.) DF/SP Allowable Loads(lb.) Installed
<br /> Joist Model Min./ Code
<br /> Size No. Ga. Max. Uplift Floor Snow Roof Cost Index Ref.
<br /> sN. W H B Header Joist (160) (100) (115) (125) (ICI)
<br /> d
<br /> ED Sawn Lumber Sizes
<br /> C
<br /> = U414 16 3'/ia 10 2 — (16)0.162 x 3% (6)0.148 x 3 990 2,305 2,610 2,815 Lowest
<br /> A4x16 HUS412 14 33/is 101h 2 — (10)0.162 x 31h (10)0.162 x 31h 3,435 2,635 2,985 3,220 19%
<br /> p 14 39AG 1311fc 21h Min. (20)0.162 x 31h (8)0.148 x 3 1,510 2.980 3,360 3,600 167%
<br /> -7 HU416/HUC416
<br /> C 14 3% 1311AG 21h Max. (26)0.162 x 31h (12)0.148 x 3 2,015 3,870 4,365 4,695 178%
<br /> U66 16 51h 5 2 — (8)0.162 x 31/z (4)0.148 x 3 535 1,150 1,305 1,410
<br /> 6x6 14 51h 4% 21h Min. (8)0.162 x 31h (4)0.162 x 31h 895 1,190 1,345 1 1,440
<br /> V © HU66/HUC66
<br /> 14 51h 06 21h Max. (12)0.162 x 31h (6)0.162 x 31/2 1,345 1,785 2,015 2,165
<br /> O
<br /> !A U66 16 51h 5 2 — (8)0.162 x 31h (4)0.148 x 3 535 1,150 1,305 1,410
<br /> 6x8 HU68/HUC68 14 51h 5"A6 21h Min. (10)0.162 x 31/2 (4)0.162 x 31h 895 1,490 1,680 1,800
<br /> ®
<br /> 14 51h 5"A6 21h Max. (14)0.162 x 3% (6)0.162 x 31h 1,345 2,085 2.350 2,530
<br /> U610 16 51h 8.5 2 — (14)0.162 x 31h (6)0.148 x 3 990 2,015 1 2,280 2,465
<br /> 6x10 HU610/HUC610 14 51h 7% 21h Min. (14)0.162 x 31h (6)0.162 x 31h 1,345 2,085 2,350 2,520
<br /> ©
<br /> 14 51h 7% 21h Max. (18)0.162 x 31h (8)0.162 x 31h 1,795 2,680 3.020 3,250
<br /> ® HUC0610-SDS 14 51h 9 3 — 1 (12)1/4 x 21h SDS (6)1/4 x 21h SDS 2,325 4,680 5,185 5,185
<br /> HU612/HUC612 14 51h 93fi 21h Min. (16)0.162 x 31h (6)0.162 x 31h 1.345 2,385 2,690 2.880
<br /> ©
<br /> 602 14 51h 93A 21h Max. (22)0.162 x 31/2 (8)0.162 x 31h 1,795 3,275 3.695 3,970
<br /> © HUCQ610-SDS 14 51h 9 3 — (12)114 x 21/z SDS (6)1/4 x 21h SDS 2,325 4,680 5,185 5,185
<br /> ® HUC0612-SDS 14 51h 11 3 — (14)1/4 x 21h SDS (6)1/4 x 21h SDS 2,325 5,185 5,185 5,185 IBC,FL,LA
<br /> HU614/HUC614 14 51h 11% 21h Min. (18)0.162 x 31h (8)0.162 x 31/z 1,780 2,680 3,025 3,240
<br /> 6x14 14 51h 11% 21h Max. (24)0.162 x 31h (12)0.162 x 31h 2,695 3,570 4,030 4,335
<br /> ® HUC0610-SDS 14 51/i 9 3 — (12)1/4 x 21h SDS (6)1/4 x 21h SDS 2,325 4,680 5,185 5,185
<br /> ® HUC0612-SDS 14 51h 11 3 — (14)1/4 x 21h SDS (6)1/4 x 21h SDS 2,325 5,185 5,185 5,185
<br /> HU616/HUC616 14 51h 13% 21h Min. (20)0.162 x 31h (8)0.162 x 31h 1,780 2,980 3,360 3,600
<br /> �
<br /> 6x16 14 51h 13% 21h Max. (26)0.162 x 31/i (12)0.162 x 31h 2,695 3,870 4,365 4,695
<br /> © HUC0612-SDS 14 51h 11 3 — (14)1/4 x 21h SDS (6)1/4 x 21/z SDS 2,325 5,185 5,185 5,185 1 • z
<br /> 14 Ph fish 21h Min. (10)0.162 x 31h (4)0.162 x 31h 895 1,490 1,680 1,800
<br /> 8x8 HU88/HUC88 a
<br /> 14 71h 6% 21h Max. (14)0.162 x 31h (6)0.162 x 31h 1,345 2,085 2,350 2,530 �
<br /> 14 71h 83A 21h Min. (14)0.162 x 31h (6)0.162 x 31/2 1,345 2,085 2,350 2,520 • F
<br /> 8x10 HU810/HUC810 14 71h 8% 21h Max. (18)0.162 x 31h (8)0.162 x 31h 1,795 2,680 3,020 3,250 o
<br /> 14 71h 101h 21h Min. (16)0.162 x 31h (6)0.162 x 31h 1,345 2,385 2,690 2,880
<br /> 8x12 HU812/HUC812 14 71h 101A 21h Max. (22)0.162 x 31h (8)0.162 x 31h 1.795 3,275 3,695 3,970 o
<br /> 14 71h 117A 21h Min.1 (18)0.162 x 31h (8)0.162 x 31h 1,780 2,680 3,025 3,240
<br /> 8x14 HU814/HUC814 U5
<br /> 14 Max. (24)0.162 x 31h (12)0.162 x 31h 2,695 3,570 4,030 4,335 o
<br /> N
<br /> 14 71h 135/e 21h Min. (20)0.162 x 31h (8)0.162 x 31h 1,780 2,980 3,360 3,600
<br /> 8x16 HU816/HUC816
<br /> 14 71h 135/e 21h Max. (26)0.162 x 31h (12)0.162 x 31h 2,695 3,870 4,365 4,695 • N
<br /> U
<br /> 1.Uplift loads have been increased for earthquake or wind loading with no further increase allowed.
<br /> Reduce where other loads govern.
<br /> 2.For minimum nailing quantity and load values,fill all round holes;for maximum nailing quantity and load values,
<br /> fill all round and triangular holes.
<br /> 3.DF/SP loads can be used for SCL with an equivalent specific gravity of 0.50 or greater.
<br /> 4.Truss chord cross-grain tension may limit allowable loads in accordance with ANSVTPI 1-2014. •
<br /> Simpson Strong Tie'Connector Selector'software includes the evaluation of cross-grain tension in •
<br /> its hanger allowable loads.For additional information,contact Simpson Strong-Tie. • ° H
<br /> 5.Fasteners:Nail dimensions are listed diameter by length.See pp.21-22 for fastener information.
<br /> 6.Hangers with an""do not have an Installed Cost Index.
<br /> Codes:See p.11 for Code Reference Key Chart
<br /> �V2,
<br /> 108
<br />
|