My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10101 7TH AVE SE BLDG 10 2025-12-12
>
Address Records
>
7TH AVE SE
>
10101
>
10101 7TH AVE SE BLDG 10 2025-12-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2025 11:51:38 AM
Creation date
10/21/2025 11:39:46 AM
Metadata
Fields
Template:
Address Document
Street Name
7TH AVE SE
Street Number
10101
Unit
BLDG 10
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Title: Wildreed Apartments <br /> Engineer: DEI <br /> DEI Project ID: 23-107 <br /> Project Descr: Deck Repair <br /> DIBBLE ENGINEERS INC <br /> Wood Column Project File:Wildreed Framing Checks.ec6 <br /> LIC#:KW-06014989,Build:20.23.2.14 DIBBLE ENGINEERS INC. (c)ENERCALC INC 1983-2022 <br /> DESCRIPTION: New 8x8 Posts (Check Bottom Level for Governing Gravity Loads) <br /> Code References <br /> Calculations per NDS 2018, IBC 2018, CBC 2019,ASCE 7-16 <br /> Load Combinations Used : IBC 2021 <br /> General Information <br /> Analysis Method Allowable Stress Design Wood Section Name 8x8 <br /> End Fixities Top&Bottom Pinned Wood Grading/Manuf. Graded Lumber <br /> Overall Column Height 10 ft Wood Member Type Sawn <br /> (Used for non-slender calculations) Exact Width 7.50 in Allow Stress Modification Factors <br /> Wood Species Douglas Fir-Larch <br /> Exact Depth 7,50 in Cf or Cv for Bending 1.0 <br /> Wood Grade No.1 n Cf or Cv for Com ressia 1.0 <br /> Area 56.250 in 2 P <br /> Fb+ 1,200.0 psi Fv 170.0 psi Ix 263.672 in^4 Cf or Cv for Tension 1.0 <br /> Fb- 1,200.0 psi Ft 825.0 psi ly 263.672 in^4 Cm:Wet Use Factor 1.0 <br /> Fc-Prll 1,000.0 psi Density 31.210 pcf Incising Factors: Ct:Temperature Fact 1.0 <br /> Fc-Perp 625.0 psi for Bending 0.80 Cfu:Flat Use Factor 1.0 <br /> E:Modulus of Elasticity.. . x-x Bending y-y Bending Axial for Elastic Modulus 0.95 Kf:Built-up columns 1.0 NDS 15.3.2 <br /> Basic 1,600.0 1,600.0 1,600.0 ksi Use Cr:Repetitive? No <br /> Minimum 580.0 580.0 Brace condition for deflection(buckling)along columns: <br /> X-X(width)axis: Unbraced Length for buckling ABOUT Y-Y Axis=10 ft,F <br /> Y-Y(depth)axis: Unbraced Length for buckling ABOUT X-X Axis=10 ft, H <br /> Applied Loads Service loads entered.Load Factors will be applied for calculations. <br /> Column self weight included : 121.914 Ibs*Dead Load Factor <br /> AXIAL LOADS . . . <br /> Beam Reaction from Second Floor Deck:Axial Load at 10.0 ft, D=0.4360, L= 1.501, S=0.6250 k <br /> Beam Reaction from Third Floor Deck:Axial Load at 10.0 ft, D=0.4360, L= 1.501, S=0.6250 k <br /> DESIGN SUMMARY <br /> Bending&Shear Check Results <br /> PASS Max.Axial+Bending Stress Ratio = 0.09979:1 Maximum SERVICE Lateral Load Reactions.. <br /> Load Combination +D+L Top along Y-'Y 0.0 k Bottom along Y-Y 0.0 k <br /> Governing NDS Forumla Comp Only,fc/Fc' Top along X-)( 0.0 k Bottom along X-X 0.0 k <br /> Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections... <br /> At maximum location values are. Along Y-Y 0.0 in at 0.0 ft above base <br /> Applied Axial 3.996 k for load combination: n/a <br /> Applied Mx 0.0 k-ft <br /> 0.0 k-ft Along X-X 0.0 in at 0.0 ft above base <br /> Applied My <br /> Fc:Allowable 7110.0 psi for load combination:n/a <br /> Other Factors used to calculate allowable stresses... <br /> PASS Maximum Shear Stress Ratio= 0.0:1 Bending Compression Tension <br /> Load Combination +0.60D <br /> Location of max.above base 10.0 ft <br /> Applied Design Shear 0.0 psi <br /> Allowable Shear 217.60 psi <br /> Maximum Reactions Note: Only non-zero reactions are listed. <br /> X-X Axis Reaction k Y-Y Axis Reaction Axial Reaction My-End Moments k-ft Mx-End Moments <br /> Load Combination @ Base @ Top @ Base @ Top @ Base @ Base @ Top @ Base @ Top <br /> D Only 0.994 <br /> +D+L 3.996 <br /> +D+S 2.244 <br /> +D+0.750L 3.245 <br /> +D+0.750L+0.750S 4.183 <br /> +0.60D 0.596 <br /> L Only 3.002 <br /> S Only 1.250 <br />
The URL can be used to link to this page
Your browser does not support the video tag.