<br /> Dimensions(in.) Fasteners(in.) DF/SP Allowable Loads(lb.) Installed
<br /> Joist Model Min./ Code
<br /> Size No. Ga. Max. Uplift Floor Snow Roof Cost Index Ref.
<br /> i W H B Header Joist (160) (100) (115) (125) (ICI)
<br /> Sawn Lumber Sizes
<br /> C
<br /> c0 U414 16 30AG 10 2 - (16)0.162 x 31h (6)0.148 x 3 990 2,305 2,610 2,815 Lowest
<br /> 4x16 HUS412 14 3•fie 10% 2 - (10)0.162 x 31h (10)0.162 x 31/2 3,435 2,635 2,985 3,220 19%
<br /> N
<br /> - 14 394e 1317/+e 21/2 Min. (20)0.162 x 31h (8)0.148 x 3 1,510 2,980 3,360 3,600 167%
<br /> HU416/HUC416
<br /> 14 385e 13"fie 21h Max. (26)0.162 x 31/2 (12)0.148 x 3 2,015 3,870 4,365 4,695 178%
<br /> U66 16 51h 5 2 - (8)0.162 x 3'h (4)0.148 x 3 535 1,150 1,305 1,410
<br /> CO 6x6 14 51h 4-% 21/2 Min. (8)0.162 x 31h (4)0.162 x 31h 895 1,190 1,345 1,440
<br /> © HU66/HUC66
<br /> 14 51/2 43A6 21/2 Max. (12)0.162 x 31/2 (6)0.162 x 31h 1,345 1,785 2,015 2,165
<br /> (0 U66 16 51h 5 2 - (8)0.162 x 31/2 (4)0.148 x 3 535 1,150 1,305 1,410
<br /> 6x8 HU68/HUC68 14 51h 513/16 21/2 Min. (10)0.162 x 31h (4)0.162 x 3% 895 1,490 1,680 1,800
<br /> ®
<br /> 14 51h 513/i6 21/2 Max. (14)0.162 x 31h (6)0.162 x 31/2 1,345 2,085 2,350 2,530
<br /> U610 16 j 51h 8.5 2 - (14)0.162 x 31h (6)0.148 x 3 990 2,015 2,280 2,465
<br /> 14 51h 7% 21h Min. (14)0.162 x 31h (6)0.162 x 31/2 1,345 2,085 2,350 2,520
<br /> ® 6x10 HU610/HUC610 14 51/2 7% 1 21/2 Max. (18)0.162 x 31h (8)0.162 x 31/2 1,795 2,680 3,020 3,250
<br /> ® HUC0610-SDS 14 51h 9 3 - 1 (12)1/4 x 21h SDS (6)'/4 x 21/2 SDS 2,325 4,680 5,185 5,185
<br /> 14 51h 9% 21h Min. (16)0.162 x 31/2 (6)0.162 x 31/2 1,345 2,385 2,690 2,880 -
<br /> ® HU612/HUC612 14 51h 9% 21/2 Max. (22)0.162 x 31h (8)0.162 x 31/2 1,795 3,275 3,695 3,970
<br /> 602
<br /> ® HUC0610-SDS 14 51/2 9 3 - (12)'A x 21/2 SDS (6)1/4 x 21/2 SDS 2,325 4,680 5,185 5,185
<br /> ® HUCQ612-SDS 14 51/2 11 3 - (14)1/4 x 21/2 SDS (6)1/4 x 21/2 SDS 2,325 5,185 5,185 5,185 IBC,FL,LA
<br /> 14 51/2 % 21h Min. (18)0.162 x 31/2 (8)0.162 x 31/2 1,780 2,680 3,025 3,240
<br /> 6x14
<br /> HU614/HUC614 14 51/2 11% 21h Max. (24)0.162 x 31h (12)0.162 x 31h 2,695 3,570 4,030 4,335
<br /> ® HUC0610-SDS 14 51h 9 3 - (12)1/4 x 21h SDS (6)1/4 x 21/2 SDS 2,325 4,680 5,185 5,185
<br /> ® HUCQ612-SDS 14 51h 11 3 - (14)114 x 21/2 SDS (6)'/4 x 21/2 SDS 2,325 5,185 5,185 5,185
<br /> HU616/HUC616 14 51h 133A 21h Min. (20)0.162 x 31h (8)0.162 x 31/2 1,780 2,980 3,360 1 3,600
<br /> 6x16 14 51h 13% 21h Max. (26)0.162 x 31/2 (12)0.162 x 31/z 1 2,695 3,870 4,365 4,695
<br /> ® HUCQ612-SDS 14 51h 11 3 - (14)1A x 21h SDS (6)1/4 x 21/2 SDS 2,325 5,185 5,185 5,185
<br /> 14 71h 6% 21/2 Min. (10)0.162 x 31h (4)0.162 x 31h 895 1,490 1,680 1,800
<br /> 8x8 HU88/HUC88
<br /> 14 71h 6% 21/2 Max. (14)0.162 x 31h (6)0.162 x 31h 1,345 2,085 2,350 2,530
<br /> 14 71/2 83A 21h Min. (14)0.162 x 31/2 (6)0.162 x 31h 1,345 2,085 2,350 2,520 • F
<br /> Sx10 HU810/HUC810 14 71h 8N 21/2 Max. (18)0.162 x 31h (8)0.162 x 31/2 1,795 2,680 3,020 3,250 o
<br /> 14 71/i 10% 21h Min. (16)0.162 x 31h (6)0.162 x 31h 1,345 2,385 2,690 2,880 fE
<br /> 8x12 HU812/HUC812
<br /> 14 71/2 10% 21/2 Max. (22)0.162 x 31/2 (8)0.162 x 31h 1,795 3,275 3,695 3,970 0
<br /> a.
<br /> 14 71h 117A 21h Min. (18)0.162 x 31/2 (8)0.162 x 31/2 1,780 2.680 1 3,025 3,240
<br /> 804 HU814/HUC814
<br /> 14 71h 117/a 21h Max. (24)0.162 x 31h (12)0.162 x 31h 2,695 3,570 4,030 4,335 �
<br /> N
<br /> r14 71h 136/6 21h Min. (20)0.162 x 31/2 (8)0.162 x 31h 1,780 2,980 3,360 3,600
<br /> 8x16 HU816/HUC816 N
<br /> 14 1 71h 13% 21h Max. (26)0.162 x 31h (12)0.162 x 31h 2,695 3,870 4,365 4,695 N
<br /> U
<br /> 1.Uplift loads have been increased for earthquake or wind loading with no further increase allowed.
<br /> Reduce where other loads govern.
<br /> 2.For minimum nailing quantity and load values,fill all round holes;for maximum nailing quantity and load values,
<br /> fill all round and triangular holes. • °
<br /> 3.DF/SP loads can be used for SCL with an equivalent specific gravity of 0.50 or greater.
<br /> 4.Truss chord cross-grain tension may limit allowable loads in accordance with ANSI/TPI 1-2014. • °
<br /> Simpson Strong-Tie"Connector Selector®software includes the evaluation of cross-grain tension in °
<br /> its hanger allowable loads.For additional information,contact Simpson Strong-Tie. • • H
<br /> 5.Fasteners:Nail dimensions are listed diameter by length.See pp.21-22 for fastener information. °