Laserfiche WebLink
BATMASTER /ABC Water Specialty <br /> 425-397-0275 <br /> 2918 Cavalero Rd <br /> Lake Stevens, WA 98258 <br /> BACKFLOW ExISTING H <br /> REMOVED <br /> PREY ENTER REPORT NEW REPLACED <br /> _ IMPAIRED OI<D S/N: <br /> PROPI'iRTY NAME Dhehe, Don PHONE 425-355-4835 <br /> CONTACT NAME Don Dhehe PRONE <br /> MAILING ADDRESS 4406 S 3rd Ave <br /> crrY Everett srxrLr WA zip 98203 <br /> PREVENTER ADDRESS 4406 S 3rd Ave Everett, WA 98203 _ <br /> WATER SUPPLIER Everett SERIAL# 391196 <br /> LOCATION In basement above boiler <br /> MAKE Watts MODEL LF009QT _ _ slzi: 1/211 <br /> TYPE ® RP ❑ RPDA [] RPDA-11 [] DC ❑ DCDA Q DCI)A-l[ [] PVB [7] SVR C] AVB AG <br /> HAZARD PROTECTED L_I PRIIMIS139 iSOLA ION IRRIGATION [] MP-SYSTEM ® MOILER tYlANt <br /> APPROVED: ® ASSEMBLY [K INSTALLATION ® ORIENTATION [] AIRGAP PIPCSVti in sr ARATioN 111 <br /> REDUCED PRESSURE ASSEMBLY PVItA/SVDA 114171AL TEST <br /> DOURLI;CHECK AIR INLET CIIRCI(VALVE PASSED <br /> CHECK III CIMCKIII TYPEII � nrlinPDlC( PRESS DROP. <br /> PROI! 7.8 TIGII•P IN IA1i.ED <br /> UROP: 1��I <br /> INITIAL MIN S PSID <br /> TEST REIdFF VALVE LEAKED MrN I Mn AWN I PSID MIN I PSI) DATE 03-1 1-24 <br /> RESULTS opu—)AT 3.4 OPENED <br /> MId2PSID CRECK02 _ FULLY FAILED SYSTEM PSi 83 <br /> RELIED VALVE: Tmirr DID PLOT DFTECOR METER <br /> PASSED FX FAILED F [ READING. <br /> i.BAKED A1IN I PSID <br /> NOTES <br /> REPAIRS <br /> PARTS <br /> REDi)CED PRMU E ASSEMBLY iPVBA/SVBA TEST <br /> CHECK 41 DOUBLE CHECK AFTER REPAIRS <br /> PRESS CdECIC#I <br /> DROP: TYPR H AIR INLET CIIECK VALVE, <br /> REPAIR MIN 5PSIn ll(;HT [j OPINMAT: WES%DROP: <br /> RESULTS RELIEF VAINE DATE <br /> OKWDAr: CHECK#2 FAIN I1*.M MIN IMir) MEN IPRID <br /> RRI,TR{+VALVIi MIN2PSID TIGHT OPIi.Y M PASSED ❑ <br /> PASSED ❑ PATi,6D "I'll <br /> "W <br /> GAUGES/N 03051796 MAKF./MODEL MID-WEST 845-5 CALIBRATION DATE 08-15-2023 <br /> in completing and submitting this test report,the tester certifies that the assembly was tosted and maintained in accordance with all applicable <br /> rules laws,codes and regulations of the state and waters stem using approved twin ui ment and approve testin yrocedures. <br /> IVY' AL TEST TEST AFTER REPAIRS <br /> B7798 <br /> t?STE I I {tIi TI!STFR SIGNATURE, THSTnR CERT# <br /> Kevin Nolasco 425-397-0275 <br /> TFSTFR NAME(PRIM'81)) TESTER NAME(PRINTFO) PHONE# <br /> 2918 Cavalero Rd Lake Stevens, WA 98258 batmaster9backilowservice.ne <br /> TESTER ADDRESS TESTPR ADDRESS EMAIL <br /> BATMASTER /ABC Water Specialty <br /> 1COMPANY NAME � COMPANY NAME ® WATER RES'[ORItit?'I <br /> -MORT RUGFIVED By(RUMSSLNTATI"OP ONVNIiR) RRPORT R1IGElV")Dy(RPf9r.4lElITA•I7 VE AP OWNIIR) 0 FOUND OFF,LEFT OFF <br />